HomeMy WebLinkAbout3 Sheffield Road - Septic DesignTOP OF FOUNDATION ELEV. = 100.80 --- SLAB SLAB ELEV. _ 0 4" CAST IRON PIPE (OR EQUAL) MINIMUM PITCH 1/4" PER fT. _EV. 92.35 ELEV. = 10 FLOW LINE 10" MOTT. _T MIN 0-7 O/E MEDIUM SAND 10YR7/1 NO BAFFLE 7-31 B LOAMY SAND 4" SCHEDULE 40 PVC PIPE MIN. PITCH 1/8" PER FT. ELEV. 91.87 LE' EL ELEV. = 91_30_ 6" SUMP ELEV. DISTRIBUTION ELEV. 80X (TO BE PLACED ON FIRM BASE) �L44_ TO BE WATER TESTED 1500 ALLON IF MORE THAN ONE OUTLET SEPTIC TANK (TO BE PLACED ON FIRM BASE) 3/4" TO 1 1/2" CLEAN DOUBLE WASHED STONE FREE OF FINES & SILT SEWAGE DISPOSAL SYSTEM PROFILE NOT TO SCALE (= 97.9 A I 1 r ,1 47.22" �r i 3 97.2 I \ LOT I \ 27,644.0 _-L- 0. 6 -L-0.6 t AC. Eir,vAI, am,»_ JWM' G•.1 94.5 CL EAN SAND CTION PORT LOAM AND SEED 2" LAYER OF 1/8" TO 1/2"WASHED STONEPNEONTTREQUIRED 92.25 MM. F9 e10'' ELEV. = 90.17 SOIL TEST DATE OF SOIL TEST DECEMBER 23, 2003 SOIL TEST DONE BY SWEET5ER ENGINEERING - WITNESSED BY B.MSLRPH-Y __ OBSERVATION HOLE I ELEV.= 94_00 OBSERVATION HOLE 2 ELEV.= 93.00 PERCOLATION RATE < 2__ MIN./INCH IN C HORIZON PERCOLATION RATE _ <_ MIN./INCH AT 68 INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-7 O/E MEDIUM SAND 10YR7/1 NO 7-31 B LOAMY SAND 10YR7/4 yf� p�f/t an}}r srim ENG iiL[YG 235 GREAT WESTERN ROAD 508- SOUTH ODENMS��MASS. 398-3922 02660 ' ROOTS 31-138 C MEDIUM SAND 2.5Y8/2 DATE JAN. 6, 2004' COBBLES 3 HIGH CAPACITY INFILTRATORS WITH STONE IN AN Z 11' X 24' X 10f TRENCH FORMATION •17 Lo WELL N A NO WATER ENCOUNTERED AT _ 739_ ELEV. = 82 5 . SOIL ABSORPTION 0 ZONE SYSTEM (SAS) INDEX ADJUST USGS PROBABLE WATER TABLE ELEV. = OBSERVED WATER TABLE ( / / ) ELEV. _ BOTTOM OF TEST HOLE ELEV. _ ROAD SHEFFI EL -- - -- - - - _02)_ _ ��� - A° 2233 I o I A al f � a I PORdH PROPOSED DONLIG Y 2 BEDROOMS = 96.6 -------------\ = 95.1 •.% 96.1 " 96.5 1500 G SEPTIC D. BOX SOIL TEST 2 / ReSER� SAS r " 9� 8 24.0a ___j;_ SOIL TEST 1 TANK 112.56' / / / / / / �9 97.0 / • 96.1 \ 113'01 \1 96.9 r -J ��- / / �• 102.3 - 91.4 LEGEND: EXISTING SPOT ELEVATION x0.0 EXISTING CONTOUR----00---- FINAL SPOT ELEVATION 00. FINAL CONTOUR n SOIL TEST LOCATION UTILITY POLE Ca� TOWN WATER -W W CATCH BASIN (ON GAS LINEG CESSPOOL CP CLEANOUT O. T. A. DUMAS KID. 819 DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-6 0/E MEDIUM SAND IOYR7/1 NO 6-46 B LOAMY SAND 10YR7/4 yf� p�f/t an}}r srim ENG iiL[YG 235 GREAT WESTERN ROAD 508- SOUTH ODENMS��MASS. 398-3922 02660 ' ROOTS & SCALE 1 �� = 20' DATE JAN. 6, 2004' COBBLES 46-132 C MEDIUM SAND 2.5Y8/2 REVISED NO WATER ENCOUNTERED AT No ELEV. _ __82.0-0. DESIGN CALCULATIONS NUMBER OF BEDROOMS _ 2_ GARBAGE DISPOSAL UNIT _�10 TOTAL ESTIMATED FLOW ( 110 GAL/W/UAY X _2_ BR.) _MQ_ GAL./DAY REQUIRED SEPTIC TANK CAPACITY _A4Q_ GAL ACTUAL SIZE OF SEPTIC TANK 1500 GAL SOIL CLASSIFICATION DESIGN PERCOLATION RATE <5_ MIN./A. EFFLUENT LOADING RATE -DJA_ GAL./DAY/S.F. LEACHING AREA 32233 SQ. FT. (11X24)+(35X2X10/12) LEACHING CAPACITY (AREA X RATE) MW2 GAL/DAY 32233 X 0.74 RESERVE LEACHING CAPACITY 238,52 GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2, ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. I 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS, 4. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS-BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO i OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE. APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-688-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7, CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. 8. PARCEL IS IN FLOOD ZONE C 9. LOT IS SHOWN ON ASSESSORS MAP 78 AS PARCEL 199 10. A NEGATIVE GRADE OF 3/4" PER FOOT SHALL BE MAINTAINED FOR A MINIMUM OF 15' AWAY FROM THE FOUNDATION. 11. A VARIANCE OF 2' IS REQUIRED FOR THE TOP OF FOUNDATION TO BE EVEN WITH THE HIGH POINT IN ROAD IN STEAD OF 2' ABOVE. 12. A DEED RESTRICTION LIMITING THE SITE TO TWO BEDROOMS IS TO BE RECORDED AT THE REGISTRY OF DEEDS. PARCEL IS IN A ZONE 11. APPROVED: BOARD OF HEALTH DATE AGENT Cr kS8kPR044635-00l,dwg>4635-SAS.DWC 02004 SWEETSER ENGINEERING OLD TOWNHOUSE o CON I=- � } = 3 u (,r - SHEFFIELD \\ LOCA Val PROPOSED SEPTIC DESIGN FOR DUBLIN CONSTRUCTION PROJECT PROJECT LOCATION IDT 1 J.1\J 3 SHEFFIELD RD., 17. YARMOUTH yf� p�f/t an}}r srim ENG iiL[YG 235 GREAT WESTERN ROAD 508- SOUTH ODENMS��MASS. 398-3922 02660 ' SCALE 1 �� = 20' DATE JAN. 6, 2004' JOB N0. ;4635-01 REVISED LOCATION N1AP REVISED SHEET `1 OF 1 Cr kS8kPR044635-00l,dwg>4635-SAS.DWC 02004 SWEETSER ENGINEERING