Loading...
HomeMy WebLinkAbout40 Pleasant Street Site Plan 5EXIST. TOP FNDN @ 12.8' SYSTEM PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO 12.3' MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE -- 1 D D, RUN PIPE LEVEL /FOR FIRST 2' PROPOSED 1500 1 GALLON SEPTIC 9.55' 9'8 TANK (H- 10 ) GAS BAFFIN 9.30' (-2-7 SLOPE) \__6" CRUSHED STONE OR MECHANICAL DEPTH OF FLOW 4 COMPACTION. (15.221 [2]) (-L-% SLOPE) ( i SLOPE) ' THIS IS A TEE SIZES: PROPOSED INVERT INLET DEPTH = 1O" OUT OF FNDN. OUTLET DEPTH = 14 PROVIDE PROPER SOIL COVER OVER PIPING FOUNDATION- 10' SEPTIC TANK - Q_v1� HIGH PT. CJ`S / BENCHMARK - CENTER OF 15.0 DRAIN. MANHOLE COVER �a.7 ELEV. = 14.70 (NGVD) pf , y1P' 14. 5�/ i/ la , 3.6 i s / .rte, � � q�! 00 G / ' � pg 14�7f 9 �� �4.0 ry EXIST. p \ / EVERG5ENS� :XISTING GASUNE tE-ROUTE AS NECESSAR' USE CAUTION IN AREA OF GASLINE �\ < \ 25' SLOPE REQUIRED OVER SYSTEM 12.3' 5.09' D' BOX 8' LEACHING FACILITY ADJ. WATER @ 3.4' -I- LOCATION OF EXISTING SEPTIC SYSTEM UNKNOWN 12.6 \ \\13.3 \ EXISTING FIRE DAMAGED DWEWNG 1� \ \ TOP FNDN a 128' (TO BE REBUILT) ERIC 2. \ WALK 13.3 \�73 a " G•E` i - OF' + 6/9 FLOODZONE EL. 9.0' � , `yam 1 PtR cA. (T GAR. � 4.0r/ N8. 7.3 EXIST. BE WED) 7 / `L GAR. / 7.2 '9 All TEST HOLE LOGS ENGINEER: M.S. FARIA, SE WITNESS: KELDA GORMAN DATE: MAY 3, 2000 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# Q ELEV. 0" 12.6' 0„ 0/A SL 12" 10YR 4/2 B LS 30" 10YR 5/8 10.1' Cl M -F SAND 90" 2.5Y 6/6 C2 FS 2.5Y 7/2 odj. water 3.4' 126" obs. water 2.1' 132" 1.6' S.--PTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: _5_ BEDROOMS (110 GPD) = 550 GPD USE A 550 GPD DESIGN FLOW SEPTIC TANK: 550 GPD ( 2 ) = 1100 USE A 1500 GALLON SEPTIC TANK LEACHING: SIDES: N/A BOTTOM: 22.5 x 33.25 (.74) = 553.6 TOTAL: 748 S.F. 553.6 GPD USE (15) STANDARD H-20 INFILTRATORS WITH 3' OF^STONE AT SIDES, 4' BETWEEN ROWS AND 1' AT LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR - - 100- - EXISTING CONTOUR BOARD OF HEALTH 4 LOCATION MAP 4 -- NOT TO SCALE ASSESSORS MAP 61 PARCEL 97 ZONING DISTRICT: RS 40 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF. - 45/101 FLOOD ZONE: A8 EL. 9, B AND C 250015 0004C 6/17/86 ELEVATIONS NGVD WELL: MIW 29 ZONE: A ADJ: 1.3' NOTES: 1. DATUM IS iNvVu 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9, COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. PUMP & REMOVE (OR FILL W/CLEAN SAND) EXIST. SEPTIC SYSTEM. TITLE 5 SITE PLAN OF 40 PLEASANT STREET IN THE TOWN OF: (SOUTH) YARMOUTH PREPARED FOR: BRUCE DANIEL 30 0 30 .• •# 64C/#65C // / DATE MA SCALE 1' = 30' DATE: JUNE 5, 2000 APPROVED REV. 7/17/00 (MOVE SAS) REV. 8/22/00 (HSE) off 508-362-4541 REV. 8/28/00 m. soa 362-e880 (SAS, HSE) \ i) \97 �aBJ I V\N 0f M REV. 4/18/01 (gar) qJ 4.3 1t) rp, r _.} 5 ���' AS.Cp�, ���lH OF �.�,� / down Cape engineering, inc. �o ARNE H.-^ H. #1 f.OGE S9� f� �, 3 y�L / . I\ \ R, c�i CML w j OJALA � E yaR� 11 / N X33 ��� CIVIL ENGINEERS No. 30792 `; No.2s318 `� 4�y3 / Ck A- T -AND SURVEYORS ��7rEgfCfSTERi���44Q ��s CI •f F rCj sSIDNAI E116•YA! kc 70-112 " �P 939 main st. Yarmouth, ma 02675 ARNE K WALA, P.E., P.L.S PROP. � 14 \ �y GAR. 4. Gly .4 13\\ Q, IV \ 13 1 PARCEL 97 1 \\7 8.650± SF UPLAND 2012± SF WETLAND ;20,662± SF TOTAL) 72, 3. :XISTING GASUNE tE-ROUTE AS NECESSAR' USE CAUTION IN AREA OF GASLINE �\ < \ 25' SLOPE REQUIRED OVER SYSTEM 12.3' 5.09' D' BOX 8' LEACHING FACILITY ADJ. WATER @ 3.4' -I- LOCATION OF EXISTING SEPTIC SYSTEM UNKNOWN 12.6 \ \\13.3 \ EXISTING FIRE DAMAGED DWEWNG 1� \ \ TOP FNDN a 128' (TO BE REBUILT) ERIC 2. \ WALK 13.3 \�73 a " G•E` i - OF' + 6/9 FLOODZONE EL. 9.0' � , `yam 1 PtR cA. (T GAR. � 4.0r/ N8. 7.3 EXIST. BE WED) 7 / `L GAR. / 7.2 '9 All TEST HOLE LOGS ENGINEER: M.S. FARIA, SE WITNESS: KELDA GORMAN DATE: MAY 3, 2000 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# Q ELEV. 0" 12.6' 0„ 0/A SL 12" 10YR 4/2 B LS 30" 10YR 5/8 10.1' Cl M -F SAND 90" 2.5Y 6/6 C2 FS 2.5Y 7/2 odj. water 3.4' 126" obs. water 2.1' 132" 1.6' S.--PTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: _5_ BEDROOMS (110 GPD) = 550 GPD USE A 550 GPD DESIGN FLOW SEPTIC TANK: 550 GPD ( 2 ) = 1100 USE A 1500 GALLON SEPTIC TANK LEACHING: SIDES: N/A BOTTOM: 22.5 x 33.25 (.74) = 553.6 TOTAL: 748 S.F. 553.6 GPD USE (15) STANDARD H-20 INFILTRATORS WITH 3' OF^STONE AT SIDES, 4' BETWEEN ROWS AND 1' AT LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR - - 100- - EXISTING CONTOUR BOARD OF HEALTH 4 LOCATION MAP 4 -- NOT TO SCALE ASSESSORS MAP 61 PARCEL 97 ZONING DISTRICT: RS 40 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF. - 45/101 FLOOD ZONE: A8 EL. 9, B AND C 250015 0004C 6/17/86 ELEVATIONS NGVD WELL: MIW 29 ZONE: A ADJ: 1.3' NOTES: 1. DATUM IS iNvVu 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9, COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. PUMP & REMOVE (OR FILL W/CLEAN SAND) EXIST. SEPTIC SYSTEM. TITLE 5 SITE PLAN OF 40 PLEASANT STREET IN THE TOWN OF: (SOUTH) YARMOUTH PREPARED FOR: BRUCE DANIEL 30 0 30 .• •# 64C/#65C // / DATE MA SCALE 1' = 30' DATE: JUNE 5, 2000 APPROVED REV. 7/17/00 (MOVE SAS) REV. 8/22/00 (HSE) off 508-362-4541 REV. 8/28/00 m. soa 362-e880 (SAS, HSE) \ i) \97 �aBJ I V\N 0f M REV. 4/18/01 (gar) qJ 4.3 1t) rp, r _.} 5 ���' AS.Cp�, ���lH OF �.�,� / down Cape engineering, inc. �o ARNE H.-^ H. #1 f.OGE S9� f� �, 3 y�L / . I\ \ R, c�i CML w j OJALA � E yaR� 11 / N X33 ��� CIVIL ENGINEERS No. 30792 `; No.2s318 `� 4�y3 / Ck A- T -AND SURVEYORS ��7rEgfCfSTERi���44Q ��s CI •f F rCj sSIDNAI E116•YA! kc 70-112 " �P 939 main st. Yarmouth, ma 02675 ARNE K WALA, P.E., P.L.S