Loading...
HomeMy WebLinkAbout134.43.1 - Proposed Septic DesignSOIL TEST DATE OF SOIL TEST APRIL 15 2C04 `_ SOIL TEST DONE BY SFk TSER EENGINEERING WITNESSED BY _I, -_QPHFRTY __y_-_ 03SMAMON HOLE 1 ELEV.=-88.80 03SMA1101 HOLE 2 ELEV.=_ 89.30 PERCOLATION RATE <, 2- MIN./INCH IN C2 HORIZON PERCOLATION RATE _< 2- MIN./!NCH AT 75 _ INCHES DEPTH HORiZi TEXTURE COLOR MOTT. OTHER 0-17 A LOAMY SAND 10YR5/3 10YR5/3 10 FT. MINIMUM FROM SLAB OR 17-29 B LOAMY SAND 10YR4/6 10YR4/6 29-50 Cl LOAMY SAND 10YR5/8 2.5YS/4 50-120 C2 FINE SAND 2.5Y6/4 2.5Y6/6 zii DEPTH HOR Z TEXTURE COLOR M0TT. OTHER 0-10 A LOAMY SAND 10YR5/3 10 FT. MINIMUM FROM SLAB OR 10-27 B LOAMY SAND 10YR4/6 27-52 Cl SANDY LOAM 2.5YS/4 52-120 C2 FINE SAND 2.5Y6/6 TOP OF FOUNDATION l' 20 FT. MINIMUM FROM CELLAR 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE ELEV. a E^a.00 - - 235 GREAT W''ESTERN ROAD 508- P. 0. BOX 713 398-3922 SOUTH _DENNIS, MASS. 02660 CLEAN SAND DATE JULY 22, 2004 CONCRETE COVERS 4" SCHEDULE 40 PVC PIPE MIN. PITCH 1/8" PER FL INSPECTION PORT LOAM AND SEED LAYER ' " REVISED A?�i ,�A � � ha''.t � 1 0r 1 1 1/8" TO 1J2" 18.50 4" CAST IRON PIPE MA A " MAX. WASHED STONE 89.80 VAX (OR EQUAL) MINIMUM 87.551d1N. NOTREQUIRED SLAB ELEV. _8B.50 - --- PITCH 1J4" PER FT. z FLOW LINE 92y/-��•'� 132'00.4 BR.80 0 ELEV. 10" 1 M!N_ T ELEV. a p 0 o ELEV. _ _87.25 _ ELEV. _87-� E - L VEL _ P 6" SUp. E/L�EtV.� = E9.3D_ ' . o l , � ` ti � -i a 10 ELEV. = 85.47 ---- LIQUID 0«LET BAFFLE _ _65.47 DISTRIBUT10N � ELEV. 4 FEET 14 INCHES - I ---� BOA Bt�t,-iO 5 FEET 19 INCHES TO BE PLACED ON FIRM BASE - - ETON CAPAC/7YfflL7RA7ORS V7H STONE z 6 FELT 24 INCHES ( ) TO BE WATER TESTED ,67 7 FEET 29 INCHES IN AN 1 NO WATER ENCOUNTERED AT _ F0 _120"- ELEV. _ __.7A NO WATER ENCOUNTERED AT �_12D _ ELEV. _ 20.10. 8 FEET 34 INCHES 1500 GALLON IF MORE THAN ONE OUTLET 1' X 4n' X 10_ 74ENCN FORMA /708 A��rr� (TO BE PLACED ON FIRM BASE) SOIL SSD! �T10 WELL IN A SEPTIC !` N1 L 1 I A ZONE 3/4" TO 1 1/2" CLEAN S I JT�f'•3 (ShiS, INDEX / DOUBLE WASHED STONE ADJUST FREE OF FINES & SILT / SYSTEM t� pry [^ USGS PROBABLE WATER TABLE ELEV. _ -___ SELVAGE DI 0 L S STEM PROFILE 07SERVED WATER TABLE ( / / ) ELEV. = NOT TO SCALE BOTTOM OF TEST HOLE ELEV. = • z.s DESIGN CALCULA11ONS \ / R NUMBER OF BEDROOMS 4 GARBAGE DISPOSAL UNIT NO 23 ��r•/"°'^� \ l M / TOTAL ESTIMATED FLOW - - N 9 ` r 1 110 CAL/BR./DAY X �' _ BR. 10. ALL ,_.SUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND (_ 0._ GAL./DAY A7 11UNIIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE REQUIRED SEPTIC TANK CAPACITY --Cr - GAL, REPLACED WTH SAND AS SPECIFIED IN 310 CMR 15.255:(3). ACTUAL SIZE OF SEPTIC TANK 1500 GAL. 1 X11. A NEGATIVE GRADE OF 3/4" PER FOOT AWAY FROM THE FOUNDATION SOIL CLASSIFICATION I- _ v / SHALL BE MAINTAINED FOR A MINIMUM OF 15'. DESIGN PERCOLATION RATE <3__ MIN./IN. R 12. A VARIANCE OF 7.2' IS REQUIRED FOR THE TOP OF FOUNDATION TO EFFLUENT LOADING RATE --0,7-4- GAL./DAY/S.F. \ N BE LESS THAN 2' ABOVE THE HIGH POINT IN ROAD. LEACHING AREA 626.33 SQ. FT. (11x46)+(59xvno/12) `l Q LEACHING CAPACITY (AREA X RATE) X148 GAL./DAY LOT 28 / J J 625.33 X 0.74 ytc U - / RESERVE LEACHING CAPACITY ,583.4@ GAL:/DAY 40,107.6 f S. F. / / �- cD ' 44. 3' - M 90.8 ' 1500 OA SNS ' pR0ED1.1G r w MOTES: SEPT,�LLINI M I I 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. 88.E t TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR 91.8 \- - - - - _ - I M ✓ / ' THE SUBSURFACE DISPOSAL OF SEWAGE. g9, �O ,. C9p)- ti 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO l gg. / �. I l�N / - ,, WTHIN 6" OF FINISHED GRADE. 8 / /_ l ' ___ /,• 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF W'IHSTANUING H-10 LOADING UNLESS THEY ARE U J?ER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOACtNG.SNALL BE // / ' I , USED UNDER OR WITWN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE SHALL : j �fJ BE MORTARED IN PLACE. 0.2 /�! / / / / 1 1'- 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE. WITH - \ DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO 96.9 OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR 54.16 /' ` i+� 1 X / IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS / DBC _ / / - / PRIOR TO COMMENCING WORK ON SITE.. ESOT 1 `, ; / / „� - `-t 7. CONTRACTOR IS TIS O VERIFY GRADES AND ELEVATIONS AS WELL AS T J SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER \ mo IMMEDIATELY. \ mo. ` / / ` / 96. t ( 8. PARCEL IS IN FLOOD ZONE C \ 89.5 ` / / l 134_ 43.. \ ` ✓ " 9. LOT IS SHOWN ON ASSESSORS MAP _ AS PARCEL s \ 1(�9p / • 90.9 \ , / ,, 4 APPROVED: BOARD OF HEALTH \ SQIL �� p0 / / / 1 I ' J„�kal - 1 \ �' .69.3 C4 eRsv 1 `" DATE AGENT Fr EVA mr ro' EXISTING SPOT ELEVATION xO.O ` `�9EJ� 9.9 EXISTING CONTOUR ----00---- �� �•' � ,,Y -J9.7 -FINAL SPOT ELEVATION - FINAL CONTOUR 00 Tp �- SO" TEST LOCATION to ' UTILITY POLE ra3 / / - TOWN WATER -V' W CATCH BASIN �O j ,i y' 75• f -+( I'�i GAS LINE0 G - (9gJ� .� L' '. -�iJ CESSPOOL - CLEANOUT -d C.O. 101.4 cus IC 6Ao po ®- �0s� l' PROPOSED SEPTIC PES JG r ;, FOR gL Y FRUSY� DAVENPORT REALTY LOC. 686 ROUTE 6A, WN 28 YARI.MUTH, MASS. 235 GREAT W''ESTERN ROAD 508- P. 0. BOX 713 398-3922 SOUTH _DENNIS, MASS. 02660 DATE JULY 22, 2004 SCALE 101.0 i 01.3 REVISED A?�i ,�A � � ha''.t � 1 0r 1 LOCATION MAP 4E 10 92y/-��•'� 132'00.4 EXISTING SPOT ELEVATION xO.O ` `�9EJ� 9.9 EXISTING CONTOUR ----00---- �� �•' � ,,Y -J9.7 -FINAL SPOT ELEVATION - FINAL CONTOUR 00 Tp �- SO" TEST LOCATION to ' UTILITY POLE ra3 / / - TOWN WATER -V' W CATCH BASIN �O j ,i y' 75• f -+( I'�i GAS LINE0 G - (9gJ� .� L' '. -�iJ CESSPOOL - CLEANOUT -d C.O. 101.4 cus IC 6Ao po ®- �0s� l' PROPOSED SEPTIC PES JG r ;, FOR gL Y FRUSY� DAVENPORT REALTY LOC. 686 ROUTE 6A, WN 28 YARI.MUTH, MASS. 235 GREAT W''ESTERN ROAD 508- P. 0. BOX 713 398-3922 SOUTH _DENNIS, MASS. 02660 DATE JULY 22, 2004 SCALE REVISED REVISED A?�i ,�A � � ha''.t � 1 0r 1 LOCATION MAP C.- S8 PROd�5947 ODk'C X5947 -SAS DY '".2..C`J4 S FETSEP, ENGINEERING