HomeMy WebLinkAbout18 Pilgrim Road Site PlanACCESS COVERS MUST BE WITHIN
6" OF FINISH GRAD
13.0 FIRST 2' TO
BE LEVEL?
GAS
INSPECTION
r PORT
3.3-
16
.3"
6 OUTLET 25 QUICK 4 PLUS STANDARD LP 6.O±. 5.0 MIN BY DRIVE BOTTOM OF LEACH CHAMBER: 6.9 C TANK REO UI RED: F. SEE SITE PLAN.
V D -80X 330 G.P.D. X 200x - 660 GAL.
INFILTRATOR CHAMBERS IN BED FORMATION 4o MIL Pocr AREA HIGH GROUND WATER: I.82 SEPTIC TANK PROVIDED: 1500 GAL. MIN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND
1500 GAL H-20 VAPOR BARRIER OBSERVED GROUND WATER: 1.45
SEPTIC TANK 6' MAINTENANCE OF THE SEPTIC SYSTEM SHALL
CRUSHED STONE OR a BOTTOM OF TEST HOLE •l: 0.7
COMPACTED BASE SOIL ABSORPTION SYSTEM REQUIRED: CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL
AREA HIGH THIS LOT FALLS WITHIN 200' OF TIDAL DESIGN PERC RATE ( 5 MIN/INCH BOARD OF HEALTH REGULATIONS.
PROFILE : Nor TO SCALE \ GROUNDWATER. EL -1.82 (2.a N6Y'))WATERS. HISTORIC HIGH GROUNDWATER SOIL TEXTURAL CLASS - I
VARIANCES REOUI RED :
TITLE 5. MAXIMUM FEASIBLE COMPLIANCE
SECTION 15.211:(1) MINIMUM SETBACK DISTANCES
10' IS REOUIRED BETWEEN THE SEPTIC TANK AND THE
FOUNDATION. 7' IS PROVIDED. A 3' VARIANCE IS
REQUESTED.
20' /S REQUIRED BETWEEN THE SOIL ABSORPTION SYSTEM
AND THE FOUNDATION. ll' IS PROVIDED TO A CRAWLSPACE.
A 9' VARIANCE IS REQUESTED.
a.7_ 1
BY. TOP OF CB
EL -5.6t NAVD 88
SOIL REMOVAL
SEE NOTE 10.
�f
ENTIRE LOT FALLS WITHIN
FLOOD ZONE AE (EL 12)
LEWIS BAY 1\ J` /�J
L OCUS MA P // O 10 20 40
USED FOR DESIGN IS EL 1.82 NAVD 88 EFFLUENT LOADING RATE - 0.74 GPD/SF 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER
GROUNDED 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER
GROUNDWATER. EL -1.45 (2.4J NGYD) (2• B NGVD 291 THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH -
+9.9 OVICK 4 CHAMRFR_ PROVIDEp • 25T
CLEAN SAND BACKFILL
AROUND AND 2' OVER CHAMBERS
/ F �
r �\
F) STING DWELL !h'^,
ND GARAGE TO OF
REMOVED
�\ LEGEND
CB CONCRETE BOUND
-W- WATER LINE
O HYDRANT
\ -G- GAS LINE
\ - OHW- OVER HEAD WIRES
B.r �t LIGHT POST
--E- UNDERGROUND ELECTRIC LINE
-T- UNDERGROUND TELEPHONE LINE
- CTV- UNDERGROUND CABLEVISION LINE
x-40.4 SPOT ELEVATION
....... •40....... EXISTING CONTOUR
40 PROPOSED CONTOUR
.. QUICK 4 PLUS STANDARD LP
S ANDING H-20 WHEEL LOADS.
INFILTRATOR CHAMBERS. 100'x 4.73 SF/FT -
9" MINIMUM.
3' MAXIMUM COVER
INVERT ELEVATIONS
5.
- DESIGN CRITERIA:
GENERAL NO TES :
CLEAN SAND BACKFILL
INVERT AT BUILDING:
9.0
DESIGN FLOW: 2 BEDROOMS. DESIGN FOR
-AROUND AND 2' OVER CHAMBERS
INVERT IN SEPTIC TANK:
8.5
3 BEDROOMS MINIMUM AT 110 G.P.D. PER
I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION
8.0 TOP OF WALL
INVERT OUT SEPTIC TANK:
8.25
BEDROOM EQUALS 330 G.P.D.
OF THE SEWAGE DISPOSAL SYSTEM AND PERMITTING
INVERT IN DIST. BOX:
7.47
PURPOSES ONLY.
BLOCK RETAINING
5 MALL. TO BE APPROVED
INVERT OUT DIST. 80X:
7.3
NO GARBAGE GRINDER
7.
BY ENGINEER
INVERT IN LEACH CHAMBER:
7.18
SEPT 1
2. VERTICAL DATUM IS NAVD 88. FOR BENCH MARKS
6 OUTLET 25 QUICK 4 PLUS STANDARD LP 6.O±. 5.0 MIN BY DRIVE BOTTOM OF LEACH CHAMBER: 6.9 C TANK REO UI RED: F. SEE SITE PLAN.
V D -80X 330 G.P.D. X 200x - 660 GAL.
INFILTRATOR CHAMBERS IN BED FORMATION 4o MIL Pocr AREA HIGH GROUND WATER: I.82 SEPTIC TANK PROVIDED: 1500 GAL. MIN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND
1500 GAL H-20 VAPOR BARRIER OBSERVED GROUND WATER: 1.45
SEPTIC TANK 6' MAINTENANCE OF THE SEPTIC SYSTEM SHALL
CRUSHED STONE OR a BOTTOM OF TEST HOLE •l: 0.7
COMPACTED BASE SOIL ABSORPTION SYSTEM REQUIRED: CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL
AREA HIGH THIS LOT FALLS WITHIN 200' OF TIDAL DESIGN PERC RATE ( 5 MIN/INCH BOARD OF HEALTH REGULATIONS.
PROFILE : Nor TO SCALE \ GROUNDWATER. EL -1.82 (2.a N6Y'))WATERS. HISTORIC HIGH GROUNDWATER SOIL TEXTURAL CLASS - I
VARIANCES REOUI RED :
TITLE 5. MAXIMUM FEASIBLE COMPLIANCE
SECTION 15.211:(1) MINIMUM SETBACK DISTANCES
10' IS REOUIRED BETWEEN THE SEPTIC TANK AND THE
FOUNDATION. 7' IS PROVIDED. A 3' VARIANCE IS
REQUESTED.
20' /S REQUIRED BETWEEN THE SOIL ABSORPTION SYSTEM
AND THE FOUNDATION. ll' IS PROVIDED TO A CRAWLSPACE.
A 9' VARIANCE IS REQUESTED.
a.7_ 1
BY. TOP OF CB
EL -5.6t NAVD 88
SOIL REMOVAL
SEE NOTE 10.
�f
ENTIRE LOT FALLS WITHIN
FLOOD ZONE AE (EL 12)
LEWIS BAY 1\ J` /�J
L OCUS MA P // O 10 20 40
USED FOR DESIGN IS EL 1.82 NAVD 88 EFFLUENT LOADING RATE - 0.74 GPD/SF 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER
GROUNDED 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER
GROUNDWATER. EL -1.45 (2.4J NGYD) (2• B NGVD 291 THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH -
+9.9 OVICK 4 CHAMRFR_ PROVIDEp • 25T
CLEAN SAND BACKFILL
AROUND AND 2' OVER CHAMBERS
/ F �
r �\
F) STING DWELL !h'^,
ND GARAGE TO OF
REMOVED
�\ LEGEND
CB CONCRETE BOUND
-W- WATER LINE
O HYDRANT
\ -G- GAS LINE
\ - OHW- OVER HEAD WIRES
B.r �t LIGHT POST
--E- UNDERGROUND ELECTRIC LINE
-T- UNDERGROUND TELEPHONE LINE
- CTV- UNDERGROUND CABLEVISION LINE
x-40.4 SPOT ELEVATION
....... •40....... EXISTING CONTOUR
40 PROPOSED CONTOUR
.. QUICK 4 PLUS STANDARD LP
S ANDING H-20 WHEEL LOADS.
INFILTRATOR CHAMBERS. 100'x 4.73 SF/FT -
!< 473 S.F. x 0.74 - 350 GPD
5.
ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR
APPROVED EQU4L.
SOIL TEST PIT DATA&
6.
SEPTIC TANK AND D -BOX SHALL BE REINFORCED
INDICATES IU INDICATES
PERCOLATION = OBSERVED
PRECAST CONCRETE OR APPROVED POLYETHYLENE.
TEST - GROUNDWATER
BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER
TP of
TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE
O• HORIZON TEXTURE COLOR 7.2
OUTLET.
A LOAMY IOYR
SAND 3/3
7.
BEFORE CONSTRUCTION CALL 'DIG -SAFE'.
22 - - - - - - - - S.4
1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT.
8 LOAMY IOYR
SAND 5/8
FOR LOCATION OF UNDERGROUND UTILITIES.
30' ___ _ _ _ _ ___ _____ 4.7
C1 COARSE IOYR
SAND AND 5/8
8.
SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE
GRAVEL
DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION
OF THE SYSTEM TO ALLOW FOR SCHEDULING OF THE
42'
CONSTRUCTION INSPECTIONS.
69 1.45
9.
EXISTING CESSPOOLS TO BE LOCATED. PUMPED DRY.
REMOVED AND BACKFILLED.
78" 0.7
10.
ALL UNSUITABLE MATERIAL IA 6 B HORIZONS)
DATE: JULY 16. 20/4
TEST BY: STEPHEN HAAS
ENCOUNTERED BELOW THE INVERT OF THE LEACHING
WITNESSED BY: AMY VONHONE
FACILITY TO BE REMOVED FOR A DISTANCE OF 5'
PERC RAic: i 2
AROL-1m) AND kEPLACEO WITH SAND IN ACCORDANCE
WITH TITLE S.
f/.
NO DETERMINATION HAS BEEN MADE AS TO
14. ALL SURFACE RUNOFF TO BE DIRECTED TO SWALES
COMPLIANCE WITH DEED RESTRICTIONS OR ZONING
ALONG THE PROPERTY LINE.
REGULATIONS. IT SHALL REMAIN THE CLIENTS
RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL
15. ALL ROOF RUNOFF TO BE DIRECTED TO SUITABLY
PERMITS. VARIANCES ETC. FOR THIS PROJECT.
SIZED DRYWELLS OR STONE TRENCHES ALONG THE
DRIP LINE.
12.
ANY RETAINING WALL SHOWN ON THIS PLAN IS FOR
LOCATION ONLY AND SHALL BE DESIGNED IN
I THE DRIVEWAY SHALL BE CONSTRUCTED OF PERVIOUS
ACCORDANCE WITH STANDARD PRACTICE.
MATERIALS SUCH AS CRUSHED STONE. GRAVEL.
SEASHELLS OR OTHER SIMILAR MATERIALS. THIS IS
l3.
IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY
AN ON-GOING. IN PERPETUITY CONDITION THAT DOES
TO HAVE THE PROPOSED BUILDING FOUNDATION
NOT EXPIRE WITH ISSUANCE OF THE CERT OF COMP.
li
DESIGNED TO ACCOUNT FOR THE EXISTING GRADE
AND SOIL CONDITIONS AT THE LOCATION OF THE
PROPOSED BUILDING.
S l TE' PLAN OF 'LAND
18 PILORIM ROAD. MAP 29. PARCEL 121
WEST YARMOUTH. MA.
PREPARED F O R :
RAYMOND CA TALON l
SCALE": 1- 20 JULY 2 1 . 2014
REVISED: AUGUST 6. 20/4 (NOTES. DRIVEWAY)
REVISED: AUGUST 13. 2014 (SEPTIC NOTES)
STEPHEN A. HAAS
ENGINEERING, INC
923 Route 6A
Yarmouthport MA. 02675
(SOB) 362-8 1 32
JOB NO: 14-042