Loading...
HomeMy WebLinkAbout125 Pawkannawkut Drive Site Plan100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR - 100 --- EXISTING CONTOUR 5.6 6.35.7 6.3 6.3 wi/ 98-39.1 SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) DESIGN FLOW: 3_ BEDROOMS (1t0 GPD) = 330 GPD USE A 330 GPD DESIGN FLOW Sr E LOCUS SEPTIC TANK: 330 GPD ( 2 ) = 65a USE A L52 -CL GALLON SEPTIC TANK LEACHING: SOUND NANTUCKET N/A SIDES: LOCUS MAP BOTTOM: 30 x 15 (.74) = 333 TOTAL: 450 S.F. 333 GPD USE 2 ROWS OF 4 STANDARD INF:L RATORS WITH 3' STONE AT SIDES 3.3' BETWEEN ROWS AND 2.5' AT ENDS APPROVED DATE BJARD OF HEALTH _ , MA LOT 7A N/F B. GREG 7.2 ,iXISTING !:OUSE 6. EXIST. DWELL. TO BE 7' REMOVED AND DISPOSED 6 9 AT AN APPROVED SITE RA1 F `CE 7.a 154"9' : 7.5 72 RAf1. FENCt¢.6 7.2'. 1 7.7 7.P X I( 50 72 V\., 53• 5.6 1 v 1r � b I� 10 T 1m rrt Z l F � C•^�I rxm 1 1 ml� 1. 53' lN, 7.81---' _JJvv SCR. GAR � PORCH 1 LOT 5A 7.2 1 11 12,900 ) (UPLA (ND) 1i!� r � INCE 5.8/7.4 ST C9 7. X I p5.t7. SHED >. 7.� LOT 5A N/F W. DESTEFANO FIRST FLOOR MIN. ELEV. 12.0' Sysr;,FM PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (f OT 0 SCALE) '4CLSS :OVER (WATERTIGHT) TO • 1 1 .0' 10.6 MINIMUM .75' OF CCVER OVER PRECAST WITH A 6" OF FIN. GRADE - 2% SLOPE REQUIRED OVER SYSTEM t_RUN IPE LEVEL -0.75' DOUBLE WASHED PEASTONE 9.0'f % FOR FIRST 2' 0.75' MIN - PROPOSED 1500 / 8.5 8.69' GALLON SEPTIC $.44' TANK (H- 10) GFF ��.15 0 8.08' . a.. BAFFLE 8.32' 0000 MIN$ 0.58' 1 o0 7.5' ( 2 X SLOPE) \__6' CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) DEPTH OF FLfIW 4 (X SLOPE) (� X SLOPE) TEE SIZES 3/4" TO 1 1/2" DOUBLE WASHED STONE INLET DEPTH - 10" OUTLET DEPTH a 14" FOUNDATION- 14' SEPTIC TANK 12' - D' BOX 9' LEACHING FACT ITY Z 6.2 5' REMOVAL OF UNSUITABLE SOIL REQUII)ED AROUND PERIMETER OF SYSTEM DONN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MEDIUM SAND. ENGINEER TO INSPECT i,ND CERTIFY REMOVAL ' C-- 7. 7. < PAVED 6.2 DRIVE (REMOVE) PROP.. CONCRETE RETAINING WALL AT ELEV. 8.5' , 1 , Invv�nrvwnn WA+ER GATE ELFY 6.81' ' " ! NG'✓D 1 1 111 6,r �_ PROPOSED DRIVEWAY 6t -" - ' 1 6.2 ' 6.4 1 A 6.9 - .. 1 4 - PROP. DWELLING 7.5 MIN, FIRST FLOOR ELEVATION = 12.0' EXISTING HOUSE <�r C:* 6 MIL POLY VIN'tL AND MASTIC R 5' -10"-� ON INSIDE OF R TAINING WALL (6) #3 BARS CONT. FOR HORIZONTAL REIIJFORCEMENT EL. 6.3' #3 BARS 16" O.C. FOR VERTICAL REINFORCEMENT 6" 4.3' SASE EL. SAND&GRAVEL FILL COMPACTED CONC. RET. WALL (NTS) 7 x A E x c 0 a USE ADJ. WATER ELEV. AT 2.5' (TIDALLY INFLUENCED) TEST HOLE LOGS ENGINEER: ARNE H. OJALA, PE WITNESS: AMY VON HONE, RS DATE 3/3/99 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# ELEV. 0" Q 6.4' LOAM FILL 12" PROP. DWELL. = 1778 SF (13.8% COVERAGE) WITH PROP. DECK = 439 SF (17.1% COVERAGE) EXIST DWELL. = 1929 SF (14.9% COVERAGE) WITH EXIST. PATIO = 408 SF (18.1% COVERAGE) SAND FILL 72" OBS. WATER 0.4' PEAT 120" I I -3.6' C MS 144" 1 1 -5.6' REQUIRED INSPECTIONS AND CERTIFICATIONS 1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION IS COMPLETE. 2. ENGINEER SHALL STAKE FOOTING PRIOR TO POURING 3. ENGINEER SHALL INSPECT FOOTING AND REBAR PRIOR TO POUTING OF WALL 4. ENGINEER SHALL INSPECT WHEN CLEAN FILL HAS BEEN PROPEFLY DEPOSITED 5. ENGINEER SHALL INSPECT AND CERTIFY SEPTIC COMPONENTS AFTER INSTALLATION ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT THE RETAINING WALL AND SEPTIC SYSTEM HAVE BEEN INSTALLED IN SUBSTANTIAL COMPLIANCE WITH THE APPROVED PLAN. ASSESSORS MAP 25 PARCEL 28 ZONING DISTRICT: R-25 YARD SETBACKS: FRONT = 30' SIDE = 15' REAR = 20' PLAN REF. - FLOOD ZONE: Al2 ELEV, 12 N TES: 1. DATUM IS NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC... 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. PUMP AND REMOVE EXISTING SEPTIC SYSTEM 12. DRYWELLS%TPENCHES REQUIRED FOR n ;OF Rt; 4 O.. -F .SITE PLAN OF #125 PAWKANNAWKUT DRIVE IN THE TOWN OF: (SOUTH) YARMOUTH PREPARED FOR: BONNE BROWNING 20 0 20 40 60 SCALE: 1" = 20' DATE: JUNE 21, 2001 REV 3/25/02 (HSE) P.L.S. DA TE o0 508-362-4511 lox 506 762-9800 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmouth, ma. 02675 ROOM 28'�� 1 Sr E LOCUS � LEWIS POND SOUND NANTUCKET LOCUS MAP SCALE: NTS ASSESSORS MAP 25 PARCEL 28 ZONING DISTRICT: R-25 YARD SETBACKS: FRONT = 30' SIDE = 15' REAR = 20' PLAN REF. - FLOOD ZONE: Al2 ELEV, 12 N TES: 1. DATUM IS NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC... 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. PUMP AND REMOVE EXISTING SEPTIC SYSTEM 12. DRYWELLS%TPENCHES REQUIRED FOR n ;OF Rt; 4 O.. -F .SITE PLAN OF #125 PAWKANNAWKUT DRIVE IN THE TOWN OF: (SOUTH) YARMOUTH PREPARED FOR: BONNE BROWNING 20 0 20 40 60 SCALE: 1" = 20' DATE: JUNE 21, 2001 REV 3/25/02 (HSE) P.L.S. DA TE o0 508-362-4511 lox 506 762-9800 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmouth, ma. 02675