4" EXP. JOINT
AROUND COL.
FIN. FLOOR
wQ
W J
o.
wQ
N J
a-
SEE TYPICAL DETAIL
FOR REINF.
SEE PLAN
TYPICAL COLUMN P
SCALE:2„=1
SEE FNDN PLAN
FOR TOP OF CONC.
BEARING SURFACE ELEV.
F-
o. w
x
Q U
w
X
LJO
I- < n n:
a,
a� •ILII
•- .nr� aV
3"
CE COL.
_ SEE TYP COL. BASE
SETTING DETAIL
6x6 WWF (TYP)
w Z
ws
VAPOR BARRIER
COMPACTED
GRANULAR FILL
y" 0
ANCHOR BOLTS
DETAIL
CL COLUMN
BASE PLATE
(SHOP WELD TO COL)
4" LEVELING PLATE
TO MATCH SIZE OF
BASE PLATE
i" NON -SHRINK
GROUT MIN.
i" 0 xt'-3" ANCHOR BOLTS
(SEE TYPICAL DETAIL FOR
NUMBER OF BOLTS)
.TYPICALCOLUA4N BASE
SETTING D TAIL
SCALE: 4" =1'- "
STRUCTURAL NOTES
1. All structural work shall be coordinated with the
architectural design plans and shall conform to the
following governing standards:
A) The Massachusetts State Building Code, sixth
edition, and all other agencies having jurisdiction.
B) ACI "Building Code Requirements for Reinforced
Concrete." (ACI 318-02)
C) The Code for Welding in Building Construction by the
American Welding Society (AWS D1.1)
D) AISI Specification for the design of Cold Formed
Steel Structural Members.
E) The Timber Construction Manual, 4th edition,
American Institute of Timber Construction.
F) The National Design Specification for Wood
Construction, latest edition.
2. All construction is to conform to the Massachusetts
State Building Code and all applicable product and design
standards. Absence of specific items from these drawings
does not infer that the Contractor is relieved from the
statutory code requirements.
3. All materials and methods of construction shall conform
to the approved rules and standards for materials, tests,
and requirements of accepted engineering practice as
listed in Appendix A of the Massachusetts State Building
Code.
4. The Contractor shall verify all dimensions and conditions
in the field prior to commencing work. Any discrepancy
between what is shown on the drawing and actual field
conditions shall be reported back to the engineer before
proceeding with any work.
5. Design Vertical Live Loads:
Attic Floor Load - 20 psf
Floor Load (Sleeping Rooms) - 30 psf
First Floor Load (Not Sleeping Rooms) - 40 psf
Exterior Deck Load - 60 psf
Snow Load - 25 psf
6. Design Lateral Loads:
- Wind Load:
Zone - 3; Exposure - C
Reference Wind Pressure - 21 psf
FOUNDATIONS
1. Assume maximum safe soil bearing pressure - 4,000
psf.
2. All footings are to be placed on natural undisturbed
material or compacted granular fill. Subsoil bearing strata
shall be free from all vegetation, loam and organic
material.
3. All footings shall be placed on a 4" layer of crushed
stone compacted to 95% Standard Proctor Density.
4. Slabs on grade shall bear on natural undisturbed soil or
on controlled compacted fill. Remove existing fill material
where necessary and replace with clean granular fill
compacted in 6"-8" layers to obtain 95% standard proctor
density at the optimum moisture content.
CONCRETE
1. Concrete mixture, form -work, delivery and placement
shall conform to all requirements of ACI 301 (latest
edition), unless otherwise noted.
2. Concrete materials shall be: Type 1 or 2 Portland
cement, sand and gravel aggregates. Concrete shall be
air -entrained per ACI recommendations. Concrete
compressive strength, (f'c) in 28 days, when tested in
accordance with ACI 318-02, shall be as follows:
All concrete work - 4,000 psi
3. All mixing, transporting, placing and curing of concrete
shall be done in accordance with the recommendations c:
the American Concrete Institute,
4. Reinforcing steel shall be deformed bars conforming to
ASTM A615, grade 60, except where noted. No. 3 bars
may conform to ASTM A615, Grade 40. All reinforcing bars
welded to a steel section should be of welding grade 40.
5. Welded Wire Fabric (WWF) shall conform to ASTM A185
with a minimum tensile strength of 70,000 psi.
6. Reinforcing steel shall be placed to provide the following
minimum concrete cover (see section 7.7 ACI 318-02 for
conditions as noted):
Footings - 3"
Slab on Grade - 1" top
Grade Beam - 14" top, 3" bottom
Piers - 2"
7. Sill plate anchors to be ASTM A307 bolts embedded
into top of concrete foundation wall at maximum spacing
of 4' on center, unless noted otherwise. Anchors shall
have minimum embedment of 8" into concrete and shall
have 90' hook unless noted otherwise on plans.
B. Column anchor bolts are to be furnished and installed
according to design plan. All column anchor bolts shall be
set by template.
9. All continuous reinforcement shall hove Class "B"
splices (ACI 318-02, Section 12.15) unless noted otherwise.
10. All lap splices In WWF should be on mesh plus two
Inches.
FRAMING LUMBER
1. All framing lumber shall conform to the latest edition of
the NFPA "National Design Specification for Wood
Construction and supplement "Design Values for Wood
Construction", latest edition. Maximum moisture content
shall be 19X
2. All exposed wood members used for structural framing,
decking, stairs, rails, bracing, etc. shall be pressure treated
with ACO preservative, or approved equal, to minimum
detention of 0.6 PCF in accordance with AWPA C3.
3. The framing lumber shall be of the following minimum
grade and species for the specified use. All lumber shall be
grade stamped by a recognized grading agency and shall
be surface dry.
DIMENSIONAL LUMBER
For Exposed Pressure Treated Member
-floor joists & beams #2 Southern Yellow Pine
Fb = 975 psi, E = 1.44E6 psi
-timbers and posts #2 Southern Yellow Pine
(5x5 & larger) Fc = 525 psi, E = 1.2E6 psi
For Non -exposed Members**
-floor joists & beams #2 Spruce Pine Fir
Fb - 875 psi, E - 1.4176 psi
-studs #2 Spruce Pine Fir -
Fc = 1150 psi, E = 1.4E6 psi
-timbers and posts #2 Spruce Pine Fir
(5x5 & larger) Fc = 500 psi, E= 1.OE6 psi
(*Design values adjusted only by Cm)
(**Design values not adjusted)
4. Details of wood framing such as nailing, blocking,
bridging, firestapping, etc. shall conform to the latest
edition of the National Design Specification, and the Timber
Construction Manual
5. Stud bearing walls are to be 2x4 ® 16" o.c. at the
interior and 2x6 @ 16" o.c. at the exterior.
6. All metal hangers, connectors fasteners, etc. securing
ACO pressure treated lumber shall be triple Z -max
galvanized or stainless steel.
SPECIAL REQUIREMENTS FOR COASTAL CONSTRUCTION
1. Elevations shown are referenced to National Geodetic
Vertical Datum (NGVD). See site plan by Down Cape
Engineering Company for benchmark datum reference.
F -=v F= f_`_O^_15-O005 0
Tc+ of Yormouth
Flood Zone A.12 Elev. - 11.0"
2. Special provisions for Coastal Construction shall be In
accordance with the recommendations found in the "Coastal
Construction Manual" as published by the Federal
Emergency Management Agency (FEMA -55).
3. The building structure and components shall be
adequately anchored to the foundation to prevent
floatation, collapse, and/or lateral movement.
4. The entire building structure is to be tied together at
act as a continuous, integral unit using joist anchors,
metal ties down strops, well nailed plywood sheathing, bolts
through beams and piles, etc.
5. Galvanized metal joist anchors and tie sown straps shall
be as manufactured by Simpson Strong -Tie Co. or
approved equal and shall be installed at each roof rafter,
floor joist connection, and wall stud connection.
6. All steel members, connections, connectors, etc. shall be
hot dipped galvanized. All metal connectors must be
routinely inspected and maintained over the serviceable life
of the structure.
7. All holes, machine areas,' and cuts to lumber made in
the field shall be liberally brushed with a solution of copped
nopthenate containing a minimum of 2% metallic copper in
solution in accordance with the AWPA Standard M-4.
8. All items shall be rigidly anchored or attached, square,
plumb and true, or on other planes and shapes shown on
the drawings. Joints shall be tight, even and free of
offsets. All surfaces shall be sanded, filled or otherwise
prepared to receive finish where indicated.
0:1 IO2M11t91aliv!
O.F.
Outside Face (of bldg/masonry)
E.F.
Each Face
E. W.
Each Way
I.F.
Inside Face
T.O.C.
Top of Concrete
T.O.W.
Top of Concrete Well
T.O.P.
Top of Concrete Pier
T.O.F.
Top of Footing
T.O.GB.
Top of Grade Beam
T&B
Top and Bottom
E.E.
Each End
E.S.
Each Side
M.O.
Masonry Opening
STEEL
1. Structural steel rolled shapes shall conform
to the
following
ASTM
designations:
ASTM
A36
All steel base plates, angles,
channels
and misc. framing members,
unless
otherwise noted
ASTM
A307
All other anchor bolts unless
noted
otherwise
ASTM
A53
All round pipe sections
Gr. B
2. Grout used under column base plates should be ofthe
non -shrinkable variety with a minimum compressive
strength of 5000 psi in 28 days.
3. All welding shall conform to the standard of the
American Welding Society (A.W.S.).
4. Electrodes for all field and shop welding shall conform
to ASTM A233 (class 70). Allweldsnot shown shall be
AWS minimum.