HomeMy WebLinkAbout47 Raymond Ave - Septic System Design 3ACCESS COVERS MUST BE WITHIN 9" MINIMUM. INVERT ELEVATIONS: DESIGN CRITERIA: GENERAL NOTES: 6' OF FINISH GRAD i MAXIMUM COVER 100.6 FIRST 2' TO 98.8 INVERT AT BUILDING: DESIGN FLOW; - BE LEVEL MIN 2* OF PEASTONE INVERT IN SEPTIC TANK: 97.5 5 BEDROOMS AT 110 G.P.D. PER I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION INVERT OUT SEPTIC TANK: 97,25 BEDROOM EQUALS 550 G.P.D. OF THE SEWAGE DISPOSAL SYSTEM ONLY. 4- OIAV PIPE 314" - I fl2* DIA. INVERT IN DIST. BOX: 97.1 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS 97.25 9 T2' SET, SEE SITE PLAN. INVERT IN LEACH CHAMBER: 96.5 6. DOUBLE WA STONE INVERT OUT DIST. BOX: 96.93 NO GARBAGE GRINDER CAB I 1 1 94.5 7� 7 p 6.5 SEPTIC TANK REQUIRED: BOTTOM OF LEACH CHAMBER: 94.5 4-500 GAL LEACHING CHAMBERS 3 OUTLET 550 G.P.D. X 200V - 1/00 GAL. J. ALL CONSTRUCTION METHODS AND MATERIALS AND U_ffux W14* STONE AROUND. 12.8'r x 42*1 x 2*d ADJUSTED GROUND WATER: NIA SEPTIC TANK PROVIDED: 1500 GAL. MIN. MAINTENANCE OF THE SEPTIC SYSTEM SHALL 1500 GAL 08SERVED GROUND WATER: NIA CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL SEPTIC TANK 6' CRUSHED STONE OR BOTTOM OF TEST HOLE 68.7 SOIL ABSORPTION SYSTEM REQUIRED: BOARD OF HEALTH REGULATIONS. COMPACTED BASE DESIGN PERC RATE ( 5 MIN/INCH SOIL TEXTURAL CLASS - 1 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER PROFILE:NOT TO SCALE EFFLUENT LOADING RATE - 0.74 GPD/SF AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER 550 GPD / 0.74 GPD/SF - 743 S.F. REQUIRED THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. j PROVIDED: 4-500 GAL LEACHING CHAMBERS W14' STONE AROUND, A-756 S.F. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR 2 20756 S.F. x 0.74 - 560 G.P.D. APPROVED EQUAL. 6. SEPTIC TANK AND D-BOX SHALL BE REINFORCED SOIL TEST PIT DA TA PRECAST CONCRETE AND WATERTIGHT. D-SOX SHALL INDICATES I NO I CA TES BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE PERCOLATION OBSERVED IS MORE THAN ONE OUTLET. TEST GROUNDWATER 7. BEFORE CONSTRUCTION CALL 'DIG-SAFE'. C61W-KND gCATCH BASIN TP 1-688-DIG-SAFE AND THE LOCAL WATER DEPT. F o 79 .15-20'r 0" HORIZON TEXTURE COLOR 98.7 OR LOCATION OF UNDERGROUND UTILITIES. 99,010 30, WATCH BASI I A LOAMY IOYR _ 6. EXISTING CESSPOOLS TO BE PUMPED DRY. REMOVED SAND 212 AND BACKFILLED WITH SAND. ... . ......... ... .... ...... - 97.4 CB/DH FNDLOAMY IOYR SAND 416 9. NO DETERMINATION HAS BEEN MADE AS TO - KsOO GALLON 26, ............... ..... _­ 96.5 COMPLIANCE WITH DEEP RESTRICTIONS OR ZONING LEACHING CHAMBERS MEDIUM UM 2.5Y Cl REGULATIONS. IT SHALL REMAIN THE CLIENTS F14' STONE AROUND SAND 514 RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL SM-COR BULKHEAD EL-100.54 PERMITS. VARIANCES ETC. FOR THIS PROJECT. 681 D Box 10 o % i5oo GAL SEPTIC/N 0 1201 NO WATER 8.7 CESSPOOLS DATE: APRIL 10. 2003 o I2'OAKTEST BY: STEPHEN HAAS 0 ;2'OAK Z WITNESSED BY: AMY VONHONE too, r GAS ETC PERC RATE: 2 MIN/INCH 7 �j PAVED DB IVEwA E, CB/DH PAID UP 311/5 13.o2* S 79.11 5 E_ F:l T C SYSTEM ZD E_ 15 (a VENUE . MAP 7r 9� PAR CEL 25 4 7 PA )�MCIVD A VdE S 0 L/ TI-1 YARMOUTH. "A PREPARED FOR L Ocus­�� �11 t; N/ w, SCALE A PR L .30 2003 0-Y HIGH V E I N G I NC EAGLE S U R 923 Route 6A Yc rrnc�u t h po r t MA 02675 VARIANCES REQUIRED: (508) 362-8132 TITLE 5. MAXIMUM FEASIBLE COMPLIANCE3 (508) 432-5333 SECTION 15.211:(1) MINIMUM SETBACK DISTANCES 10'IS REQUIRED BETWEEN THE SAS AND THE PROPERTY LINE. 7 IS PROV ED. A 3' VARIANCE /S REQUESTED TO SAVE THE 12* CALIPER OAA TREE• LOCUS MAP. 0 10 20 40 IJOB NO: 03-027 1 FIELD:CFWIEEK CALL: SAH CHECK: CFIV DRN: SAH mt I