HomeMy WebLinkAbout47 Raymond Ave - Septic System Designi. _. .. .a �.r ..a-.-. '�.. ..... a>.4...,.-«...+-.. yr a. wa•rv'w. a,. e.». .. ... .. ..... r.m +r..�..�..-n-e v'^.-`-F.-a-.e ACCESS COVERS MUST BE WITHIN 91 MIIMUM, INVERT ELEVATIONS: DESIGN CRITERIA: GENERAL NOTES ' 6' OF FINISH GRADE 3' MA IMUM COVER 1 100.8 FIRST 2' TO INVERT AT BUILDING: 98.8 DESIGN FLOW: BE LEVEL MIN 2. OF PEASTONE' INVERT IN SEPTIC TANK: 97.5 5 BEDROOMS AT 110 G.P.D. PER I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION 3 INVERT OUT SEPTIC TANK: 97.25 BEDROOM EOUALS 550 G.P.D. OF THE SEWAGE DISPOSAL SYSTEM ONLY. +- Df M PIP INVERT IN 01ST. 80X: 97.1 3/4' 1 I/2' DIA. ��- $$ �, DOUBL WASHED STONE INVERT OUT DIST. BOX: 96.93 NO GARBAGE GRINDER 2. VERTICAL DATUM !S ASSUMED. FOR BENCH MARKS B. - 7. 5 96.93 2' 7 5 BAFFLE 97 1' c 96.5 $ INVERT IN LEACH CHAMBER: 96.5 SEPTIC TANK REQUIRED: SET. SEF SITE PLAN. 4-500 GAL LEACHING CHAMBERS BOTTOM OF LEACH CHAMBER: 94.5 550 G.P.D. X 200x - 1100 GAL. � 3 OUTLET 3. ALL CONSTRUCTION METHODS AND MATERIALS AND D-BOX W/4' STONE AROUND. 12.8'r x 42'1 x 2'd ADJUSTED GROUND WATER: N/A SEPTIC TANK PROVIDED: 1500 GAL. MIN. MAINTENANCE OF THE SEPTIC SYSTEM SHALL 1500 GAL OBSERVED GROUND WATER: N/A CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL SEPTIC TANK 6" CRUSHED STONE OR BOTTOM OF TEST HOLE •I: 88.7 SOIL ABSORPTION SYSTEM REQUIRED: BOARD OF HEALTH REGULATIONS. COMPACTED BASE Iv DESIGN PERC RATE ( 5 MIN/INCH PROFILE:NOT TO SCALE s. SOIL TEXTURAL CLASS - 1 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER i <3 EFFLUENT LOADING RATE - 0.74 GPD/SF AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER 550 GPD / 0.74 GPD/SF - 743 S.F. REDUIRED THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING N-20 WHEEL LOADS. PROVIDED: 4-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-756 S.F. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR T T 756 S.F. x 0.74 - 560 G.P.D. APPROVED EQUAL. 1\VI 6. SEPTIC TANK AND D-BOX SHALL BE REINFORCED SO I L TEST PIT DA TA & PRECAST CONCRETE AND WATERTIGHT. O-BOX SHALL INDICATES INDICATES BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE PERCOLATION = OBSERVED IS MORE THAN ONE OUTLET. TEST GROUNDWATER 7. BEFORE CONSTRUCTION CALL -DIG-SAFE". TP •I CB/pH-FND' OCATCH ASfN I-888-DIG-SAFE AND THE LOCAL WATER DEPT. N 79.15.20'E0. HORIZON TEXTURE COLOR 98.7 FOR LOCATION OF UNDERGROUND UTILITIES. 99.0 CAT BASIN LOAMY IOYR 110-30® � A 8: EXISTING CESSPOOLS TO BE PUMPED DRY. REMOVED SAND 2/2 AND BACKFILLED WITH SAND. i \ CB/OH FND 16 • ........... .......... ... .YR 97.4 .SAC / o ��` r� D LOAMY 10YR +.� D SAND 4/6 9• NO DETERMINATION HAS BEEN MADE AS TO Br --500 GALLON \ COMPLIANCE WITH DEED RESTRICTIONS OR ZONING !D' .'12' LEACHING CHAMBERS y 26- .......... ....... ......... 96.5 11/4' SrONF AROUND a ClMEDIUM 1.5Y REGULATIONS. IT SHALL REMAIN THE CLIENTS ,. BM-COR BULKHEAD O SAND 5/4 RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL EL-100.51 PERMITS. VARIANCES ETC. FOR THIS PROJECT, e 7- b o 00 68' TPII m m N m a - 22 D-BOX to - _._.... esoo eat- m SEPTfC,/f4NK� � o x � z-�} m. N .:~ •0 2 w 112 20 NO WATER 88.7 CESSPOOLS m 30'. , 5• DATE: APRIL !0. 2003 TEST BY: STEPHEN HAAS o It'0AK =` � WITNESSED BY: AMY VONHONE z o _ rcp r GAS AErE FERC RATE: (2 MIN/INCH % i E / PAVED DR,,ENA E x Y CB/DH FNI UP 311/5 Y 003 113.02 •W �y IL 1 / 5 79' , •2d SEPT/C SYSTEM DES /G/V 47 RA YMOMD A VENUE . MA P 79 . PA RL 2-5 T1--1 YA R"O U TI-1, MA . PREPARED FOR . CHR / S 7-H0M! S r+r L OCUS�" E . SCAL: / "- 20 APRIL 30. 2003 D-Y HIGH i 1 ?� ` ry EAGLE SIJRVEY I NG I NC ,. .SCHOOL Zj - r' . / > A`E /ONAGi AVE' 92 3 R o u t e 6 A f� r VAR I ANCES REQUIRED: G Yarmouthport MA. 02675 311�i%� :508 j 362-8 1 32 TITLE S. MAXIMUM FEASIBLE COMPLIANCE�jy�5v/63 //j/j ( 508) 432-5333 SECTION 15.211:111 MINIMUM SETBACK DISTANCES l `''�'� ✓� / 10'IS REQUIRED BETWEEN THE SAS AND THE PROPERTY LINE. 7' IS PROVIDED. A 3' VARIANCE IS REOUESTED TO SAVE THE 12" CALIPER OAK TREE. 1 LOCUS -MAP 0 10 20 40 JOB NO: 03-027 FIELD:CFW/EEK CALC: SAH CHECK: CFW DRN SAH