Loading...
HomeMy WebLinkAbout25 Shore Side Drive - Site Plan 3LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR — 100 — EXISTING CONTOUR 02-225 TOP FNDN AT E. 12.0' MIN S 1 .STEM PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) ACCESS COVER (WATERTIGHT) TO DESIGN FLOW: 4_ BEDROOMS (110 GPD) = 440 GPD I MINIMUM ,75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE USE A 440 GPD DESIGN FLOW 27, SLOPE REQUIRED OVER SYSTEM 9 75' s RUN PIPE LEVEL SEPTIC TANK: 440 GPD (2) = 880 9.60' FOR FIRST 2' 2" DOUBLE WASHED PEASTONE 0.75' min cover USE A ? 500 CALLON SEPTIC TANK PROPOSED 1500 9.1 15' GALLON SEPTIC 8.90' / 9.0' LEACHING: TANK (H— 10) / SIDES: 2(45 4 12). (•5E) (.74) = 48.9 BA T -- GAS 8 82' o000 8.65' 0 8.58' o BOTTOM: 45 x 12 (.74) = 399.6 ( % SL PE) \_6" CRUSHED STONE OR MECHANICAL $ 0'58 0 8 0, COMPACTION. (15.221 [2I) TOTAL: 606 S.F. 448.5 GPD DEPTH of FLOW = 4' ( 0 z SLOPE) � � % SLOPE) USE 45' x 12' LEACH FIELD OF 2 ROWS EACH OF 6 TEE SIZES: 10„ 3/4" TO 1 1/2" DOUBLE WASHED STONE STANDARD INFILTRATORS EACH, WITH 2' STONE AT SIDES, INLET DEPTH = 2.3' BETWEEN ROWS AND 3.75' AT ENDS OUTLET DEPTH 14" FOUNDATION— 22' SEPTIC TANK `.' D' BOX 9' LEACHING 5' FACILITY BOARD OF HEALTH _ —. MA APPROVED DAT: USE ADJUSTED WATER AT ELEV. 3.0' NOTE: DWELLING FOO ',NGS MUST BE MIN. 2' ABOVE (TIDALLY INFLUENCED) ADJUSTED GROUNDWi"TER ELEVATION (I.E. BASE OF FOOTING TO BE AT MINIMUM ELEVATION OF 5.0') FLOODZONE FOUNDATON DESIGN BY OTHERS PROP, ROCK RETAINING WALL, TOP AT EL. 9.0'. PROVIDE 40 MIL LINER ALONG INTERIOR OF WALL, TOP AT EL. 9.0', BOTTOM AT r EL. 5.0' + 7.4 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND. EXIST. DWELL. EXISTING !WELLING (HATCHED AREA) TO BE REED AND DEBRIS DISPOSED OF AT ANAPPROVED SITE EXIST. DWELL. � oRPSS 6EPGN 5iN EXIST, LANDING/STAIRS ir5.9 �F 9.8 cZ `NGF, .L�..s... � of ��Pr✓N C'R // i la P - EXIST. L< V9 EL.14 O TEST HOLE LOGS ENGINEER; TED DUMAS, RS WITNESS: COLLEEN PELLEY DATE: 4/24/99 PERC. RAl- _ < 2 MIN/INCH CLASS I SOILS P# 1. ELEV. 4 D,. 8.6' MUNICIPAL WATER IS AVAILABLE 25` MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H --1O 31' PIPE JOINTS TO BE MADE WATERTIGHT. 6, CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. 38" 5.4' FILL A LS 10YR 3/3 i 8 LS lOYR 4/6 C MS 84 OBS WATER 1,3 89" 2.5Y 7/3 v --I IJ v. I,, rnnr- 4v rHfC I.CL. I YL ZONING DISTRICT: R25 YARD SETBACKS: FRONT = 30' SIDE = 15' REAR = 20' PLAN REF. — LCP 21122A FLOOD ZONE: V15 EL. 16, V9 EL. 14 AND Ag EL. 10 (HOUSE IS 1N FLOODZONE A9 EL. 10) LOT COVERAGE: DECK AND DWELL. = 187 MS i 18" 10YR7/1 J, LS I 32" I 7.5YR 5/E" R, - 76 90" C MS l 2.5Y 6/6 OBS WATER _ 2,2' /V�:�3 DA "E ol! 508-582-4541 .ax 5C$ }67-9880 O'Own Cape engineering, Inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yci-mouth, r1n 02675 NOT -ES: 1. DATUM IS NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H --1O 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6, CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PIAN IS FCR PROPO`,17D WORK ONLY AND NOT TC uE 8. PIPE FOR SEPTIC SYSTEM 10 SCH. 4C-4" PVC, 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK, TEST HOL_ LOGS TITLE 5 SITE PLAN ENGINEER: AH OJALA, PE T OF 25 SHORE SIDE DRIVE DATE: 5/7/03 IN THE TOWN OF; PERC. RATE _ < 2 jaII,:H (SOUTH) YARMOUTH CLASS I SOILS _ PREPARED FOR; FRAN POLITO�� I 20 0 20 40 60 LEV. 0 " I SCALE: 1" = 20_ DATE: MAY 7, 2003 16 FILL `I MS i 18" 10YR7/1 J, LS I 32" I 7.5YR 5/E" R, - 76 90" C MS l 2.5Y 6/6 OBS WATER _ 2,2' /V�:�3 DA "E ol! 508-582-4541 .ax 5C$ }67-9880 O'Own Cape engineering, Inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yci-mouth, r1n 02675