HomeMy WebLinkAbout118 Pleasant Street Sewage Disposal Sytem DesignSOIL TEST PIT DATA: 8/10/2000 SEPTIC TANK DETAIL: 2,000; jALLON H-20 DISTRIBUTION BOX' DETAIL: NOT TO SCALE LEACHING DETAIL: NOT TO SCALE H-20 LOADING
H-20 LOADING
Z,x
NOT" TO SCALE 1 32'
TEST PIT, L_ NOTES: 1. SEPTIC TANK SHALL BE STEEL 5. INLET AND OUTLET TEES TO BE CAST IRON: MREMOVABLE�OVERw DUTY N0. OF OUTLETS g
NF CRETE SCHED, 40 PVC OR CAST -IN-PLACE CONCRETE.
MORTAR.SLOPE OF PIPE: EXCEEDS 0.08 FT./FT OR
-T' 15- IN PUMPED SYSTEM
is
o�o
T p 00 HIGH 000 0
30" 2'¢" 0$pp POLYETHYTMLENE 00 0 0
EFFEC. coo O tNFiLTRATOR 3050 O 00 O
DEPTH00 CHAMBER 00
GRD EL ��
ADJ GW EL 2 9
REI ORCED Cad TEES TO BE CENTERED UNDER MANHOLE COVER.
2. SEPTIC. TANK TO WfTHSTAND H-20 LOADING
47" 50" 47"
R41SHED GR
jr tt
"
2 WALLS NOTES:
A GARBAGE GANDER JS NOT
//I
RECOMMENDED" DUE TO RECOGNIZED
"
3. ALL PIPE CONNECTIONS AND CONCRETE
SHALL BE
ADVERSE IMPACTS TO THE LEACHING
is•o..+n:
2'
1. DISI BOX TO WITHSTAND H-20 LOADING
FLAG %
01F r
%
/ //
TheBSC Cx ,Inc. Y
�T}
$
LOAM SAVOY 10YR 5/8
CONSTRUCTION WATERTIGHT.
4 FILL ALL UNUSED KNOCKOUTS WITH
WEST YARMOUTH, ,MA 02673
,:•o.:•
T
PROJECT TITLE:
PV0BARRIER
2. PROVIDE INLETTEEOR BAFFLE WHERE
MORTAR.SLOPE OF PIPE: EXCEEDS 0.08 FT./FT OR
-T' 15- IN PUMPED SYSTEM
is
EL ' 11.0T 2-24" DIA C.I. (60p MIN, MANHOLE COVERS w
3' TEE TO BE UNDER BROUGHT TO FINISH GRADE 6 5,5" OUTLETS 8 l 3. FIRST TWO FEET OF PIPE OUT OF DIST. 35
° + " SAND 25YR 6/6 M.H. OPENING t " MIN. "o " a T BOX TO BE LAID LEVEL PLAN VIEW - LEACHING CHAMBERS
q 4 C1 4$ 6" 'm L.- 2" 4. ALL PIPE CONNECTIONS AND CONCRETE
CONSTRUCTION SHALL BE' WATERTK;}!T. LOAM & SEED DISTURBED AREAS
Q•
,p 5' 60" RAISE M.H W 6" BOTTOM ON LEVEL
11'-O" 6" MIN. 3//4" TO
SEWER BRICK a . -o- •:. :a STABLE BASE 1 1/2' CRUSHED
S. FILL ALL UNUSED KNOCKOUTS WITH MORTAR,
1 6' IV D 1 &MORTAR i2 CROSS-SECTION STONE BASE 3' MAX. COMPACTED FILL 36" MAXIMUM 12"MINIM M
■U.
NORMAL WATER.LEVEL
3" 00 00000 000 000 000 0
st INDICATES
c 8• C2 -v OBSERVED' PRECAST SEPTIC TANK 1D" 2D'
7T
SAND 2sYR !i/3 - GROUND WATER �� TEE 6 -4
6'-1" L -'5v. -4w MIN. �70' EL = 2.9' - INDICATESUID DEPTH �)�.ESTIMATED
SEASONAL HIGH _WET. SAND - NO STANDING GROUND WATER:'•' .
CFO
o�o
T p 00 HIGH 000 0
30" 2'¢" 0$pp POLYETHYTMLENE 00 0 0
EFFEC. coo O tNFiLTRATOR 3050 O 00 O
DEPTH00 CHAMBER 00
:
47" 50" 47"
4" PVC: (PERF)
A GARBAGE GANDER JS NOT
//I
RECOMMENDED" DUE TO RECOGNIZED
4" PVC
PIPE
ADVERSE IMPACTS TO THE LEACHING
4• PVC
LEACHING CHAIVBER
EL ' 11.0T 2-24" DIA C.I. (60p MIN, MANHOLE COVERS w
3' TEE TO BE UNDER BROUGHT TO FINISH GRADE 6 5,5" OUTLETS 8 l 3. FIRST TWO FEET OF PIPE OUT OF DIST. 35
° + " SAND 25YR 6/6 M.H. OPENING t " MIN. "o " a T BOX TO BE LAID LEVEL PLAN VIEW - LEACHING CHAMBERS
q 4 C1 4$ 6" 'm L.- 2" 4. ALL PIPE CONNECTIONS AND CONCRETE
CONSTRUCTION SHALL BE' WATERTK;}!T. LOAM & SEED DISTURBED AREAS
Q•
,p 5' 60" RAISE M.H W 6" BOTTOM ON LEVEL
11'-O" 6" MIN. 3//4" TO
SEWER BRICK a . -o- •:. :a STABLE BASE 1 1/2' CRUSHED
S. FILL ALL UNUSED KNOCKOUTS WITH MORTAR,
1 6' IV D 1 &MORTAR i2 CROSS-SECTION STONE BASE 3' MAX. COMPACTED FILL 36" MAXIMUM 12"MINIM M
■U.
NORMAL WATER.LEVEL
3" 00 00000 000 000 000 0
st INDICATES
c 8• C2 -v OBSERVED' PRECAST SEPTIC TANK 1D" 2D'
7T
SAND 2sYR !i/3 - GROUND WATER �� TEE 6 -4
6'-1" L -'5v. -4w MIN. �70' EL = 2.9' - INDICATESUID DEPTH �)�.ESTIMATED
SEASONAL HIGH _WET. SAND - NO STANDING GROUND WATER:'•' .
CFO
y EL = 0.9 144 WATER OR WEEPING VISIBLE . 12
12 BOTTOM ON LEVEL STABLE BASE
, TIDAL INFLUENCE � �2 • .
DATE:
PLAN .VIEW �i•2C.Y.! �I'�1►.aC.` 7 t/
-INDICATES
N ICCA• ES 6 MIN. 3 S To CROSS-SECTION VIEW PLAN VIEW CROSS-SECTION OF CHAMBER
8/10/2000 t t/2" SrONE
ITHE BSC GROUP, INC. TEST BY.
TEST
3" LAYER
3/4" -I 1 2"
WASHED ST E
'. CHAR OTTE STTEFEL (BARN. CO. DESIGN CRITERIA:
I , . INDICATES
PERC. RATE: � UNSUITABLE DESIGN FLOW:
L - 2 MIN./INCH MATERIAL
4 BEDROOMS AT110G.P.B./D 440 G.P.D.
Y SOIL EVALUATOR
r, CRAIG A. FIELD. ---------------=----
I ---C------ -� W -7
SOIL CLASS: BENCHMARK / - - - - - - \ /
k f CENTER OF CATCHBASIN
' 1 PLEASANT ^ STREET REQUIRED sEPrlc TANK:
ELEVATION. 13.57 d 440 X 200%_
880 GAL.
,.
L.T.A.R. --- / i� b t\\STREET
TANK PROVIDED: = 2000 AL.
9.74 G.P.D./SQ.FT.---/------/---\ EDGE OF PAVEMENT
\ !l
DATUMhv41.32'30"E 110.00'I/ SIZE .OF LEACHING FACILITY REQUIRED:
VERTICAL DATUM: ;'N.G.V.D. CB/DH \
140.97' DESIGN PERC. RATE: <2 MIN./ INCH
BENCH MARK USED. RM -13 HYDRANT 27.42 y 3
BENCH> MARK SET:; CENTER OF CATCH BASIN 13.57' ¢ LONG TERM APPL. RATE 0.74 G.P.D/S.F.
I� PROPOSED
PROFILE: NOT,TO SCALE RESERVE
/
EL- A SIZE OF LEACHING FACILITY PROVIDED:
FIRST PIPE LENGTH
TOP FOUNDATION 13.3
CONCRETE COVERS TO WITHIN TO BE SET'LEVEL m X /
r
EE =14.2 6' OF FINISHED GRADE. FOR MIN. ?` > FLAG POLE / 1 //
x s FlNISH.GRADETO 8E RELOCATED I /// 440 GPD + 0.74 SF/GPD 595 S.F.
2• MIN / /
r _
o�o
T p 00 HIGH 000 0
30" 2'¢" 0$pp POLYETHYTMLENE 00 0 0
EFFEC. coo O tNFiLTRATOR 3050 O 00 O
DEPTH00 CHAMBER 00
:
47" 50" 47"
4" PVC: (PERF)
y EL = 0.9 144 WATER OR WEEPING VISIBLE . 12
12 BOTTOM ON LEVEL STABLE BASE
, TIDAL INFLUENCE � �2 • .
DATE:
PLAN .VIEW �i•2C.Y.! �I'�1►.aC.` 7 t/
-INDICATES
N ICCA• ES 6 MIN. 3 S To CROSS-SECTION VIEW PLAN VIEW CROSS-SECTION OF CHAMBER
8/10/2000 t t/2" SrONE
ITHE BSC GROUP, INC. TEST BY.
TEST
3" LAYER
3/4" -I 1 2"
WASHED ST E
'. CHAR OTTE STTEFEL (BARN. CO. DESIGN CRITERIA:
I , . INDICATES
PERC. RATE: � UNSUITABLE DESIGN FLOW:
L - 2 MIN./INCH MATERIAL
4 BEDROOMS AT110G.P.B./D 440 G.P.D.
Y SOIL EVALUATOR
r, CRAIG A. FIELD. ---------------=----
I ---C------ -� W -7
SOIL CLASS: BENCHMARK / - - - - - - \ /
k f CENTER OF CATCHBASIN
' 1 PLEASANT ^ STREET REQUIRED sEPrlc TANK:
ELEVATION. 13.57 d 440 X 200%_
880 GAL.
,.
L.T.A.R. --- / i� b t\\STREET
TANK PROVIDED: = 2000 AL.
9.74 G.P.D./SQ.FT.---/------/---\ EDGE OF PAVEMENT
\ !l
DATUMhv41.32'30"E 110.00'I/ SIZE .OF LEACHING FACILITY REQUIRED:
VERTICAL DATUM: ;'N.G.V.D. CB/DH \
140.97' DESIGN PERC. RATE: <2 MIN./ INCH
BENCH MARK USED. RM -13 HYDRANT 27.42 y 3
BENCH> MARK SET:; CENTER OF CATCH BASIN 13.57' ¢ LONG TERM APPL. RATE 0.74 G.P.D/S.F.
I� PROPOSED
PROFILE: NOT,TO SCALE RESERVE
/
EL- A SIZE OF LEACHING FACILITY PROVIDED:
FIRST PIPE LENGTH
TOP FOUNDATION 13.3
CONCRETE COVERS TO WITHIN TO BE SET'LEVEL m X /
r
EE =14.2 6' OF FINISHED GRADE. FOR MIN. ?` > FLAG POLE / 1 //
x s FlNISH.GRADETO 8E RELOCATED I /// 440 GPD + 0.74 SF/GPD 595 S.F.
2• MIN / /
r _
m
:
SHED
4" PVC: (PERF)
A GARBAGE GANDER JS NOT
//I
RECOMMENDED" DUE TO RECOGNIZED
✓ = °
y ,.4
ADVERSE IMPACTS TO THE LEACHING
4• PVC
LEACHING CHAIVBER
M/0
LOT 1-B "
FLAG %
01F r
%
/ //
TheBSC Cx ,Inc. Y
USE HI LEACHING CHA
.,
WEST YARMOUTH, ,MA 02673
(508) 778-8919
PROJECT TITLE:
SEWAGE DISPOSAL
SYSTEM DESIGN
#118.`
PLEASANT STREET
co
MASSACHUSETTS
STDEWALL = 2112'+35'
RICHARD & DEBRA MARTIN
118 PLEASANT STREET
BASS RIVER, MA 02664
1=G
COMP. DESIGN: K. HEALY
L
DRAWN: P. HAGIST
ADJUSTED .GROUNDWATER
2.9 J
FILE NO. 8210-SEP.DWG
BLITTOM _ 12' X '35
JOB NO. 4-8210.00
1=E s'
LOCUS PLAN: NO SCALE
H
FOR TIDAL
/ 13.6
�Y �c�
. -
I=F
DISOT.
o i2"
�� X
i
608 S.F x 0,74 SF/GF
•.
2000 BALLON
Box
5' SEPERA710N
N OAK
//
� _ /
%
_
(�
`
SEPTIC TANK
kms. .y ,..
NO OBSERVED GROUNDWATER
PROPOSED
12'x35' S.A.S. N.
/ / 1A'' \\
/
\1,,-
<
6` STONE BASE
J 80TTOM OF'TEST HOE
/C jt
I r�
/ \
1
,�.�/ i
o
PROPOSED LOCUS INFORMATION
x INVERT ELEVATIONS: ADDITION,fl / o GAL
p /2.000 ( I �a
EXISTING , ,{ S I
TOP OF FOUNDATION 15.'15' A E GAS UNE 11'3l' $� �/o� / TANj� I / CURRENT OWNER: KYLE NOMINEE TRUST
TO B 1 A I
.:_ 4" INVERT AT BUILDING 11.50'. B RELOCATED �/ r 1/ yc TITLE REFERENCE: DEED BOOK 11119-289
4" INVERT AT SEPTIC TANK IN 11.25' C /
" ( } EXISTING' �CIS1iNG 'fr oQ PLAN REFERENCE: PLAN BOOK 106, PAGE 23
4 INVERT AT SEPTIC TANK (OUT} 11.00 D .: GiA�'EIA'� m
GAS METER �6a B ry
_ 4" INVERT AT DIST. BOX (IN) 10.17' Ems' ASSESSORS MAP: 51
4" INVERT AT DIST. BOX (OUT} 10,00'FYI c PARCEL: 76
RESIDENTIAL ZONE: RS -40
INV=12.7 op SETBACKS: FRONT 30'
EXISTING PLUMBING C1tA10A �v
SIDE 20' INVERTS AT LEACHING FACILITY: INSIDE HOUSE TO BE . °yip D REAR 20'
L ` PAD / 4 -BEDROOM REPLUMBED AS SHOWN'.
cn
co 4" INVERT AT BEGINNING �� i CWELLING �Q MINIMUM.LOT SIZE: 40:000 S.F.
OFA-EACHING,CHAMBER 9.9' G ,� '�• ,j #118
rNv GROUNDWATER
`a
EE ATION AT BOTTOM : h OVERLAY DISTRICT: NOT A ZONE It
Ysx , m VARIANCES REQUESTED: s,o 28
x a z N
l?- N
LOCUS .
LOT 1-C
PLAN VIEW
299445± S.F.CL
�\\ SCALE: 1" = 20 FEET
0
N
0 10 20 40 FT.
o I
SHIP' IIP S H 0!-A S41 32'30"W (PRIVATE) 110.00, CB/DH
Y LOT 1-D
REVISIONS
NO. DATE DESCRIPTION
GENERAL NOTES:
1. THIS PLAN IS FOR DESIGN AND
CONSTRUCTION OF THE SEWAGE
DISPOSAL FAgUTY ONLY:
2. ALL CONSTRUCTION METHODS AND
MATERIALS MALL CONFORM TO MASS.
D.E.P TITLE 5 AND LOCAL BOARD
OF HEALTH REGULATIONS.
3. ALL PIPES LOCATED UNDER PAVEMENT
OR TRAVELED WAY SHALL BE SCHEDULE
40 OR EQUAL
4. THERE ARE NO KNOWN PRIVATE WELLS
LOCATED WITHIN 150 FT. OF THE
PROPOSED LEACHING FACILITY NOR
ANY KNOWN WELLS PROPOSED WITHIN
15W OF ANY KNOWN LEACHING FACIUTY.
5. WITHIN LIMIT OF EXCAVATIONREMOVE
ALL TOPSOIL. SUBSOIL AND OTHER
IMPERVIOUS MATERIAL
6. REPLACE WITH CLEAN WASHED SAND
OR OTHER CLEAN GRANULAR SOILS
CONFORMING TO THE FOLLOWING
SIEVE ANALYSIS:
10% (MAX) BY WE SHALL
PASS No. 50 SIEVE
<10 % OF No. 4 SIEVE SHALL
PASS No. 100
<5 X OF No. 4 SIEVE SHALL
PASS No. 200
UNIFORMITY COEFFICIENT O No. 4
SIEVE </-6.0
7. EXISTING UTILITIES WHERE SHOWN
IN THE DRAWINGS ARE APPROXIMATE,
THE CONTRACTOR 'SHALL BE RESPON-
SIBLE FOR PROPERLY LOCATING AND
COORDINATING THE PROPOSED CON-
STRUCMON ACTIVITY WITH DIG -SAFE
AND THE APPLICABLE UTILITY
COMPANY AND MAINTAINING THE
EXISTING UTILITY SYSTEM IN SERVICE:.
DIG -SAFE SHALL BE NOTIFIED PER
THE STATE OF MASSACHUSETTS
STATUTE CHAPTER 82, SECTION 409
AT TEL 1-888-344-7233 THE
ENGINEER DOES NOT GUARANTEE'
THEIR ACCURACY OR CHAT ALL
UTILITIES AND SUBSURFACE STRUCTURES
ARE SHOWN. LOCATIONS AND
ELEVATIONS OF UNDERGROUND UTILITIES'
TAKEN FROM RECON PLANS. THE
CONTRACTOR SHALL VERIFY SIZE,
LOCATION AND INVERTS OF UTILITIES
AND STRUCTURES AS REQUIRED PRIOR
TO THE START OF CONSTRUCTION.
8
m
L V
EACHINCHAMBER 79,H
SHED
-7
A GARBAGE GANDER JS NOT
00
RECOMMENDED" DUE TO RECOGNIZED
ADVERSE IMPACTS TO THE LEACHING
DfCK
TheBSC Cx ,Inc. Y
657 ROUTE _28r (UNIT IS),'.
WEST YARMOUTH, ,MA 02673
(508) 778-8919
PROJECT TITLE:
SEWAGE DISPOSAL
SYSTEM DESIGN
#118.`
PLEASANT STREET
co
MASSACHUSETTS
PREPARED FOR:
RICHARD & DEBRA MARTIN
118 PLEASANT STREET
BASS RIVER, MA 02664
DATE: 9/11/00
COMP. DESIGN: K. HEALY
L
DRAWN: P. HAGIST
ADJUSTED .GROUNDWATER
2.9 J
FILE NO. 8210-SEP.DWG
POOL
SHEET t of 1
JOB NO. 4-8210.00
LOCUS PLAN: NO SCALE
FOR TIDAL
, �/
1
•.
No. 32112
I, .....
`
.P
kms. .y ,..
Ysx , m VARIANCES REQUESTED: s,o 28
x a z N
l?- N
LOCUS .
LOT 1-C
PLAN VIEW
299445± S.F.CL
�\\ SCALE: 1" = 20 FEET
0
N
0 10 20 40 FT.
o I
SHIP' IIP S H 0!-A S41 32'30"W (PRIVATE) 110.00, CB/DH
Y LOT 1-D
REVISIONS
NO. DATE DESCRIPTION
GENERAL NOTES:
1. THIS PLAN IS FOR DESIGN AND
CONSTRUCTION OF THE SEWAGE
DISPOSAL FAgUTY ONLY:
2. ALL CONSTRUCTION METHODS AND
MATERIALS MALL CONFORM TO MASS.
D.E.P TITLE 5 AND LOCAL BOARD
OF HEALTH REGULATIONS.
3. ALL PIPES LOCATED UNDER PAVEMENT
OR TRAVELED WAY SHALL BE SCHEDULE
40 OR EQUAL
4. THERE ARE NO KNOWN PRIVATE WELLS
LOCATED WITHIN 150 FT. OF THE
PROPOSED LEACHING FACILITY NOR
ANY KNOWN WELLS PROPOSED WITHIN
15W OF ANY KNOWN LEACHING FACIUTY.
5. WITHIN LIMIT OF EXCAVATIONREMOVE
ALL TOPSOIL. SUBSOIL AND OTHER
IMPERVIOUS MATERIAL
6. REPLACE WITH CLEAN WASHED SAND
OR OTHER CLEAN GRANULAR SOILS
CONFORMING TO THE FOLLOWING
SIEVE ANALYSIS:
10% (MAX) BY WE SHALL
PASS No. 50 SIEVE
<10 % OF No. 4 SIEVE SHALL
PASS No. 100
<5 X OF No. 4 SIEVE SHALL
PASS No. 200
UNIFORMITY COEFFICIENT O No. 4
SIEVE </-6.0
7. EXISTING UTILITIES WHERE SHOWN
IN THE DRAWINGS ARE APPROXIMATE,
THE CONTRACTOR 'SHALL BE RESPON-
SIBLE FOR PROPERLY LOCATING AND
COORDINATING THE PROPOSED CON-
STRUCMON ACTIVITY WITH DIG -SAFE
AND THE APPLICABLE UTILITY
COMPANY AND MAINTAINING THE
EXISTING UTILITY SYSTEM IN SERVICE:.
DIG -SAFE SHALL BE NOTIFIED PER
THE STATE OF MASSACHUSETTS
STATUTE CHAPTER 82, SECTION 409
AT TEL 1-888-344-7233 THE
ENGINEER DOES NOT GUARANTEE'
THEIR ACCURACY OR CHAT ALL
UTILITIES AND SUBSURFACE STRUCTURES
ARE SHOWN. LOCATIONS AND
ELEVATIONS OF UNDERGROUND UTILITIES'
TAKEN FROM RECON PLANS. THE
CONTRACTOR SHALL VERIFY SIZE,
LOCATION AND INVERTS OF UTILITIES
AND STRUCTURES AS REQUIRED PRIOR
TO THE START OF CONSTRUCTION.
8
THIS =SYSTEM IS NOT DESIGNED FOR
THE USE OF A 'GARBAGE GRINDER..
A GARBAGE GANDER JS NOT
RECOMMENDED" DUE TO RECOGNIZED
ADVERSE IMPACTS TO THE LEACHING
FACiUTY.
TheBSC Cx ,Inc. Y
657 ROUTE _28r (UNIT IS),'.
WEST YARMOUTH, ,MA 02673
(508) 778-8919
PROJECT TITLE:
SEWAGE DISPOSAL
SYSTEM DESIGN
#118.`
PLEASANT STREET
SO. YARMOUTH
MASSACHUSETTS
PREPARED FOR:
RICHARD & DEBRA MARTIN
118 PLEASANT STREET
BASS RIVER, MA 02664
DATE: 9/11/00
COMP. DESIGN: K. HEALY
CHECK: D. CRISPIN
DRAWN: P. HAGIST
FIELD: D. GAZZOLO / D. BROWN
FILE NO. 8210-SEP.DWG
DWG NO. 5239-01
SHEET t of 1
JOB NO. 4-8210.00