Loading...
HomeMy WebLinkAbout43 Pollock Rip Road - Site & Sewage Plan 2Of yrsS• N ASSESSORS MAP. ' 98 YY PARCEL' 40.41 & A PORTION OF 42 TEST ,HOLE LOGS NOTES: F 1., VERTICAL DATUM. ASSUMED FROM QUAD (NGVD +�-) LOCUS CURRENT ZONING: B-40EN :!NEER:- _ THOMAS McLELLAN, P.E. 2. MUNICAPAL HATER IS AVAILAB,4E. a BUILDING SETBACKS: !WITNESS: AMY VON HONES s, SCIiEDiI1.E ,f0 - 4' PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. P. 30' S: �0 R 20' DA7'E: 4 ALL' PRECAST UNITS TO CONFORM WITH AASiHTO •H-10 & H-20 04 PERCOLATION. RATE. < 2 MINIIN LOADING SPECIFICATIONS, 10-29-98 FLOOD ZONE: C ' 5. PIPE PITCiI = Y14' PER FOOT, (UNLESS NOTED OTHERWISE). TH-2 9� 6. FIRST 2. OF PIPE OUT OF D—BOX TO BE SET LEVEL.• aLjrv. xxiv. 7, TOE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE o 0/ Ir aNwnzox L/t/a�BaOxJ��oN USE SOF A GARBAGE' DISPOSAL fOYR Y/f 3&4 e' f01'�RYYi/1 sas 8. ALL CONSTRUCTION; DETAILS ARE TO BE IN ,CONFORMANCE WITH THE e HORtsroN B HORIZON SPATE OF MASS, ENVIRONMENTAL CODE TITLE, FIVE) AND LOCAL LOCATION MAP 30' YOYA n LOT 244 97A so- /OBD 33.5 HEALTH REGULATIONS. - 41,917 ± S.F. ��—•�vr�. JOHN Z c QE{AARFST Jfi � + C HORI7'ON a No. 36859 1 Cl HORIZON 0FF6S,� y�SUA 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR (0.96 ''V" THOMAS McLELLAN. P.E. f�qj,1D s� Wp 7% TO CONSTRUCTION. BENCHMARK AT MARKBWND. U?7= foe' 27.0Baxca 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO CONC. EXCEED W. KEY: ZLZV.-42.e Cl HORIZON EXISTING CONTOUR — — -- 41' 6 144' 27s 13r1 l2� 7%a n 246 PROPOSED CONTOUR : .............................. 4t 4 EXISTING SPOT ELEVATION. 25.5 _ _ 42 USCS GRWNDWATER ADJUSTMENT: PROPOSED SPOT ELEVATION: z5 TEST HOLE: �� 4t • 2 r WaL1: A1W-230, ZONE: C. ADJUSTMENT: 2D 4 UTILITY POLE: -0- FENCE LINE: r19 HYDRANT: 4a 7 .� ,�, : SEPTIC SYSTEM .DESIGN RETAINING SPALL: �. �G r .' �\ r4. TREE: �y �$ \ c+ FLOW ESTIMATE: 40 60� 4 ,2. BEDROOMS AT 110 GAL/DAY/BEDROOx -MCAL/DAY 5 SEPTIC TANK. 40.2 •\\D O'� \ �� \ .Ua- GAL/DAY x 2 DAYS = _ffQ GAL EXISTING USE 1500 GALLON SEPTIC TANK CATCH BASIN / ` \ \ \ ,LEACHING AREA: \ \ USE 3 CULTEC CHAMBERS (RECHARGER 3302 0 �/ •- �.� a' \ WITH 4' OF STONE ALL AROUND (28' x 12' z Z DEEP) /' — ' y¢p �9 ;z9 \ �\ ?it \\ \\ \\ SIDE AREA (28 +12)2 x 2 - 160 SF(.74) 118 GAL/DAY r �4 j ?� \ �\ �\ \ BOTTOM AREA 28' x 12' — 336 SF (.74} = 248 CAL,/DAY ' oe ' r o9 •' ` 9�•,. :' . ` `;. \ \ . - � _ __T. _. ___ _ _ CAPACITY - 367 GA4/DAY, UTILITY r _ SEPTIC SYSTEM SECTION , r r r TH-z \ \ \ 40 •89 41 40 Sg r r .• � r r S6 59 ' 58 r 1 , S6 r i DaMARaST-MQLELLAN ENGINEERING 24 SCHOOL STRaaT P.O. BOX 463 DM 98-180 (D3fF6) WAST DaNNIS. xASSACHUSN"S 02670 PHONE d FAX :(508) 39e-7710 2' PEASTONE COVERS WITHIN 12' OF 42D - WINISNZD GRAD! ((Oxl INSPECTION COVER TOP OF FOUNDATION tro BE WITHIN a of GRADS) HASHED STONE ELEV.- 37.5 37.75 ELEV. '. 38.0 1500 GAL D—BOX 37.08 0 ELEV. SEPTIC TANK 3'25 (6" OF ELEV. ELEV. 38S (6" OF STONE UNDER OR ELEV. STONE E ELEV. MECHANICALLY COMPACTED) UNDER) 3 CULTEC CHAMBERS (RECHARGER 330) TEE SIZES: 37'0 WITH 4' OF STONE ALL AROUND GIS BAFFLE INLET: 6' UP, 13" DOWN AT OUTLiT TEE ELEV. (28' x 12' x 2' DEEP) (H-20) OUTLET: 6' UP, 14' DOWN 5J' ADJUSTED GROUNDWATER ZL 7ATION - 29.9 APPROVED BY: DATE: �l"LfN•� ��—•�vr�. JOHN Z c QE{AARFST Jfi � + ftaw co a No. 36859 1 0FF6S,� y�SUA irA F,;i, ''V" THOMAS McLELLAN. P.E. JOHN Z. DEMAREST JR., P.L.S.