Loading...
HomeMy WebLinkAbout47 Raymond Ave - Septic System Design 4100.8 ACCESS COVERS MUST BE WITHIN 6. OF FINISH GRADE. C,A$ 9 MINIMUM. I N VER T ELEVATIONS: DESIGN CRITERIA: GENERAL NOTES:I 3 MAXIMUM COVER FIRST 2' TO BE LEVEL y -MIN 2- OF PEASTONE 3/4- - 1 1/2' DIAr DOUBLE WASHED STONE 3 OUTLET 4-500 GAL LEACHING CHAMBERS 1500 GAL D -BOX W/4" STONE AROUND. I2.8". x 42"I x 2'd SEPTIC TANK 6' CRUSHED STONE OR COMPACTED BASE PROFILE : NOT TO SCALE INVERT AT BUILDING: 98.8 IPVERT IN SEPTIC TANK: 97.5 INVERT OUT SEPTIC TANK: 97.25 11VVERT IN DIST. BOX: 97.1 IV VERT OUT DIST. BOX: 96.93 INVERT IN LEACH CHAMBER: 96.5 BOTTOM OF LEACH CHAMBER: 94.5 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE •1: 88.7 i Y - v5 N DESIGN FLOW 5 BEDROOMS AT 110 G.P.D. PER I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION BEDROOM EQUALS 550 G.P.D. OF THE SEWAGE DISPOSAL SYSTEM ONLY. NO GARBAGE GRINDER 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS 97.4 SET. SEE S1 TE PLAN. SEPTIC TANK REQUIRED: D SAND 4/6 550 G.P.D. X 200% - 1100 GAL. J. ALL CONSTRUCTION METHODS AND MATERIALS AND SEPTIC TANK PROVIDED: 1500 GAL. MIN. MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL SOIL ABSORPTION SYSTEM REQUIRED: BOARD OF HEALTH REGULATIONS. DESIGN PERC RATE l 5 MIN/INCH SOIL TEXTURAL CLASS - 1 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER EFFLUENT LOADING RATE - 0.74 GPD/SF AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER 550 GPD / 0.74 GPD/SF - 743 S.F. REQUIRED THAN 3' 1N DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. PROVIDED: 4-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-756 S.F. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR 756 S.F. x 0.74 - 560 G.P.D. APPROVED EQUAL. SOIL TES T PIT DA TA & 6 INDICATES INDICATES PERCOLATION _ OBSERVED TEST GROUNDWATER 7 TP • 1 0- HORIZON TEXTURE COLOR LOAMY IOYR 98.7 SAND 2/2 16* ........... _............................. 97.4 3 LOAMY IOYR D SAND 4/6 26*-- ............ ....:.......... 96.5 C I MEDIUM 2.SY SAND 5/4 120'1 NO WATER 1 88.7 DATE. APRIL l0. 2003 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: l 2 MIN/INCH 0 SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D -BOX SHALL BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. BEFORE CONSTRUCTION CALL -DIG-SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. EXISTING CESSPOOLS TO BE PUMPED DRY. REMOVED AND BACKFILLED WITH SAND. 9. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULA TIONS: IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. i SEPT/C SYSTEM DES /GN j 47 RA YMO/V0 A VENUE . MAP 70. PAR CEL 2.5 S O U TH YA RMO U TH , "A LOCUST SCALE: / 20 APRIL 30. 2003 D -Y MayCHOM 10IAA l ��,.�SA 'eiF�.T,. .EAGLE SURVEY I NG , I NC 923 Route 6A VARIANCES ANCES REQUIRED : � . `"'� == Yarrnouthport rMA. 02675 3 (508) 362-8132 TITLE 5. MAXIMUM FEASIBLE COMPLIANCE J ( 508 ) 432-5333 SECTION /5.211:(1! MINIMUM SETBACK DISTANCES 1 10'/S REQUIRED BETWEEN THE SAS AND THE PROPERTY LINE. 7' IS PROV7 ED. A 3' VARIANCE IS REQUESTED TO SAVE THE /2' CALIPER OAK TREE. L OCUS -MAP 0 10 20 40 JOB NO: 03-027 FIELD:CFW/EEK CALC: SAH CHECK: CFW DRN: SAH h q _ i ... i..+.... .. 1 .. 'gip'