HomeMy WebLinkAbout25 Railroad Avenue Structural Notes23. THE USE OF CONTROL JOINTS IN THE SLABS
WIDE TO A DEPTH OF 1/4 SLAB THICKNESS WITH
CLEAN AND PREPARE JOINTS AND FILL SOLID WIT
OR AN APPROVED EQUAL REINFORCING STEEL SH
24. CHAIR BARS FOR SECURE PLACEMENT AND P
BRICK, WOOD, OR OTHER NON -CONFORMING REIN
SUPPORT CHAIRS SHALL BE 18" IN EACH DIRECT]
a
v
0
N
O
R
i REQUIRED TO CONTROL CRACKING. SAW CUT CONTROL JOINTS 1/4-
48 HOURS OF CONCRETE PLACEMENT. AFTER CONCRETE HAS CURED,
'SIKADUR 51 SL.FLEXIBLE EPDXY CONTROL JOINT RESIN" (SIKA CORP.)
1 EXTEND CONTINUOUS THROUGHSLAB AT CONTROL JOINTS.
TIIONING OF REINFORCING STEEL IS TO BE PROVIDE IN NO CASE SHALL
IRCING STEEL SUPPORTS BE USED. MA'UMUM SPACING OF MESH
t ,1
WOOD FRAMING NOTES
1. ALL FRAMING LUMBER SHALL CONFORM TO THE LATEST EDITION OF THE NFPA "NATIONAL DESIGN SPECIFICATION FOR
WOOD CONSTRUCTION", AND SUPPLEMENT 'DESIGN VALUES FOR WOOD CONSTRUCTION', LATEST EDITION. MAXIMUM MOISTURE
CONTENT SHALL BE 19%.
2. ALL WOOD MEMBERS USED FOR PLACEMENT AGAINST CONCRETE OR MASONRY (SILLS, PLATES, ETC.) SHALL BE
PRESSURE TREATED WITH ACO PRESERVATIVE, OR APPROVED EQUAL, TO MINIMUM RETENTION OF 0.6 PCF IN ACCORDANCE
WITH AWPA C3.
3. THE FRAMING LUMBER SHALL BE OF THE FOLLOWING MINIMUM GRADE AND SPECIES FOR THE SPECIFIED USE. ALL
LUMBER SHALL BE GRADE STAMPED BY A RECOGVIZED GRADING AGENCY AND SHALL BE KILN DRY:
s PRESSURE TREATED: SOUTHERN PINE GRADE NO. 2, OR BETTER, WITH A MINIMUM ALLOWABLE BENDING STRESS (FB) -975
PSI AND MINIMUM MODULUS OF ELASTICITY (E)m1,600,000 PSI.
• NON PRESSURE TREATED:
4. DETAILS OF WOOD FRAMING SUCH AS NAILING, BLOCKING, BRIDGING, FIRESTOPPING, ETC. SHALL CONFORM TO THE
LATEST EDITION OF THE NATIONAL DESIGN SPECIFCATION (NFPA), THE TIMBER CONSTRUCTION MANUAL (ARC), AND
ARCHITECTURAL GRAPHICS STANDARD BY RAMSEY & SLEEPER.
5. ALL ENGINEERED LUMBER PRODUCTS SHALL B- AS MANUFACTURED BY THE TRUSS JOIST CORPORATION, BOISE CASCADE,
LOUISIANA PACIFIC CORPORATION OR APPROVED EQUALL
6. FOLLOW MANUFACTURERS' SPECIFICATIONS FOR ERECTION, INSTALLATION, AND PLACEMENT OF ENGINEERED LUMBER
PRODUCTS. PENETRATIONS THROUGH ENGINEERED LUMBER PRODUCTS IS EXPRESSLY NOT PERMITTED WITHOUT PRIOR
WRITTEN APPROVAL BY THE ENGINEER.
7. ALL LAMINATED VENEER LUMBER (LVL) TO HANE A MINIMUM ALLOWABLE BENDING STRESS (FB) OF 3,100 PSI. THE
MINIMUM ALLOWABLE COMPRESSION STRESS (FC) PERPENDICULAR TO THE GRAIN SHALL BE 750 PSI. THE MINIMUM
ALLOWABLE MODULUS OF ELASTICITY (E) SHALL EE 2. 00,000 PSI. INSTALL LVL'S IN STRICT ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS.
8. USE 3/4' THICK TONGUE AND GROOVE "STRUCTU I" GRADE FIR PLYWOOD FLOOR SHEATHING.
9. PROVIDE SOLID BLOCKING BETWEEN ALL FLOOR JOISTS AND DOUBLE ALL JOISTS UNDER EACH PARTITION. EACH END OF
EACH JOIST SHALL BE FULL DEPTH BLOCKED AT THE SUPPORT LOCATION. PROVIDE JOIST BRIDGING AT THIRD -SPANS
POINTS, OR AS SHOWN ON DRAWINGS. BRIDGING PLACEMENT SHAD_ NOT EXCEED 8 FT. O.C. SPACING.
10. USE FULLY NAILED METAL CONNECTORS (USP, SIMPSON, OR EQUAL), JOIST, OR BEAM HANGERS WHEN JOISTS OR
BEAMS FRAME INTO OTHER JOISTS OR BEAMS. PROVIDE METAL POST CAPS AND BASES FOR ALL POSTS.
11. ALL PLYWOOD FLOOR SHEATHING SHALL BE CLUED] TO SUPPORTING WOOD FRAMING MEMBERS USING AMERICAN
PLYWOOD ASSOCIATION (A.PA.) GLUED FLOOR SYSTEM. WOOD GLUE TO BE CONTECH, INC., PL400 SUBFLOOR CONSTRUCTION
ADHESIVE, OR APPROVED EQUAL
12. ALL NAILS, FASTENERS, AND CONNECTORS EXPOS TO THE WEATHER SHALL BE HOT -DIP GALVANIZED. ALL
CONNECTORS AND FASTENERS WHICH ARE USED KM RESSURE TREATED WOOD SHALL BE AISI 304 OR 316 STAINLESS
STEEL
28. ALL WOOD PRODUCTS SHALL BE STORED IN A D LOCATION. ENGINEERED LUMBER PRODUCTS WHICH ARE NOT KEPT
DRY WILL BE IMMEDIATELY REJECTED AND REQUTtED BE REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST.
30. IN NO CASE SHALL JOISTS OR ANY OTHER FRAMING MEMBER BE CUT, NOTCHED, DRILLED, OR OTHERWISE MODIFIED
WITHOUT THE WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER.
31. JOISTS WHICH SUPPORT MECHANICAL UNITS SHALL BE TRIPLED AND NAILED TOGETHER AS SPECIFIED, UNLESS
OTHERWISE SHOWN OF THE FRAMING PLANS C UETAI
"ISSUED FOR CONSTRUCTION"
OASTAL
STRUCTURAL GENERAL NOTES CONCRETE NOTES !FOUNDATION AND SLABS-ON-
1. ALL STRUCTURAL WORK SHALL BE COORDINATED WITH THE ARCHITECTURAL PLANS DATED 06/04/07 PREPAIRD BY SARA 1. CONCRETE MIXTURE, FORM -WORK, DELIVERY AN
MW
PLACEMENT SHALL CONFORM TO ALL REQUIREMENTS OF ACI 301
260 Cranberry Hwy. Orleans, MA 02653
508.255.6511 Fax: 508155.6700
PORTER; YARMOUTH PORT, MA. AND SPECIFICATIONS AND SHALL CONFORM TO THE PROJECT SPECIFICATIONS, INCLUDING (LATEST EDITION), UNLESS OTHERWISE NOTED.
THE FOLLOWING GOVERNING STANDARDS:
2. CONCRETE MATERIALS SHALL BE: TYPE 1 OR 2
PORTLAND CEMENT, SAND AND GRAVe$. AGGREGATES. CONCRETE SHALL
A THE MASSACHUSETTS STATE BUILDING CODE, SIXTH EDITION, AND ALL OTHER AGENCIES HAVING JURISDICTION. BE AIR -ENTRAINED PER ACI RECOMMENDATIONS. CONCRETE
COMPRESSIVE STRENGTH, (rC) IN 28 DAYS, WHEN TESTED IN
ACCORDANCE WITH ACI 318-05, SHALL BE AS FO
DWS: ALL CONCRETE WORK - 4,000 PSI
B. ACI "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE' (ACI 318 -OS)
3. THE MAXIMUM CONCRETE SLUMP FOR FOUNDATION
WALLS, FOOTINGS, PIERS, ETC., SHALL Be 4". THE MAXIMUM
a�
U
C. THE TIMBER CONSTRUCTION MANUAL, 4TH EDITION," AMERICAN FOREST & PAPER ASSOCIATION. CONCRETE SLUMP FOR SLABS SHALL BE 30. ALL
CONCRETE SHALL BE AIR ENTRAINED TO 6% (+/- 17).
D. THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, LATEST EDITION. 4. ALL MIXING, TRANSPORTING, PLACING AND CUR114G
OF CONCRETE SHALL BE DONE IN ACCORDANCE WITH THE
RECOMMENDATIONS OF THE CURRENT AMERICAN CONCRETE
INSTITUTE SPECIFICATIONS AND GUIDELINES.
2. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND BRACING AND MAKE SAFE ALL FLOORS, ROOFS, WALLS AND
ADJACENT PROPERTY AS PROJECT: CONDITIONS REQUIRE. 5. REINFORCING STEEL SHALL BE NEW DEFORMED
BARS CONFORMING TO ASTM A615, GRADE 60, EXCEPT WHERE NOTED.
ALL REINFORCING BARS WELDED TO A STEEL SECTION
SHOULD BE OF WELDING GRADE 40. RUSTED BARS WILL BE
3. ALL CONSTRUCTION IS TO CONFORM TO THE MASSACHUSETTS STATE BUILDING CODE AND ALL APPLICABLE PRODUCT AND IMMEDIATELY REJECTED AND REQUIRED TO BE REPLACED
AT NO ADDITIONAL COST.
O
F
DESIGN STANDARDS. ABSENCE OF SPECIFIC ITEMS FROM THESE DRAWINGS DOES NOT INFER THAT THE CONTRACTOR IS
RELIEVED FROM THE STATUTORY CODE REQUIREMENTS. 6. DETAILING OF CONCRETE REINFORCEMENT AND
ACCESSORIES SHALL BE IN ACCORDANCE WITH ACI PUBLICATION 315 AND
CURRENT CRSI SPECIFICATIONS, LATEST EDITIONS.
4. ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL CONFORM TO THE APPROVED RULES AND STANDARDS FOR
MATERIALS, TESTS, AND REQUIREMENTS OF ACCEPTED ENGINEERING PRACTICE AS LISTED IN APPENDIX A OF THE 7. WELDED WIRE MESH (WWM) SHALL BE NEW AND
FREE FROM RUST, CONFORMING TO ASTM A185 WITH A MINIMUM
MASSACHUSETTS STATE BUILDING CODE. TENSILE STRENGTH OF 70,000 PSI. REFER TO PLAN
FOR SIZES.
5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO COMMENCING WORK. ANY 8. PROVIDE MINIMUM TEMPERATURE REINFORCEMENT
AS REQUIRED BY ACI 318-05, IN ALL SLABS AND WALLS WHERE NO
0
a
DISCREPANCY BETWEEN WHAT IS SHOWN ON THE DRAWING AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED BACK TO REINFORCEMENT IS INDICATED ON DRAWINGS.
THE ENGINEER IN WRITING BEFORE PROCEEDING WITH ANY WORK.
9. UNLESS OTHERWISE SHOWN ON THE DRAWINGS,
REINFORCING STEEL SHALL BE PLACED TO PROVIDE THE FOLLOWING
6. OPENINGS THROUGH THE FRAMING AND FOUNDATION MAY NOT ALL BE SHOWN ON THESE DRAWINGS. THE GENERAL MINIMUM CONCRETE COVER:
CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL DRAWINGS FOR THE REQUIRED OPENINGS AS HE SHALL PROVIDE BOTTOM FOOTINGS 3'
c>~
SEAL
ADDITIONAL FRAMING AND REINFORCING STEEL FOR ALL OPENINGS WHERE REQUIRED. THE GENERAL CONTRACTOR SHALL FORMED I
SIDES FOOTINGS 2'
F.
VERIFY SIZE AND LOCATION OF ALL OPENINGS. ANY DEVIATION FROM THE OPENINGS SHOWN ON THE STRUCTURAL DRAWINGS
FOUNDATION WALLLS 1 1/2'
L
O
in,
SHALL BE BROUGHT TO THE ENGINEERS IMMEDIATE ATTENTION FOR REVIEW. SLAB ON GRADE 2" BELOW TOF
SURFACE
7. DESIGN VERTICAL LIVE LOADS: 10. SILL PLATE ANCHORS (AS SIZED ON DWGS.) TD
BE ASTM A307 GRADE A' STEEL OR AISI 304, 316 STAINLESS STEEL
ROOF: BOLTS EMBEDDED INTO TOP OF CONCRETE FOUNDATION
- SNOW LOAD RAFTER AREAS: 3D PSF (PLUS SNOW DRIFT AND SLIDING SNOW CRITERIA PER MASS. CODE SECT.
WALL AT MAXIMUM SPACING OF 4 FT. ON CENTER AND 6 IN.
MAXIMUM FROM EACH DISCONTINUOUS END, UNLESS
NOTED OTHERWISE. REFER TO DRAWING DETAIL ALL HOOKED ANCHOR
�
1610). BOLTS SHALL BE EMBEDDED 12' MIN. INTO CONCRETE.
ATTIC: 11. ALL CONTINUOUS REINFORCEMENT SHALL HAVE
CLASS 'B' SPLICES (ACI 318-05, SECTION 12.15) OR SHALL BE
- 20 PSF LAPPED 40 BAR DIAMETERS MINIMUM, UNLESS NO
ED OTHERWISE.
FIRST FLOOR: 14. HORIZONTAL WALL AND FOOTING REINFORCING
SHALL BE CONTINUOUS AND SHALL HAVE 90 -DEGREE BENDS ON
- 40 PSF EXTENSIONS AT CORNERS AND INTERSECTIONS; OR
PROVIDE 2'-0' X 2'-0" CORNER BARS SIZE TO MATCH, AS SHOWN ON
9. NOTIFY THE ENGINEER OF ANY ARCHITECTURAL MODIFICATION OR DIMENSION CHANGES THAT MAY AFFECT THE TYPICAL BAR PLACING DETAILS.
STRUCTURAL DESIGN. 15. ALL LAP SPLICES IN WWM SHALL BE 8' MINIM
JM OR ONE MESH SPACE PLUS 2' IN EACH DIRECTION.
10. THE FOLLOWING ASSUMED SOIL PROPERTIES HAVE BEEN USED FOR THE FOUNDATION AND SLAB -ON -GRADE DESIGN.
Q
- UNIT WEIGHT OF SOIL 120 PCF 16. REINFORCING BARS MAY NOT BE WELDED WITH
UT APPROVAL OF THE STRUCTURAL ENGINEER. WHEN APPROVED,
0 �
- SOIL BEARING CAPACITY: 1.5 TONS/SF WELDING OF REINFORCING BARS SHALL BE IN ACC
RDANCE WITH THE CURRENT A.W.S.
- ULTIMATE FRICTION FACTOR: 0.45
50 PCF 17. ALL CONCRETE SHALL BE PROTECTED AGAINST
- MINIMUM SUBGRADE MODULUS: 2 250
FROST UNTIL PROJECT: IS COMPLETED. PROVIDE PROPER CONCRETE
DATE
08/03/07
PROTECTION OR HEAT IN COLD WEATHER AND MAINTAIN
PROPER CURING PROCEDURES IN ACCORDANCE WITH ALL CURRENT
S�o
ACI CODE OF STANDARD PRACTICE SPECIFICATIONS
AND GUIDELINES.
18. ALL REINFORCING BARS SHALL BE COLD BENT
IN ACCORDANCE TO THE PROPER RADII ESTABLISHED BY THE ACI. UNDER
NO CIRCUMSTANCES SHALL HEAT BE APPLIED TO THE
BARS TO OBTAIN BENDS.
19. FORMS SHALL BE OILED PRIOR THEIR THE ERECTION.
REINFORCING BARS WHICH ARE COATED WITH FORM OIL OR ANY
OTHER BOND BREAKING MATERIAL WILL BE REJECTED
AND WILL REQUIRE REPLACEMENT AT NO ADDITIONAL COST TO THE
OWNER.
20. CONCRETE MAY CONTAIN FLY -ASH. IF PROPOSED
IN MIX DESIGN, EACH SHALL SATISFY ALL ACI AND ASTM CURRENT
REQUIREMENTS AND SPECIFICATIONS.
21. ADDITION OF WATER TO CONCRETE MIXES AT THE
SITE IS NOT ALLOWED. SUCH CONCRETE SHALL BE IMMEDIATELY
REJECTED.
22. ALL CONCRETE SHALL BE READI-MIXED AT P�NT
COMPLYING WITH ASTM C94 AND ASTM C1116. SITE MIXING IS NOT
ALLOWED.
23. THE USE OF CONTROL JOINTS IN THE SLABS
WIDE TO A DEPTH OF 1/4 SLAB THICKNESS WITH
CLEAN AND PREPARE JOINTS AND FILL SOLID WIT
OR AN APPROVED EQUAL REINFORCING STEEL SH
24. CHAIR BARS FOR SECURE PLACEMENT AND P
BRICK, WOOD, OR OTHER NON -CONFORMING REIN
SUPPORT CHAIRS SHALL BE 18" IN EACH DIRECT]
a
v
0
N
O
R
i REQUIRED TO CONTROL CRACKING. SAW CUT CONTROL JOINTS 1/4-
48 HOURS OF CONCRETE PLACEMENT. AFTER CONCRETE HAS CURED,
'SIKADUR 51 SL.FLEXIBLE EPDXY CONTROL JOINT RESIN" (SIKA CORP.)
1 EXTEND CONTINUOUS THROUGHSLAB AT CONTROL JOINTS.
TIIONING OF REINFORCING STEEL IS TO BE PROVIDE IN NO CASE SHALL
IRCING STEEL SUPPORTS BE USED. MA'UMUM SPACING OF MESH
t ,1
WOOD FRAMING NOTES
1. ALL FRAMING LUMBER SHALL CONFORM TO THE LATEST EDITION OF THE NFPA "NATIONAL DESIGN SPECIFICATION FOR
WOOD CONSTRUCTION", AND SUPPLEMENT 'DESIGN VALUES FOR WOOD CONSTRUCTION', LATEST EDITION. MAXIMUM MOISTURE
CONTENT SHALL BE 19%.
2. ALL WOOD MEMBERS USED FOR PLACEMENT AGAINST CONCRETE OR MASONRY (SILLS, PLATES, ETC.) SHALL BE
PRESSURE TREATED WITH ACO PRESERVATIVE, OR APPROVED EQUAL, TO MINIMUM RETENTION OF 0.6 PCF IN ACCORDANCE
WITH AWPA C3.
3. THE FRAMING LUMBER SHALL BE OF THE FOLLOWING MINIMUM GRADE AND SPECIES FOR THE SPECIFIED USE. ALL
LUMBER SHALL BE GRADE STAMPED BY A RECOGVIZED GRADING AGENCY AND SHALL BE KILN DRY:
s PRESSURE TREATED: SOUTHERN PINE GRADE NO. 2, OR BETTER, WITH A MINIMUM ALLOWABLE BENDING STRESS (FB) -975
PSI AND MINIMUM MODULUS OF ELASTICITY (E)m1,600,000 PSI.
• NON PRESSURE TREATED:
4. DETAILS OF WOOD FRAMING SUCH AS NAILING, BLOCKING, BRIDGING, FIRESTOPPING, ETC. SHALL CONFORM TO THE
LATEST EDITION OF THE NATIONAL DESIGN SPECIFCATION (NFPA), THE TIMBER CONSTRUCTION MANUAL (ARC), AND
ARCHITECTURAL GRAPHICS STANDARD BY RAMSEY & SLEEPER.
5. ALL ENGINEERED LUMBER PRODUCTS SHALL B- AS MANUFACTURED BY THE TRUSS JOIST CORPORATION, BOISE CASCADE,
LOUISIANA PACIFIC CORPORATION OR APPROVED EQUALL
6. FOLLOW MANUFACTURERS' SPECIFICATIONS FOR ERECTION, INSTALLATION, AND PLACEMENT OF ENGINEERED LUMBER
PRODUCTS. PENETRATIONS THROUGH ENGINEERED LUMBER PRODUCTS IS EXPRESSLY NOT PERMITTED WITHOUT PRIOR
WRITTEN APPROVAL BY THE ENGINEER.
7. ALL LAMINATED VENEER LUMBER (LVL) TO HANE A MINIMUM ALLOWABLE BENDING STRESS (FB) OF 3,100 PSI. THE
MINIMUM ALLOWABLE COMPRESSION STRESS (FC) PERPENDICULAR TO THE GRAIN SHALL BE 750 PSI. THE MINIMUM
ALLOWABLE MODULUS OF ELASTICITY (E) SHALL EE 2. 00,000 PSI. INSTALL LVL'S IN STRICT ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS.
8. USE 3/4' THICK TONGUE AND GROOVE "STRUCTU I" GRADE FIR PLYWOOD FLOOR SHEATHING.
9. PROVIDE SOLID BLOCKING BETWEEN ALL FLOOR JOISTS AND DOUBLE ALL JOISTS UNDER EACH PARTITION. EACH END OF
EACH JOIST SHALL BE FULL DEPTH BLOCKED AT THE SUPPORT LOCATION. PROVIDE JOIST BRIDGING AT THIRD -SPANS
POINTS, OR AS SHOWN ON DRAWINGS. BRIDGING PLACEMENT SHAD_ NOT EXCEED 8 FT. O.C. SPACING.
10. USE FULLY NAILED METAL CONNECTORS (USP, SIMPSON, OR EQUAL), JOIST, OR BEAM HANGERS WHEN JOISTS OR
BEAMS FRAME INTO OTHER JOISTS OR BEAMS. PROVIDE METAL POST CAPS AND BASES FOR ALL POSTS.
11. ALL PLYWOOD FLOOR SHEATHING SHALL BE CLUED] TO SUPPORTING WOOD FRAMING MEMBERS USING AMERICAN
PLYWOOD ASSOCIATION (A.PA.) GLUED FLOOR SYSTEM. WOOD GLUE TO BE CONTECH, INC., PL400 SUBFLOOR CONSTRUCTION
ADHESIVE, OR APPROVED EQUAL
12. ALL NAILS, FASTENERS, AND CONNECTORS EXPOS TO THE WEATHER SHALL BE HOT -DIP GALVANIZED. ALL
CONNECTORS AND FASTENERS WHICH ARE USED KM RESSURE TREATED WOOD SHALL BE AISI 304 OR 316 STAINLESS
STEEL
28. ALL WOOD PRODUCTS SHALL BE STORED IN A D LOCATION. ENGINEERED LUMBER PRODUCTS WHICH ARE NOT KEPT
DRY WILL BE IMMEDIATELY REJECTED AND REQUTtED BE REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST.
30. IN NO CASE SHALL JOISTS OR ANY OTHER FRAMING MEMBER BE CUT, NOTCHED, DRILLED, OR OTHERWISE MODIFIED
WITHOUT THE WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER.
31. JOISTS WHICH SUPPORT MECHANICAL UNITS SHALL BE TRIPLED AND NAILED TOGETHER AS SPECIFIED, UNLESS
OTHERWISE SHOWN OF THE FRAMING PLANS C UETAI
"ISSUED FOR CONSTRUCTION"
OASTAL
NGINEERING
I
OMPANY, INC.
260 Cranberry Hwy. Orleans, MA 02653
508.255.6511 Fax: 508155.6700
x
U
a�
U
O
O
F
W
0
a
0
0
c>~
SEAL
F.
O
in,
U
W
Ew-'
Q
�
E -I
Q
u
0 �
W
a N
SCALE
AS NOTED
DESIGNBY
.1llm
DATE
08/03/07
DRAWNBY
APC
CHECKED BY
TAB
S�o
I OF 3 SHEETS
PROB?CT. NO.
C16933.00