HomeMy WebLinkAbout190 River Street - Site Plan1 � I b I SYSTEM PROFILE TOP FNDN. ATI, EL: 1 1.7'ACCESSNOT TO SCALE) COVER TO WITHIN 6" OF FIN. GRADE � /- ACCESS COVER (WATERTIGHT) TO l,j 11.1' MINIMUM .75' OF COVER OVER PRECAST �! WITHIN 6" OF FIN GRADE - I RUN PIPE LEVEL �^^ .FOR FIRST 2' ' PROPOSED 1 5V VV I L 2, GALLON SEPTIC 6 87' 9 'TANK (H-,.Jv J GAS & g•49' BAFFLE 8.66' �� (� % SLOPE) 6" CRUSHED STONE OR MECHANICAL I. i. ... COMPACTION. (15,221 [2]) i DEPTH OF FLOW `)�. (-!-% SLOPE) (-L-7 SLOPE) °TEE SIZES: • , • - I. I INLET DEPTH 10" I. 'OUTLET DEPTH = 14" FOUNDATION -I :;l l' - SEPTIC TANK 21' NOTE: FLOODZONE FOUNDATION DESIGN BY OTHERS. , FINAL GRADING AROUND FOUNDATION TO BE IN ACCORDANCE WITH FEMA FLOODZONE STANDARDS. - EXISTING SAS CONSISTING OF 3 FLO DIFFUSORS PER AS BUILT CARD AT BOH EXIST. IS IN AREA OF PROPOSED PAVED SYSTEM . � .., DRIVE K8.38,3 125.90' p 8. ToFF4FF R yF I +I-B;e - - - - - - e.i C�TH- - - o 10.5'-_ ,tig. 1 RESERV - I m 8 B'f (765 8.3 ` I a 33.25' 33.25' .-- - ----- 8.5 1 8 8.3 I O O ESXIST. S I ,., I .1 8.1 / I 1 .NII YIYi. ® 1- i C I, 10 10YR 3/2 A/E LS I� w Bw �I 32" 1OYR 4/6 5.43 ' :RG19 Cl MCS , 72" OBS WATER 2.1' x 14" C2 I Ir 2.5Y 5/3 100" I 0.23' 3 7_ 1 I 1 16" 8.21 L=40.78' R=25.00' I I 05-44 7 I�ZnI,� 'n'•�4 22" oylo =<1A 0 s uI rq m FYI 0 r � t7 8.7 DECK 22" OAK OLT 88f u ae-X: F7 X- --+ 78 - - FT -8 RI VER STREET 30" D' BOX Lm Lm 22"ILOCUST � 0.58' 2% SLOPE REOUIRED OVER SYSTEM 2" DOUBLE WASHED 3/4" TO 1 1/2" DOUBLE WASHED STONE 3• LEACHING FACILITY 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND. PROVIDE APPROX. 103' OF 40 MIL LINER AT WESTERLY, NORTHERLY AND EASTERLY SIDES OF SAS, AT LIMIT OF REMOVAL, AS SHOWN. TOP AT ELEV. 8.9', BOTTOM AT ELEV. 4.9' 0 rn PROVIDE INSULATING .9•.ANKEf OVER EXIT SEWER LINE. FROM DWELLING TO PROPOSED SEPTIC TANK. 0 v- - PROP. DWELLING TOP FNDN = 11.7' BENCH MARK - CTR OF C.BASIN EL. = 7.8 •ii,l LJ I t1LJLt LLJhJ .I`I_(;II^.P' 13'I I'' PROVIDE INSPECTION PORT WITHIN 6" OF FINISH GRADEENGINEER: RICK JUDD, RS WITNESS: AMY VON HONE, RS DATE: 6/8/05 8.9' PERC. RATE < 2 MIN/INCH CLASS I SOILS �S 7,9' ELEV. „ 4 , 0 8.1 5' USE ADJ. WATER AT ELEV. 2.9' PI SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) DESIGN FLOW: 5_ BEDROOMS (110 GPD) = 550 GPD USE A J50 GPC DESIGN FLo SEPTIC TANK: 550 GPD ( 2 ) = 1100 USE A 1500 GALLON SEPTIC TANK LEACHING: SIDES: 2(33.25 +10.83)(.58)(,74)]2 = 75 BOTTOM: 2(33.25 x 10.83) (.74) = 532 TOTAL: 821 S.F. 607 GPD USE (10) STANDARD INFILTRATORS IN CONFIGURATION SHOWN, WITH 4' STONE AT SIDES AND 1' AT ENDS LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR - 100 EXISTING CONTOUR BOARD OF HEALTH APPROVED DATE off 508-362-4541 fax 508 362-9880 down cape engineering, inc, CIVIL ENGINEERS LAND SURVEYORS 939 main st, yarmouth, ma. 02675 MA I i a 5o BASS RN£R PARKWAY LOCUS it RIVER ST. [-LOCATION MAP nts ASSESSORS MAP 34 PARCEL 288 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' FLOOD ZONE: All ELEV, 11 GROUNDWATER ADJUSTMENT DATA WELL: MIW 29 ZONE: A ADJ: 0.8' - NOTES: 1. DATUM IS NGVD 2. MUNICIPAL WATER :S AVAILABLE 3. MINIMUM PIPE PI11H TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO EE MADE WATERTIGHT, 6. CONSTRUCTION DETAILS TO -BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. PUMP & REMOVE EXISTING SEPTIC SYSTEM TITLE 5 SITE PLAN OF 190 RIVER STREET IN THE TOWN OF: (SOUTH) YARMOUTH PREPARED FOR: WINDSWEPT HOMES 20 0 20 40 60 SCALE: 1" = 20' DATE: SEPTEMBER 27, 2005 ARNE H. OJALA, P.E., P.L.S. /o /Z D r DATE 01% 0 AID SL 10 10YR 3/2 A/E LS 15" 1OYR 4/1 Bw LMS 32" 1OYR 4/6 5.43 ' :RG19 Cl MCS 72" OBS WATER 2.1' 82" 2.5Y 6/4 C2 VFS 2.5Y 5/3 100" 0.23' SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) DESIGN FLOW: 5_ BEDROOMS (110 GPD) = 550 GPD USE A J50 GPC DESIGN FLo SEPTIC TANK: 550 GPD ( 2 ) = 1100 USE A 1500 GALLON SEPTIC TANK LEACHING: SIDES: 2(33.25 +10.83)(.58)(,74)]2 = 75 BOTTOM: 2(33.25 x 10.83) (.74) = 532 TOTAL: 821 S.F. 607 GPD USE (10) STANDARD INFILTRATORS IN CONFIGURATION SHOWN, WITH 4' STONE AT SIDES AND 1' AT ENDS LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR - 100 EXISTING CONTOUR BOARD OF HEALTH APPROVED DATE off 508-362-4541 fax 508 362-9880 down cape engineering, inc, CIVIL ENGINEERS LAND SURVEYORS 939 main st, yarmouth, ma. 02675 MA I i a 5o BASS RN£R PARKWAY LOCUS it RIVER ST. [-LOCATION MAP nts ASSESSORS MAP 34 PARCEL 288 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' FLOOD ZONE: All ELEV, 11 GROUNDWATER ADJUSTMENT DATA WELL: MIW 29 ZONE: A ADJ: 0.8' - NOTES: 1. DATUM IS NGVD 2. MUNICIPAL WATER :S AVAILABLE 3. MINIMUM PIPE PI11H TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO EE MADE WATERTIGHT, 6. CONSTRUCTION DETAILS TO -BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. PUMP & REMOVE EXISTING SEPTIC SYSTEM TITLE 5 SITE PLAN OF 190 RIVER STREET IN THE TOWN OF: (SOUTH) YARMOUTH PREPARED FOR: WINDSWEPT HOMES 20 0 20 40 60 SCALE: 1" = 20' DATE: SEPTEMBER 27, 2005 ARNE H. OJALA, P.E., P.L.S. /o /Z D r DATE 01% 0