HomeMy WebLinkAbout47 Raymond Ave - Septic System Design 2ACCESS COVERS MUST BE WITHIN 6' OF FINISH GRADE 9- MINIMUM. 3' MAXIMUM COVER 100.8 FIRST 2' TO BE LEVEL MIN 2. OF PEASTONE 4' DJAM PIPP 3/4- - 1 1/2' DIA. 97. 5 96.93 T2' �" DOUBLE WASHED STONE -T rAs 1 -- 'D 94_5 - 3 OUTLET 4-500 GAL LEACHING CHAMBERS V6, D -BOX W/4' STONE AROUND. 12.8'. x 42'1 x Z'd 1500 GAL SEPTIC TANK CRUSHED STONE OR COMPACTED BASE PROFILE : NOT TO SCALE LOCUS.,}, J D -Y NJpI � G}IODL JD � A 7 VARIANCES REQUIRED: TITLE 5. MAXIMUM FEASIBLE COMPLIANCE SECTION 15.2/1:(!) MINIMUM SETBACK DISTANCES / r 10'IS REQUIRED BETWEEN THE SAS AND THE PROPERTY LINE. 7' IS PROVII A 3' VARIANCE IS REQUESTED TO SAVE THE 12' CALIPER OAK TREE. LOCUS MAP ___l . s �.. .'v. a.♦..y1y:r ., .. �. .. a - 's 1'..: .. .. �.t -...: , L [. ,v +i ..,. ♦. ,. .M' .:. �.; �.. i♦n.♦ , .:. 4.' L q. .. :... v......: -.<-A. f... .....» _. a.. ..'v. ,t a-._.ud-. T..:....fi:_.- - .F '... -,. .a '. :'_..♦ .. < .. a_ .. ._. .,.... -. ..,.. .... v. .. ♦ay. .s. INVERT ELEVATIONS: INVERT AT BUILDING: 96.6 INVERT IN SEPTIC TANK: 97.5 INVERT OUT SEPTIC TANK: 97.25 INVERT IN DIST. BOX: 97.1 INVERT OUT DIST. BOX: 96.93 INVERT IN LEACH CHAMBER: 96.5 BOTTOM OF LEACH CHAMBER: 94.5 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE •l: 88.7 I DESIGN CRITERIA: DESIGN FLOW: 5 BEDROOMS AT 110 G.P.D. PER BEDROOM EQUALS 550 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 550 G.P.D. X 2002 - 1100 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ( 5 MIN/INCA SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 550 GPD / 0.74 GPD/SF - 743 S.F. REQUIRED PROVIDED: 4-500 GAL LEACHING CHAMBERS W/4' STONE AROUND, A-756 S.F. 756 S.F. x 0.74 - 560 G.P.D. GENERAL NOTES: I 2 3 4 5 SOIL TEST PIT DA TA & 6 INDICATES 7 1NDICATES PERCOLATION OBSERVED TEST GROUNDWATER 7 TP *1 0- HORIZON TEXTURE COLOR 98.7 8 Q LOAMY IOYR SAND 2/2 16 .......................................... 97.4 LOAMY IOYR B SAND 4/6 9 26' .......................................... 96.5 C r MEDIUM 2.SY SAND 5/4 ME 120.1 NU PFA rtrc L 88.7 DATE: APRIL 10. 2003 TEST BY: STEPHEN HAAS WITNESSED BY: AMY YONHONE PERC RATE: ( 2 MIN/INCH THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS, D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D -BOX SHALL BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. BEFORE CONSTRUCTION CALL -DIG-SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. EXISTING CESSPOOLS TO BE PUMPED DRY. REMOVED AND BACKFILLED WITH SAND. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS, VARIANCES ETC. FOR THIS PROJECT. SEPT/C SYSTEM OES /G/\/ 47 RA YM0/V0 A VENUE . "A P 70. PA RCEL 25 SOV TH Yet RMO U 7"/--/. "A . PREP.4 REO FOR CHR / S - THOM,q S .5CAL E / " — 20 APR / L 30 - 2003 i.> EAGLE SURVEY I NO I NC Route 6A Ya rrriou t h p a r t MA 02675 ( 508) 362-8132 ,( 508) 432-5333 1 D to 2Q 4v JOB N0: 03-027 FIELD:CFW/EEK CALC: SAN CHECK: CFW DRN: SAH