HomeMy WebLinkAbout134.59.1 - Proposed Septic Design (2). TOP OF FOUNDATION 20 FT. MINIMUM FROM CELLAR SOIL TEST 111.00 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE DATE OF SOIL TEST t�AN-IARY.16 00� ELEV. _0 CLEAN SAND SOIL TEST DONE BY TWEE R N INHERING CONCRETE "WITNESSED BY -A. VON HONE COVERS LOAM AND SEED r a SCHEDULE 40 PVC PIPE OBSERVATION HOLE 1 > LEV.- LO2ALO OBSERVATION HOLE 2 ELEV,-,-, 104.7 MIN. PITCH 1/8" PER fT. 2" LAYER OF PERCOLATION RATE_, 2 MIN./INCH AT5 INCHES ES PERCOLATION RATE < •2 DEPTH HORIZ 7EXNRE COLOR MOTT, OTHER 0-7O/A . 1/8" TO 1/2- NO ROOTS 7-34 B : " NO ', ROOTS 0250 MAX 'STONE VENT ;. 5.50 4"T IRO PIP 4 CAS 1 ROOTS & 100.25 MIN. NOT REQUIRED . POR EQUAL bIINIMUM 26-50 Cl COARSE SAND ,¢ 30% COBBLES ITCH 1 4") PER FT. C2 MEDIUM SAND g 1 CU. FT. OF a TEE CONCRETE i W FLOW UNE 99.50 ANCHOR ELEV. 105.50M N. o e 1LEV. 105 00LEVEL e 3 10'ELEV. 9517 [ ELEV. + �_ GAS ELEV. s 99. 6" SUMP ELEV. _ _Q a # BAFFLE -_�Z_ DISTRIBUTION ' i - LIQUID OUTLET _ ELEV. BOX �9.� 6 HIGH CAPACITY ONN INFILTRATORS WITH T I - I t, 4 FEET b FEET 4 N 1 INCHES 19 INCHES (TO 8E PLACED ON FIRM BASE) - TO BE WATER TESTED IF MORE THAN ONE OUTLET 11 X48 X 10' TRENCH FORMATION .17 DEPTH HORIZ 7EXNRE COLOR MOTT, OTHER 0-7O/A . SANDY LOAM 10YR3/3 NO ROOTS 7-34 B : LOAMY SAND 10YR5/8 NO ', ROOTS 4-120 C 'LOAMY SAND 2.5Y7/j LOAMY SAND 10195/6 MIN. NCH IN C HORIZON i r ' 1500 GALLON DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-10 0%A 'SANDY LOAM 10YR3/2` NO ', ROOTS 10-26 8 LOAMY SAND 10195/6 ROOTS & DATE JAN. 1 8, . 2002 SCALE ,l ", =Ct COBBLES ' 26-50 Cl COARSE SAND t0YR6/6' 30% COBBLES 50-132 C2 MEDIUM SAND 2.5Y7/4 2b7 COBBLES i 6 FEET 24 INCHES TO BE PLACED ON FIRM BASE WELL NIA NO WATER ENCOUNTERED AT 7 FEET 29 INCHES ( ) SOIL ABSORPTION r r--�- .ELEV:..�92pD NO WATER ENCOUNTERED AT J-72 ELEV.• 8 FEET 34 INCHES SEPTIC TANK • ZONE ' . _93 in 3/4 TO 1 7/2 CLEANM INDEX DOUBLE WASHED STONE SYSTEM JTE (SAS) ADJUST . FREE OF FINES & SILT .. LEGEND: DESIGN CALCU b . USGS PR08ABLE. WATER TABLE ELEV. a _ ,' LAT] NS I SEWAGE DISPOSAL SYSTEM PROFILE EXISTING SPOT ELEVATION OO 0 NUMBER of BEDROOMS 4 - OBSERVED WATER TABLE ( / / }ELEV. _ ;.' EXISTING CONTOUR - 00--- GARBAGE DISPOSAL UNIT NOT TO SCALE BOTTOM OF TEST HOLE ELEV. _92.44 _ FINAL SPOT ELEVATION TOTAL °ESTIMATED. OW } - FINAL CONTOUR-- ( 110 GAL AY X BR. I/D �_ ) .�Q_ GAL/DAY, 1 ' SOIL TEST LOCATION REQUIRED SEPTIC TANK CAPACITY _MQ_ GAL _ / i .. I Vy - » -- ` ` �' _ ✓ / / UTILITY PO E -0-- _ ACTUAL SIZE OF SEPTIC TANK _1_ ' GAL. • r ! / _ -� / / TOWN WA m..ty SOIL CLASSIFICATION _�_ . - t 3 - f '� CATCH BAST DESIGN PERCOLATION RATE N. GAS UNE - ccVJ. EFFLUENT LOADING. RATE S_ _ GAL/D �, _ r _ l _ T �✓ ` �` C.O. Q 7�_ 'GAL,/DAY/S.F. CLEAN OUT LEACHING AREA ¢2g•33 Sp: FT. 111.3 _ _ 1 K 117.5 \ ` CESSPOOL C.P.O - A11X48}F(59=10/12) LEACHING CAPACITY AREA X RATE lE) y 826.33 X 0.74( ) A4 GAL./DAY RESERVE LEACHING CAPACITY : �' �/" - J_ .-r .�-- J- � _•--- r- i� '. \ � t \ � _ .: _`� � � ' 1 1 7.6 _ , • .�. ��+.iQ GALI/DA?. _ ✓ • 109.6 \ A , NOTES. '. J % / f'Q 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM .TO b.E.P. vL 1: 5 AND THE TOWN OF .-.7ARMQUTH RULES AND r �//EJ\ /' / / / Q g • REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY.UNITS SHALL BE BROUGHT T0: \ \ yRAO. WITHIN 6" OF FINISHED GRADE. \ „� / y y / y ✓ 3. ALL COMPONENTS OF THE SANITARY SYSTEM 'SHALL BE CAPABLE OF LOT T 1 f ` \ / / WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER'OR`WITHIN , J L O 1 1 r /\ 112) / i / 1 G2.5 10 FT. 'OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE ,..5 �{ ' / �: USED UNDER 'OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO BRING -COVERS TO GRADE SHALL . S.F. /102:4 BE MORTAREDIN PLACE_ , X171 3 �{j101 i' y / 101.5 7 5. NO DETERMINATION HAS BEEN MADE AS TO COM1PtJANCE WITH, i \ - 5.4 570 S.F. y y / 6 n 1 \ \\ . \ ` , j DEEDED OR ZONING REGULATIONS. OWNER /. APPLICANT IS TO " \ / (10 / J 101.2 OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY.'., t i 3 1.25 A�FES / / 6.UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR' IS TO CALL''DIG-SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS \ \ Q \ / /' ` t10F) / PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS';WELL AS , ` \ �\ SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY .VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. S. -PARCEL -IS 4N -FLOOD ZONE C_- =`. . (� ✓ 9. LOT IS SHOWN ON ASSESSORS MAP 134 AS PARCEL I_ 591 J• 107: J 801L V \ \ . / / ✓ _ 5T 2 l \ �� ' / /� • 14.9 : / j \ \ O (� \ moo j a` " /I 100.U' 1G0:2 Jill �JK 1500 GALLON D. BOX % SEPTIC TANK \ P X00 / �i_-..� ' .� \ \ \ �q \ \oma j! ✓ aQ' SOIL v 1 • fi63 5-- TEST 1 tSj \ 96.5 - �7 ` �. 94.0 �, � �� oo � / � 48,7 LOT 2 99.0 \�96J 1.25 ACRES y. ( 91.E o� TEST 2 / MHB ,,` \ 96.E4 LOL \ L �S 1500 GAIL N v [-� / SOF JA4 EPTIC TAN 'I 100.4 / / VD. tH A. 8 DUMAS X69 PG. 192 y L r µ �X y No 619, ` I / .. O 1347 o: BQX.' QEo APPROVED. BOARD OF ,HEALTH 99.4. i / / - . - - - .. y,�`� - ITAR0, \ SOIL j6. 9 7.3 - TEST t UPL134 DATE AGENT Q S8 P,40J SJ/1-dd dw 3J11-OD.DWC.02002 SWEET5ER ENGINEERING z CYQ m V) z SETUCKET ROUTEE 5A LOCUS PROPOSED SEPTIC ' DESIGN FOR DUBLIN CONSTRUCTION LOC. LOT 1, #754 ROUTE 6A YARMOUTH,; MASS SF77M*j"SM LNGlli�Gr 235 GREAT WESTERN ROADI, 50$-P, 0.' SOX' 713 3983922 SOUTH DENNIS, MASS. 42660 - DATE JAN. 1 8, . 2002 SCALE ,l ", =Ct REv. OCT. 10, 2002 roB NO..5311-=0 '. EET 1 LOCATION ' MAP REv. - Q S8 P,40J SJ/1-dd dw 3J11-OD.DWC.02002 SWEET5ER ENGINEERING