Loading...
HomeMy WebLinkAbout36 Pompano Road - Site & Sewage Plan 2N ASSESSORS MAP: 112 q LOCUS PARCEL: J 31 8 eA g0� CURRENT ZONING: R-40 BUILDING SETBACKS: F: 30' S: 6' R: 20' FLOOD ZONE: C MILL POND LOCATION MAP 1 A0 E O1 �007- 31 17,413 f S.F. 48� / / l (0.40 ± AC.) / 48 48. 2� / 49! - _ _-47 �a ` _ - _ - - - - - - - - - 48 -49 49. - _ _ -50 r — — 51 51 54- TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. N DATE: 6-23-98 PERCOLATION RATE: < 2 MIN /IN TH-1 TH-2 56D ELEV.. 0/A HORIZON 0/A HORIZON LOAMY SAND LOAMi' SAND 7' loYR 4/3 55.4 r 10rR 4/3 B HORIZON B HORIZON SANDY LORI{ SANDY LOAM 30' fOYR 5/6 535 28" loYR 5%6 Cl HORIZON Cl HORIZON SANDrLOM �SAND 54" Z" 614 515 36" C2 HORIZON C2 HORIZON MEDIUM SAN MEDIUM4 SAND 4 2.5Y 55 — _ 52 — _ _ _ ♦ 53 56 ggsg \ \ 54 1 54 57 • SS Act1 1 1 53 � 1 2 1 QgUE9F�G660 50 49 48 57� 6T / / / / / / / 47 / 46 /45 55 - NO GROUNDWATER ENCOUNTERED NOTES: I. VERTICAL DATUM. • ASSUMED FROM QUAD (NGVD +/-) 2. MUNICAPAL WATER IS AVAILABLE. S. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-10 LOADING SPECIFICATIONS. 5. PIPE PITCH= 1/4" PER FOOT, (UNLESS NOTED OTHERWISE). 57.0 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL, EaEv. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. sm 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CdNFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL 54.7 HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 54.0 10. GROU4VD COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO ` EXCEED 3.0. 11. ALL UNSUITABLE SOIL (SANDY LOAM, APPROX. 54" DEEP) WITHIN 5. OF 47.0 PROPOSED LEACH AREA IS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. SEPTIC SYSTEM DESIGN FLOW ESTIMATE: -3- BEDROOMS AT 110 CAL/DAY/BEDROOM = 330 GAL/DAY SEPTIC TANK: 330 CAL/DAY x 2 DAYS = 660 CAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 3 INFILTRATORS (MAXIMIZER CHAMBERS) WI7H4'-DF STONE ALL AROUND (30'x 1T x 2' DEEP) SIDE AREA: _(30 + 11)2 x 2 = 164 SF (.74) - 121 CAL/DAY B(TTOM AREA: 30' x 11' = 330 SF (74) =_g44 GAL/DAY CAPACITY = 365 GAL/DAY SEPTIC SYSTEM SECTION 58.0 TOP OF FOUNDATION 54.0 ELEV. 11 t4 44 43 54 UTILITY i KEY: 53/ i / 44 EDGE OF PAVE EXISTING CONTOUR: — — — — / ' f� D PROPOSED CONTOUR: .............................. EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25 TEST HOLE: UTILITY POLE: -o- FENCE LINE: — HYDRANT: -6 RETAINING WALL: TREE: io DM # jR--WZ (D29F14) 49 t00000 BENCHMARK AT TOP OF "BAR ELEVr517 UTILITY s% 47 R,O A 2 POMPANO DEMAREST—MCLELLAN ENGINEERING 24 SCHOOL STREET P.O. BOX 463 WEST DENNIS, MASSACHUSETTS 02670 PHONE A' FAX : (508) 398-7710 53.8 1500 CAL ELEV. SEPTIC TANK (6" OF STONE UNDER OR MECHANICALLY COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN APPROVED BY: THC": 1131 Woo CIVIL COVERS WITHIN 1x of FINISHED CRADE ONE COVER TO BE WITHIN OF FINISHED GRADE) 53.55 L ELEV. D -BOX 53.2 53.37 -111(61r -OF ELEV. ELEV. STONE UNDER) GAS BAFFLE AT OUTLET TEE F -j-'G-c� DATE: THOMAS McLELLANTHOMAS McLELLAN, P.E. Z. DEMAREST JR, DEMAREST JR., ELEV PROPOSED 3 BEDROOM �, DWELLING pAT10 40' PROPOSED DWELLING 2" PEASTONE 3/4" - 1 1/2 - WASHED STONE ELEV.= 53.0 / FI ®FI ,f7 50.5 E4 E ELEV. E— 30' 3 INFILTRATORS (MAXIMIZER CHAMBERS) WITH 4' OF STONE ALL AROUND (30' x 1T x 2' DEEP) SITE AND SEWAGE PLAN LOCATION.' 36 POMPANO ROAD YARMOUTHPORT MA. PREPARED FOR' REEF REALTY SCALE: ��201 DATE. 7-6-98 REFERENCE: PLAN BOOK 207 PACE 57 REVISED: 7-13-98 15;�111DiAIZ-