Loading...
HomeMy WebLinkAbout25 Shore Side Drive - Site Plan 4SYSTEM PROFILE TEST HOLE LOGS (NOT TO SCALE) TOP FNDN AT EL. 12.0' MIN ' TED `DUMAS, RS - T ACCESS COVER 70 WITHIN 6" OF FIN. GRADE ACCESS COVER (WATERTIGHT) TO ENGIN EER± I� nlnr 4I I nwFD ) I// COLLEEN PELLEY SEPTI_ C DESIGN: (GARBAGE DISPOSER IS " WI'HIN 6" OF FIN. GRADE 27 SLOPE REQUIRED OVER SYSTEM 9 75 WITNESS: I SPOT ,ELEVATION - 110 GPD 440 GPD MINIMUM .75' of COVER OVER PRECAST 4/24/99 DESIGN FLOW: 4_ BEDROOMS (110 GPD) ) _ DATE: RUN PIPE LEVEL 2" DOUBLE WASHED PEASTONE 0.75' min cover USE A 440 GPD DESIGN FLOW < 2 MIN/INCH =2f >POT ELEVATION FOR FIRST 2' PERC. RATE _ SEPTIC TA 440 GPD 880 9.60' 9.0' PROPOSED 1500 CLASS 1 SOILS P# CONTOUR 1500 GALLON SEPTIC 8.90 JJ USE A GALLON SEPTIC TANK 9.15' LANK (H- 10) GAS �g�g� 8,65' o 'ONTOUR LEACHING: BAFFLE g 2' 8.58' ELEV. 58 (✓77� = 48.9 0.58' 0 8.0' „ Q 8.6' SIDES: 2 45 + 12 gc .25§?. (? %SLOPE) �6" CRUSHED STONE OR MECHANICAL 45 X 12 (74) =99.6 COMPACTION. (15.221 [21) BOTTOM: DEPTH OF FLOW `1_ (_1_7. SLOPE) (� SLOPE) FILL TOTAL: 606 S.F. 448'5 GPD 3/4" TO 1 1/2" DOUBLE WASHED STONE TEE SIZES: 10 25" USE 45' X 12' LEACH FIELD OF 2 ROWS EACH OF 6 INLET DEPTH = STANDARD INFILTRATORS EACH, WITH 2' STONE AT SIDES, OUTLET DEPTH = 14_ A 5 LEACHING LS 2.3' BETWEEN ROWS AND 3.75' AT ENDS FOUNDATION- 22 SEPTIC TANK 5' D' BOX FACILITY OYR 3/3 ASSESSORS MAP 26 PARCEL 142 9 31" ZONING DISTRICT: R25 B YARD SETBACKS: LS FRONT = 30' BOARD OF HEALTH USE ADJUSTED WATER AT ELEV. 3,0' 1OYR 4/6 SIDE = 15' MA (TIDALLY INFLUENCED) 38 5.4' APPROVES DATE NOTE: DWELLING F0071NC•S MUST BE MIN. 2' ABOVE REAR = 20' ADJUSTED GROUNDWATER • ELEVATION (I.E. BASE OF PLAN REF. - LCP 21122A FOOTING TO BE AT MINIMUM ELEVATION OF 5.0') C FLOOD ZONE: FLOODZONE FOUNDATION DESIGN BY OTHERS MS V15 EL. 16, V9 EL. 14 AND A9 EL. 10 (HOUSE IS IN FLOODZONE A9 EL. 10) 84" OBS WATER 1.3' 187 LOT COVERAGE: DECK AND DWELL., .I_ PROP. ROCK RETAINING WALL, TOP AT EL. 9.0'. PROVIDE 40 MIL 89" ?.5Y 7/3 1.18' LINER ALONG INTERIOR OF WALL, TOP AT EL. 9.0', BOTTOM AT + 7.4 5' REMOVAL OF UNSUITABLE SOIL REQUIRED NOTES. Q �-F 7.4 AROUND PERIMETER OF LEACHING FACILITY, _ i 8.1 DOWN TO SUITABLE SOIL LAYER.REPLACE WITH CLEAN MED. SAND. NGVD / 1. DATUM IS cr 2. MUNICIPAL WATER IS AVAILABLE I�� EXIST. DWELL. 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 10 Q 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 1 J6 \ 5. PIPE JOINTS TO BE MADE WATERTIGHT 9'3 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. + B 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE s \ USED FOR LOT LINE STAKING. sa � 98 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 90 BENCH MARK -I TOP OF CONC. � / �PORTION of NEW ,a, 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT GV, INED BOUND. ELEV. 8.3 (NC D) �� O82 ���� FOUNDATION To P P� � �a jx/> EAL H AND PERMISSION 0 ^ \_ FE SLAB INSPECTION BY BOARD OF H T BTA FROM BOARD OF HEATH a \ > 10. CONTRACTOR SHALL BE ,LSFONS:BI.F r OR \/r RIF 'LNG I Hr .J `I J. ALL Vryl�lliJU� UvCt(';.. _r.V I.ILLIIILJ I-'ilIUK /\ / 5. �" / �Fl ,,i: _ COMMENCEMENT C,' WORK. LUG >. TO �. SER /,/ \ / 11. PROVIDE DRYWELLS TO CONTAIN ALL ROOF RUN-OFF. `��� + 24,479± LOT SQ. FT. Sg PREP �! o'a / // // - O GRA + 9.0 > PON 94 TI TL E S SITE PLAN ea5�a',v -- TEST HOLE I. OGS OF - \\ M e�oQ�� 9 10.3 25 SHORE SIDE DRIBE "�` ENGINEER: AH OJALA, PE IN THE TOWN OF: 5/7/03 HATCHED AREA). / /..3 DATE: (SOUTH) YA R M 0 U TH EXISTING DWELLING ( i g TO BE RAZED AND DEBRIS DISPOSED \/y PRF"P PERC. RAT OF AT AN APPROVED SITE E _ < 2 MIN/IP CH \ - - _ 8.zPREPARED FOR: FRAN POLITO Rts5 / CLASS I SOILS P''I _ +.30 a 720 0 20 440 6i0 ` .z sa. - i 5.6 \ 1 PROPOSED OOD ELEVATED BOARDWALK OVER EXIST. PATH ti F"AFTI EXIST. LANDING/STAIRS \V/ F' S^ SCALE: 1" _ 20' DATE: MAY 7, 2003 O REV 7/11/03 (DIST) /i .4 FILL _. REV 7/22/03 (ORYWELL NOTE) EXIST. DWELL. 9. 16"E 4 - G P / / MS g�PGN R I 7 1000 r 3 / 18„ 10YR 7/1 G0PSS / � B . 0.1 10.0 k �F 9 �6 LS 5.9 �1`� / tJE�tib 32" 7.5YR 5/6 3' C IP� Fix 1 EXIST. LANCING/STAIRS / MS OF 2.5Y 6/6 OBS WATER ) 2' �'94 _ : FLOODZONE V9 EL. 14 vv „ L.S. DA TF. \\)C) \ fox 509-362-4541 1 '\ V fax 503 3e2-9880 clown cape engineering, inc. I / CIVIL ENGINEERS LAND SURVEYORS 939 main st, yarmouth, ma 02675