HomeMy WebLinkAbout32 Sachem Path - Septic Design 5BM1<CHMM Tq.P OF FOUNDATION ELEV. = 100.00 4(ASSUMED) 20' PLUMBING TO BE RAISED AND RE -PIPED BY LICENSED PLUMBER AS NEEDED D�� 20 4' SCHEDULE 40 PVC PIPE FT. MINIMUM FROM CELLAR MIN. PITCH 1/8" PER FT. CLEAN SAND 2' LAYER OF 1/8" TO 1/2' FT. MINIMUM 10 FT. MLCONCRETE SLAB OR CRAWL SPACE 10 A 2" PRESSURE PIPE 150 PSI MINIMUM ELEV. = 10143 M WASHED STONE VENT NO UNSUITABLE 1 66.25 X 99.43 MIN. NO ELEV. 95.851 50" Cl RDElUM SAND 10YR7/6 NO 3' MAX. i 1CUFT. OF SAND CONCRETE _" ..... AN EL 98.43 T PUMP SWITCHES DETAIL 4' CAST IRON PIPE -- (OR OTCH EQUAL) PER FTM 2'0" ° MN o e L 1 L ELEV. = 6" SU P ELEV. 98 30 _ ° low ELEV. = 97_10 FLOW LINE -g8�- ELEV. = 93.67 ALARM ON ELEV. 98.33 10 DISTRIBUTION ELEV. = 4 HIGH CAPACITY INFILTRATORS 1T� 7MIN. GAS - 3/8" DRILL BOX ---�- WITH STONE IN AN z < V. = 93.42 PUMP ON ELEV. = 98.75 BAFFLE HOLE TO BE WATER TESTED 11' X 36' X le TRENCH FORMATION WELL MIW29 14' ELEV. 96.50_ y (TO BE PLACED ON FIRM BASE) ZONE- A ELEV. _ CHECK 3/4" TO 1 1/2' SOIL ABSORPTION INDEX 9.6 ELEV. =93.08 PUMP OFF o ADJUST 2.81 2 10°' OUTLET2�5 VALVE WASHED STONE SYSTEM (SAS) TFF TO E PLACED ON FIRM E) 1.3 SOIL TEST DATE OF SOIL TEST 33/27L? SOIL TEST DONE BY _CRAIG R. SHORT, P.E. WITNESSED BY _U-NI-M-MEFN OBSERVATION HOLE 1 ELEV.=-98.8 PERCOLATION RATE -K --Z- MIN./INCH AT 52_64 INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 6° A LOAMY SAND f0YR5/2 NO UNSUITABLE 1 LFlOAMYT�SAND t0YR5/8 NO ELEV. 95.851 50" Cl RDElUM SAND 10YR7/6 NO SAND M. C2 do GRAVEL 10YR8/6 NO OB' C3 FINE SAND t0YR8/4 NO 19 INCHES ( 500 GALL 19 INCHES L MYERS MHV 4 OR 5 mVARIANCE WATER ENCOUNTERED AT ,6-8 ELEV. _ X1-8 24 INCHES UMP (OR EQUAL) USGS PROBABLE WATER TABLE ELEV. 93.1 34 INCHES SEPTIC TANK CHAMBER OBSERVED WATER TABLE (03 / 27 /02 ) ELEV. 91X_ (94.4 MAX.) 1000 GALLON BOTTOM OF TEST HOLE ELEV. _ . PUMP CHAMBER CALCULATIONS: LEGEND: DESIGN CALCULATIONS SEPTIC TANK EXISTING SPOT ELEVATION 00,0 NUMBER OF BEDROOMS 3 REQUIRED FLOW PER CYCLE 25 X --33Q - --OM GAL./CYCLE EXISTING CONTOUR ----00---- GARBAGE DISPOSAL UNIT _ NO ELEV AT INVERT INLET VOLUME 93_87 VOLUME OFRWATEREtN PIPE 3G14L XCO 0069YCLE 4 XB G25 /C FTU. . T _Q55�Cu FT.U. CYCLE FINAL SPOT FINAL CONTOUR NATION 0. TOTAL0 GAL-/BR./DAY X I_ SR.) ESTIMATED FLOW SEWAGE DISPOSALSYSTEM PROFILE ELEV. AT ALARM N 93.42_ - SOIL TEST LOCATION 9 REQUIRED SEPTIC TANK CAPACITY �3Q GAL. NOT T SCALE ELEV. AT PUMP ON TQTAL MINIMUM VOLUME PER CYCLE , _ 1]„'�8 CU. FT, ELEV. AT PUMP OFF 938_ UTILITY POLE -0 BOTTOM OF INSIDE PUMP CHAMBER DISCHARGE _TACIT CU. 0 / 34.67 Y /7./FT. _ _ OFT. FT. (CU.F G.S.T.) ACTUAL SIZE OF SEPTIC TANK _15W GAL. 92,25_ STORAGE CAPACITY (_„e'iSL_ GAL./DAY /7.48 GAL./CU.FT./34.67 CU.FT./FT. _ ��27_ FT. TOWN WATER -W-.�W BOTTOM OF OUTSIDE PUMP CHAMBER 92.00 CATCH BASIN /®� SOIL CLASSIFICATION -iaL REQUIRED 2.56 PROVIDED \_/ DESIGN PERCOLATION RATE <_ MIN./IN. GAS LINE EFFLUENT LOADING RATE _Q,j4 GAL./DAY/S.F. CLEAN OUT C� LEACHING AREA 474 SQ. FT. CESSPOOL C.P. Q 111(28.5'+9.5' +(28.5'+20.5')2(10/12) LEACHING CAPACITY (AREA X RATE) 351 GAL -/DAY 0.74 BUOYANCY CALCULATIONS: x RESERVE L LEACHHINGIND CAPACITY �! A GAL./DAY 15WGALLON SEPTIC TANKH2O 1000 GALLON PUMP CHAMBERR10 WEIGHT OF WATER DISPLACED WEIGHT OF WATER DISPLACED NOTES: (94-92.25X10.5X5.67)(64LBS/CF)m BASS LBS. (94-92)(8.5x4.83X84) 5255 LBS. 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. WEIGHT OF TANK PER MANUFACTURER 11,480 WEIGHT OF TANK PER MANUFACTURER 8240 TITLE 5 AND THE TOWN RULES AND REGULATIONS FOR THE SUBSURFACE EXCESS WEIGHT TO OFFSET FLOTATION 4,812 EXCESS WEIGHT TO OFFSET FLOTATION 2985 DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO I' WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. VEN TM �p� /� 4. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE SHALL 10 1n� `I IV� "�'H' V/F USGS FOR �� BE MORTARED IN PLACE. SECTION 15.103 (3}(B} USE OF USGS-FOR MAX. _--A _ - N S. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH SEE GROUNDWATER. 2.6 REQUIRED 265 -1 A 1.3' VARIANCE REQUESTED. DEEDED OR ZONING REGULATIONS. OWNER /APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. SECTION 15212(8) DISTANCE BETWEEN BOTTOM 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR �No OF S.A.S. k GROUND WATER 5' REQUIRED. IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS A 1.0' VARIANCE REQUESTED. PRIOR TO COMMENCING WORK ON SITE. sN 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS __5 1 SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION y LOT 54 , IS TO BE BROUGHT TO THE _ OF THE DESIGN ENGINEER �1Qtoo* &,f. IST PUMP IMMEDIATELY. BOX CHAMBER \8. PARCEL IS 1N FLOOD Z E 9. LOT IS SHOWN ON ASS SOBS MAP _ 23 AS PARCEL 10. ALL UNSUITABLE MA AL SH BE REMOVED FROM UNDER, AND 1 Md 0 FOR A MINIMUM OF 5 AROUND THE SOIL ABSORPTION SYSTEM, CED 1 SEPT AND BE REPLACED WITH SAND AS SPECIFIED IN 310 CMR 5 .255: (3) g „ (LE. TITLE 5) IF ENCOUNTERED BELOW S.A.S. PIPE INVERT. TANK !h N y � % 11, EXISTING SEPTIC SYSTEM TO BE PUMPED AND FILLED WITH SAND a; it .I J\* OR REMOVED. 12. SEPTIC TANK k PUMP CHAMBER TO BE WATER PROOF BY MFR (IPX). ° f.17S1JNG �PR���{{ 29 W DWFZLNJG !0'utD g SHORT AGE 7 z'�� NCIVIL 9 �u (- � � APPROVED: BOARD OF HEALTH 0. i f9�Gr�TEk�' �; 1 �'tuxxrce°`�`E`.•. N w 15�NG BE ✓ �lbN1 4 EX 10 #2287 DATE AGENT PROPOSED SEPTIC DESIGN 0, �s _ -1J S "�' 2 r r f, FOR JAMES MORSE = B/T-ASPHAL T DR/VF' P i Loc. 32 SACHEM PATH -Y- �- �,' ",_SA��Eµ TIEST YARMOUTH, MASS r, CR rG R SHORT, P.R L - h/ 235 P EAT BOX E 4 ROAD 508- 398-8311 SOUTH DENNIS, MASS. 02660 4F N/'S. 'Y � pp"D '�• � DAT APRfL 11, 2002 SCALE 1." = 20' 1' �! REVISED JOB NO - 12 -943 LOCATION MAP REVSED SHEET 1 OF 1 0 2002 CRAIG R.