HomeMy WebLinkAbout19 Sagamore Road - Sewage Disposal System Design 2SOIL TEST PIT DATA: SEPTEMBER 10, 2002 TEST PIT -#j- GRD. EL. 10.4 EST. HIGH GW. 3.0 INDICATES A LOAMY SAND 10YR 4/3 LOAMY6 SAND 10YR 5/4 EL = 8.8 MEDIUMI SAND 10YR 5/6 LOAMY FINE SAND 2.5Y 5/4 EL = 3.6 EL = 3.0 EL 0.9' - LOAMY FINE SAND 2.5Y 6/3 6" 19" 67" 81" 88" 114" ESTIMATED SEASONAL HIGH GROUND WATER INDICATES V_ OBSERVED GROUND WATER INDICATES PERC. TEST �j INDICATES u UNSUITABLE MATERIAL DATE: 9/10/02 TEST BY- THE BSC GROUP, INC. WITNESSED BY: LYNN MULKEEN-MCCARTIN PERC. RATE: 6 MIN./INCH SOIL EVALUATOR CRAIG FIELD SOIL CLASS: 1 EL = 0.4 120" \ DOMENICK J. ROSSETTI ASSESSORS MAP 29 L. T.A.R. 1. THIS PLAN IS FOR DESIGN AND PLAN 0.74 G.P.D./SQ.FT. SCALE: 1' = 10 FEET 0 5 10 DATUM: 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE VERTICAL DATUM: 1929 NGVD 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE BENCH MARK USED: TOWN OF YARMOUTH MONUMENT #4 BENCH MARK SET: TOP OF CONCRETE BOUND EL.=10.59 PROFILE: NOT TO SCALE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL. EL= A OR OTHER CLEAN GRANULAR SOILS CONFORMING TO THE FOLLOWING TOP FOUNDATION 10% (MAX) BY WT. SHALL FIRST PIPE LENGTH BOLT ON METAL COVERS TO PASS No. 100 TO BE SET LEVEL FINISHED GRADE. UNIFORMITY COEFFICIENT 0 No. 4 FOR MIN. 2' 7. EXISTING UTILITIES WHERE SHOWN /E�L-11.5 THE CONTRACTOR SHALL BE RESPON- FINISH GRADE. COORDINATING THE PROPOSED CON- :! AND THE APPLICABLE UTILITY EL9.6-9.7 EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS 4" PVC SCH 80 AT TEL 1-888-344-7233. THE rf THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND j"` TAKEN FROM RECORD PLANS. THE 4" PVC SCH 8 LOCATION AND INVERTS OF UTILITIES LEACHING FIELD 28'00. 8 THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. 4'®0.03 -D onanonannnonannnnng ADVERSE IMPACTS TO THE LEACHING FACILITY. I THE CONTRACTOR PRIOR TO CONSTRUCTION 1=G C REQUIRED. I -E 349 Route 28, Unit D W. Yarmouth Massachusetts 02673 508 778 8919 PROJECT TITLE: 5 OUTLET 1=F REPAIR #19 DIST. SEPTIC TANK BOX 5' SEPARATION PROVIDED PREPARED FOR: ROBERT BARTOLINI 35 WOODLAND ROAD IEST. HIGH �OUNDWATER (508) 561-7400 DATE: SEPTEMBER 25, 2002 K INVERT ELEVATIONS: DRAWN: K. HEALY I TOP OF FOUNDATION 12.3 A GARAGE SLAB 9.80 4" INVERT AT BUILDING 9.70 B 4" INVERT AT SEPTIC TANK (IN) 9.30 C 4" INVERT AT SEPTIC TANK (OUT) 9.05 D 4" INVERT AT DIST. BOX (IN) 8.90 E 4" INVERT AT DIST. BOX (OUT) 8.73 F INVERTS AT LEACHING FACILITY: 4". INVERT AT BEGINNING OF LEACHING FIELD 8.66 G 4" INVERT AT END OF LEACHING FIELD 8.5 H ELEVATION AT BOTTOM OF LEACHING FIELD 8.0 J ADJUSTED FOR HIGH TIDE 3.0 K OBSERVED GROUNDWATER 0.9 VARIANCES REQUESTED: TITLE V. SECTION 15.211: (1) TO ALLOW LEACHING SYSTEM TO BE 5' OFF FRONT PROPERTY LINES IN LIEU OF 10'. SEPTIC TANK DETAIL: 1,500 GALLON H-20 DISTRIBUTION BOX DETAIL: H-20 LEACHING FIELD DETAIL: NOT TO SCALE NOT TO SCALE NOT TO SCALE NO. OF OUTLETS 9 VENT NOTES: 1. SEPTIC TANK SHALL BE STEEL 5. INLET AND OUTLET TEES TO BE CAST IRON, FINISHED GRADE 36" MAX .COVER REINFORCED CONCRETE. SCHED. 40 PVC OR CAST -IN-PLACE CONCRETE 2. SEPTIC TANK TO WITHS ND H-10 LOADING TEES TO BE CENTERED UNDER MANHOLE COVER. + .,; REMOVABLE a• a••+.o:•o.. 3 UNLESS UNDER PAVEMENT, DRIVES OR COVER "' i _ � WALLS NOTES: � FINISHED GRADE 3.0• TRAVELED WAYS, WHEREN H-20 LOADING SHALL APPLY. rg,5- a.:: ' 5" 1. DIST. BOX TO WITHSTAND H-20 LOADING 3. ALL PIPE CONNECTIONS AND CONCRETE 2. PROVIDE INLET TEE OR BAFFLE WHERE CONSTRUCTION SHALL B WATERTIGHT. 2-24" DIA CONCRETE MANHOLES T T SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR 4" PVC-' ' • • �-• W/ METAL HANDLES BROUGHT 4. FILL ALL UNUSED KN OUTS WITH W 6" OF FINISH GRADE 20" IN PUMPED SYSTEM. eae e a e a e 4' PERF SCH 90 PVC S=0.005'/• q� / a v cu TE °9f��,e meq,° gP�a>f�� ��°• ���°• ° rte° a"""'4o i� r. MOTH MORTAR. 3. FIRST TWO FEET OF PIPE OUT OF DIST. �' � 'f 4' A' $" /e ea eae a et ea eaeae eae ea eae ea84 e e TEE TO BE UNDER 6" OUTLETS a BOX TO BE LAID LEVEL- M.H. °4P°°de 12" MIN. OPENING COVER ....+• •. •. � ! 6• �a rP° e e ee a ee a sea ee+ T 4. RECOMMENDED MANUFACTURER-ROTONDO LEVEL BOTTOM RAISE M.H W,L r 6" n�� �� �� � �'4 L_ 4" OR APPROVED EQUAL F 32' BOTTOM ON LEVEL SEWER BRICK e- - - STABLE BASE 6" MIN_. 3 4" TO 5. ALL PIPE CONNECTIONS AND CONCRETE & MORTAR `" '' PROFILE 10'-0" 12" CROSS-SECTION 1 1/2 CRUSHED CONSTRUCTION SHALL BE WATERTIGHT. NORMAL WATER LEVEL STONE BASE 6 FIT BREAKOUT BARRIER SNUG AROUND M � 3" PRECAST SEPTIC TANK 10" 14' T O C T e INLET TEE :g 5'_p^ 4'-1:DE tMr solo ON 6'-2" LIQUIDH (GAS CONN say a- TEE 30" 1 _N :t 'e - e: F.:.•�e:'..:: " a BOTTOM ON LEVEL STABLE BASE 9tc D -BOX AND USE EPDXY RESIN FOR WATER 36" MAX. - 12" MIN. COVER TIGHT SEAL 2% MIN. FINISH GRADE 4" MIN. LOAM do SEED 7. FILL ALL UNUSED KNOCKOUTS HATH MORTAR. / LOAM do SEED DISTURBED AREAS 34 MAXIMUM 15' MN 6' g44 4', e eae a`9 ae e a L2" MIN. OF 1/8" TO a°`hP L� 1/2" WASHED STONE i�d to e a e4eya' ea s 3po�° e e PLAN VIEW �� 3/4" TO 1-1/2" // ` L8^ WASHED STONE (NO FINES) L-1,5' 4' 1 (4) 1 4' 1 1.5' 1 6• MIN. 3/4" To Fr4"4 � CROSS-SECTION VIEW ��� � r A I �- �� 'T 1 1/2" STONE PLAN VIEW CROSS-SECTION CB/LEADED DESIGN CRITERIA: o DESIGN FLOW 0 0 3 BEDROOMS AT110G.P.B./D 330 G.P.D. S• (� N N REQUIRED SEPTIC TANK - BENCHMARK: o l� ' \ N N 330 X 200% = 660 GAL. p \ r ITANK PROVIDED: = G TOP OF CONC. SEPTIC 100 AL. FFA � r 5 BOUND EL 10.59 o - N.G.V.D. � ^ N CONCTRACTOR TO BE CPLAD UG \ /� \ HIGH POINT IN AWARE OF OHWD-BOX / ROAD. ELEV d N/F (OVERHEAD WIRE) at1 X 10.6 ti \ 10.8 NGVD MICHAEL KACZMAREK Ar, FQ ASSESSORS MAP 29 PROPOSED H-20 "0' , Y PARCEL 127 1,500 GALLON MIN Ooe O O \ o SEPTIC TANK /y 1 \ " 0 0 A q CONCTRACTOR T N/F PAUL D. GOODRICH ASSESSORS MAP 29 PARCEL 118 SIZE OF LEACHING FACILITY REQUIRED: DESIGN PERC. RATE: <6 MIN./ INCH LONG TERM APPL. RATE 0,70 G.P.D/S.F. 330 GPD _ 0,70 GPD/SF = 472 S.F. to HW / F \ / \ OBE I - o�'� � OAWARE of WHw SIZE OF LEACHING FACILITY PROVIDED: EXCAVATION 0LIMITS OF0 TEST PITF\tip \ (OVERHEAD WIRE) SEE NOTES O� / 5 AND 6HW \ 330 GPD _ 0,70 SF/GPD = 472 S.F. REMOVE & REPLACE S - EXISTING WATER S / / 9 9S, Pss9 \ USE: LEACHING FIELD LINE SS 0 + I N/F RONALD C. YATES LI E EST. ASSESSORS MAP 9 PARCEL 119 C� 5. UPLT BOTTOM 15' x 32' = 480 S,F 480 S.F X 0,70 GPD/SF = 336 GPD GF, C.O. / \ 12" -OAK- . ' /v 10 ti c6/LEAD \ LOCUS INFORMATION • 5 P jc, �9Blq /POP `s e MI o T ro PLUG \ \ &'CB CURRENT OWNER: LAUREL MILLS N/F / ^/ / U \/Q \ 0/ \ TITLE REFERENCE: DEED BOOK 16017, PAGE 325 19 J LAUREL MILLS / / < EXISTING 3 BEDROOM \ / g�. \ \ 0• $ \ PLAN REFERENCE: BOOK 33, PAGE 63 ASSESSORS MAP 29 \ DWELLING TO BE / °F. PARCEL 126 q \ REMOVED & REPLACED / P O F \ \ ASSESSORS MAP: 29 5,400±S.F. / \ pp \ / G� �P MIN J \ WITH A NEW // O PARCEL: 126 \ >.0 �p \ 3 BEDROOM DWELLING / �O �P CB \ \ - FO PROP. TOF 12.3 i / ONO PCS° ZONING DISTRICT. R-25 EXISTING \\r'�,�F \ // �� c�� \ SETBACKS: FRONT 30' LEACHING AREA \ Of \ / QO \SIDE REAR 20', TO BE LOCATED AND \ \\ // SO• ABANDONED IN \ \ / 0 / O \ MINIMUM LOT SIZE: 25,000 S.F. O•. ACCORDANCE WITH F TITLE V r \ EXIST. TOTAL LOT AREA: 5,400 S.F. �� ��`� 00 0 0 0 O \ OVERLAY DISTRICT: NOT IN A ZONE II .s �P�� 6 • NO O g 0� Z m \ FEMA FLOOD �- v \ ZONE DISTRICT: ZONE A-12 (ELEVA 0��, PANEL #250015 0005 FyOF ti0 ( OSP OF, 6.2 PROP. LOT COVERAGE (DWELLING & DECK) 1,131± S.. (21q) CRAIGA 00gbh N/F Na 36039 O b 00• Op9� FRANCES RAND -SHAW ASSESSORS MAP 29 to LOCUS PLAN: NO SCALE PARCEL 125 28 ,7.7 A-4, tn: pFMg�L4/O o° N e$/ uN G. \SFr N/F \ DOMENICK J. ROSSETTI ASSESSORS MAP 29 PARCEL 120 1. THIS PLAN IS FOR DESIGN AND PLAN VIEW SCALE: 1' = 10 FEET 0 5 10 20 FT. �•' _rtnit valid for REPAIR OF SEPTIC S STEM ONLY, due to State and Local septic va antes. r"rd of Health review and approval Is re. nired for any future additions/renovations/alteratI is to sewage facilities and/or structures/dwelling. Yarmouth Health Department ,YV"SAPPROVE+ D [Y me Date LOCUS t RO R0. SrMfr FILE COPY REVISIONS NO. DATE DESCRIPTION 1. 4/29/08 NEW DWELLING RELOCATE TANK H-20 COMP. GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY do NEW DWELLING LOCATION ONLY 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL. 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL. 6. REPLACE WITH CLEAN WASHED SAND OR OTHER CLEAN GRANULAR SOILS CONFORMING TO THE FOLLOWING SIEVE ANALYSIS: 10% (MAX) BY WT. SHALL PASS No. 50 SIEVE <10 % OF No. 4 SIEVE SHALL PASS No. 100 <5 % OF No. 4 SIEVE SHALL PASS No. 200 UNIFORMITY COEFFICIENT 0 No. 4 SIEVE </=6.0 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO THE START OF CONSTRUCTION. 8 THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING FACILITY. 9. EXITING INVERTS ARE TO BE CHECKED BY THE CONTRACTOR PRIOR TO CONSTRUCTION THE ENGINEER IS TO BE NOTIFIED OF ANY FIELD CHANGES THAT MAY BE REQUIRED. 11i'tsJ',�rEl 349 Route 28, Unit D W. Yarmouth Massachusetts 02673 508 778 8919 PROJECT TITLE: SEWAGE DISPOSAL SYSTEM DESIGN REPAIR #19 SAGAMORE ROAD W. YARMOUTH MASSACHUSETTS PREPARED FOR: ROBERT BARTOLINI 35 WOODLAND ROAD ASHLAND, MA 01721 (508) 561-7400 DATE: SEPTEMBER 25, 2002 COMP. DESIGN: K. HEALY CHECK: B. YERGATIAN DRAWN: K. HEALY FIELD: D. GAZZOLO / J. MCCARTIN FILE NO. 8448-SEP.DWG DWG NO. 5320-04 SHEET 1 OF 1 JOB N0.4-8448.00 FIDE COFY