HomeMy WebLinkAbout205 Pine Grove Road Proposed Septic Design 2J BENCHMARK TOP OF FOUNDATION ELEV. _ ��•� (NGVD) 4" SCHEDULE 40 PVC PIPE 20 FT. MINIMUM FROM CELLAR MIN. PITCH 1/8" PER FT.- IINIMUM FROM SLAB OR CRAWLSPACE 2 PRESSURE PIPE 150 PSI MINIMUM ELEV. a _ COVERS %� -Z- 6. 1 I CLEAN SAND 2" LAYER OF 1/8" TO 1/2" 1188 MAX WASHED STONE VENT 9.43 MIN. i 1 CU. FT. OF •• r CONCRETE ANCHOR PUMP SWITCHES DETAIL 3,01] INUNDATION) 4" CAST IRON PIPE 2000 GALLON SEPTIC TANK (H-20) 1 i 9.2 1000 GALLON PUMP CHAMBER (H-20) WEIGHT OF WATER DISPLACED PROPOSED SEPTIC DESIGN FOR GILBERT DESROCHERS WEIGHT OF WATER DISPLACED I 6 X 11 X 7.33 X 64 30,962 LBS. 5.25 X 9 X 6 X 64 18,144 LBS. WEIGHT OF TANK PER MANUFACTURER (OR EQUAL) MINIMUM PITCH 1/4' PER FT. WEIGHT OF TANK PER MANUFACTURER 14,500 LBS. WEIGHT OF 12" CONCRETE 20' WEIGHT OF WATER IN SUMP o o _ - o • >0 ° 8.17 X 4.42 X 0.83 X 62.5 1,873 LBS. ALARM ON 10YR5/8 WEIGHT OF 10" CONCRETE SCALE 1" = 20' 1 L IL 868 LBS. 8.17 X 4,42 X 0.83 X 135 4,046 LBS. ELEV. a 6' SUMP ELEyL= _Q8_ ° e - -- WCD ELEV. a 7.35 _ 2,275 LBS. 17. 1.32 TO TITLE 5 AND YARMOUTH REGULATIONS: A. SOIL ABSORPTION SYSTEM ONLY 4• ABOVE ADJUSTED FLOW LINE i 0.,"_ 15 7/8' PUMP ON 800 ELEV. = ELEV. 0 __ MIN. 3/8' DDISTRIBUTION BOX __dlfl_ 6 HIGH CAPACITY INFILTRATORS WITH STONE IN AN 4'� 15 5/8" 1.30 ELEV. a 7_35_ GAS BAFFLE HOLE BE WATER TESTED 11' X 48' X 10• TRENCH FORMATION ? WELL M1W 29 PUMP OFF ELEV. s 7.10_ , (TO BE PLACED ON FIRM BASE) SOIL ABSORPTION n ZONE A INDEX 7.6 10" 0.83• CHECK 3/4" TO 1 1/2` ADJUST IL LIQUID OUTLET - -- -- VALVE WASHED STONE SYSTEM (SAS) 10' 0.83' CONCRETE DFPTH TEE (TO BE PLACED ON FIRM BASE) 4 FEET 14 INCHES 5 FEET 19 INCHES 2000 GALLON MYERS MHV 4 OR 5 PUMP 3• 6 FEET 24 INCHES ( OR EQUAL) USGS PROBABLE WATER TABLE ELEV. = 7 FEET 8 FEET 29 INCHES 34 INCHES SEPTIC TANK CHAMBER 10" CONCRETE OBSERVED WATER TABLE (6/26/01) ELEV. Z-0 0.9� BOTTOM OF TEST HOLE ELEV. _ LEGEND: 12" CONCRETE PUMP CHAMBER CALCULATIONS: EXISTING SPOT ELEVATION 00„0 ELEV. AT INVERT INLET 7_00 EXISTING CONTOUR ----00---- ELEV. AT ALARM ON SEWAGE DISPOSAL SYSTEM PROFILE ELEV. AT PUMP ON b_15, 5.13 REQUIRED FLOW PER CYCLE .25 X �Q = _�14_ GAL./CYCLE FINAL SPOT ELEVATION 0 . FINAL CONTOUR VOLUME PER CYCLE 710_ GAL/CYCLE /7.48 GAL./CU. FT. = 14_71_ CU. FT./CYCLE SOIL TEST LOCATION $- NOT TO SCALE ELEV.4.66 3.83 VOLUME OF WATER IN PIPE 3.14 X 0.00694 X 67_- FT. _ _1-_ CU. FT. UTILITY POLE -o- CAPACITY OF SEPTIC TANK BOTTOMTOFUNSIDEFPUMP CHAMBER BOTTOM OF INSIDE PUMP CHAMBER _9_0o TOTAL MINIMUM VOLUME PER CYCLE _ , WCU. FT. 0.47 FT. (1000 G.S.T.) TOWN WATER -WSW 5XiOX(5.33-1.00)X7.48 a 1_819.42 GALLONS BOTTOM OF OUTSIDE PUMP CHAMBER 2.50 DISCHARGE _1412 CU. FT. / 34.67 CU.FT./FT. STORAGE CAPACITY ( 449_ CAL./DAY /7.48 GAL./CCU.FT./34.67 CU.FT./FT. - 1.70 FT. CATCH BASIN 10Y G\"7 _LZQ_ REQUIRED 1.65 PROVIDED GAS LINE CESSPOOL 0CP. CLEANOUT C.O. DRIVE PROPOSED ,GARAGE /' PUMP CHAMBE AREA = 15,924 SO. FT. �i- x 9.3 w 2000 GALLON SEPTIC TANK x 9.7 /x.10.0 PSE DECK ' ry 59� SOIL I NEST BUOYANCY CALCULATIONS: (FULL INUNDATION) 10.08. 2000 GALLON SEPTIC TANK (H-20) 1 i 9.2 1000 GALLON PUMP CHAMBER (H-20) WEIGHT OF WATER DISPLACED PROPOSED SEPTIC DESIGN FOR GILBERT DESROCHERS WEIGHT OF WATER DISPLACED 6 X 11 X 7.33 X 64 30,962 LBS. 5.25 X 9 X 6 X 64 18,144 LBS. WEIGHT OF TANK PER MANUFACTURER 25,080 LBS. WEIGHT OF TANK PER MANUFACTURER 14,500 LBS. WEIGHT OF 12" CONCRETE O WEIGHT OF WATER IN SUMP 7.5YR4/6 5 X 10 X 1 X 135 6,750 LBS. 8.17 X 4.42 X 0.83 X 62.5 1,873 LBS. EXCESS WEIGHT TO OFFSET FLOTATION 10YR5/8 WEIGHT OF 10" CONCRETE SCALE 1" = 20' 1 25080+6750-30692 868 LBS. 8.17 X 4,42 X 0.83 X 135 4,046 LBS. EXCESS WEIGHT TO OFFSET FLOTATION wv 1OT -- WCD 14500+1873+4046-18144 2,275 LBS. 17. VARIANCES TO TITLE 5 AND YARMOUTH REGULATIONS: A. SOIL ABSORPTION SYSTEM ONLY 4• ABOVE ADJUSTED WATER TABLE X 9.0 I x 8.9 ADDITION i i 9.8 HORIZ 10.08. COLOR 1 i 9.2 g38 0 V PROPOSED SEPTIC DESIGN FOR GILBERT DESROCHERS a 0-8 O/E J 10YR6/1 NO ROOTS 10.0 O EXISTING OWE LUNG 7.5YR4/6 .0 p I >k 9.3 4 BEDROOMS Cl MEDIUM SAND 10YR5/8 SCALE 1" = 20' 1 REV. AUG. 21, 200155e 9,76' - wv 1OT -- WCD LOCATION MAP REv. AUG. 30, 2001 J I ADDITION i i 9.8 1NOF T. A. DUMAS SOIL TEST DATE OF SOIL TEST JUNE_26, 2001 _ SOIL TEST DONE BY SW'EEISER ENGINEERING WITNESSED BY L_MULKEEN OBSERVATION HOLE 1 ELEV.=9.60 PERCOLATION RATE < 2 MIN./INCH AT 36 INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER PROPOSED SEPTIC DESIGN FOR GILBERT DESROCHERS 0-8 O/E MEDIUM SAND 10YR6/1 NO ROOTS 8-12 B LOAMY SAND 7.5YR4/6 i ROOTS 12-106 Cl MEDIUM SAND 10YR5/8 SCALE 1" = 20' 1 REV. AUG. 21, 200155e ND' 5147-00 LOCATION MAP REv. AUG. 30, 2001 SHEET 1 OF 1� i 1NOF T. A. DUMAS SOIL TEST DATE OF SOIL TEST JUNE_26, 2001 _ SOIL TEST DONE BY SW'EEISER ENGINEERING WITNESSED BY L_MULKEEN OBSERVATION HOLE 1 ELEV.=9.60 PERCOLATION RATE < 2 MIN./INCH AT 36 INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER PROPOSED SEPTIC DESIGN FOR GILBERT DESROCHERS 0-8 O/E MEDIUM SAND 10YR6/1 NO ROOTS 8-12 B LOAMY SAND 7.5YR4/6 ROOTS 12-106 Cl MEDIUM SAND 10YR5/8 SCALE 1" = 20' 1 WATER ENCOUNTERED AT 93" ELEV. m 2.05 DESIGN CALCULATIONS NUMBER OF BEDROOMS 4_ GARBAGE DISPOSAL UNIT NO TOTAL ESTIMATED FLOW (110 GAL/BR./DAY X 4 BR.) 440 GAL./DAY REQUIRED SEPTIC TANK CAPACITY D3E GAL ACTUAL SIZE OF SEPTIC TANK -ZQ-0-0 GAL. CAPACITY OF SEPTIC TANK 1619 GAL. SOIL CLASSIFICATION _J._ DESIGN PERCOLATION RATE <_�_ MIN./W. EFFLUENT LOADING RATE -D,74- GAL./DAY/S.F. LEACHING AREA 12LM SQ. FT. (11 X48)+(59X2X10/12) LEACHING CAPACITY (AREA X RATE) 483_48 GAL/DAY 626.33 X 0.74 RESERVE LEACHING CAPACITY 463_48 GAL/DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN OF YAR TK RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT, OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS, 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AU OORIiY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE' AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. 8. PARCEL IS IN FLOOD ZONE B do ARCLU) 9. LOT IS SHOWN ON ASSESSORS MAP _25 AS PARCEL RMAX6 10. PUMP- AND ALARM ARE TO BE ON SEPERATE .CIRCUITS. 11. ALARM IS TO BE BOTH AUDIO AND VISUAL 12. A ZABEL A1800 FILTER IS TO BE INSTALLED. 13. AN ELECTRIC PERMIT IS REQUIRED TO WIRE PUMP AND ALARM. 14. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE REPLACED WITH MATERIAL AS SPECIFIED IN 310 CMR 15.255:(3). 15. SEPTIC TANK AND PUMP CHAMBER ARE TO BE WATERPROOFED AT THE MANUFACTURER. 16. EXISTING CESSPOOLS ARE TO BE PUMPED AND REMOVED. APPROVED: BOARD OF HEALTH DATE � AGENT Imb- i'/3Qlr-]aa 1.1 QW Z o U W _Z o LOCUS SOUTH SHORE PROPOSED SEPTIC DESIGN FOR GILBERT DESROCHERS PROJECT LOCAT ON 205 PINE GROVE ROAD S.Y. SWEETSER ENGINEERING 235 GREAT WESTERN ROAD 508- P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 DATE JUNE 27, 2001 SCALE 1" = 20' 1 REV. AUG. 21, 200155e ND' 5147-00 LOCATION MAP REv. AUG. 30, 2001 SHEET 1 OF 1� Imb- i'/3Qlr-]aa 1.1