HomeMy WebLinkAbout22.154 - Proposed Septic DesignJ HENCiD[IIRIC SOIL TEST TOP OF FOUNDATION 20 FT. MINIMUM FROM CELLAR DATE OF SOIL TEST ELEV. _ 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE SOIL TEST DONE BY _____ CLEAN SAND WITNESSED BY (ASSUMED) CONCRETE COVERS LOAM AND SEED OBSERVATION HOLE 1 ELEV.=---_ 4" SCHEDULE 40 PVC PIPE PERCOLATION RATE MINJIINCH AT INCHES MIN. PITCH 1/8" PER FT. 2" LAYER OF --_ _—_ DEPTH HORIZ I TEXTURE COLOR MOTT. OTHER 1/8" TO 1/2- 4" CAST IRON Pll'E MAX. WASHED STONE VENT (OR EQUAL) MINIMUM MIN. NOT REQUIRED PITCH 1/4" PER 'FT. z 1 CU. FT. OF CONCRETE FLOW LINE m ANCHOR PLUMBING ELEV. _ —__�_ MIN. IN TO BE RAISED ELEV. _ �_ 2'0" VL= o ° ��������` 192 00000aoeoo �� -- ��� o ° o o X AND RE -PIPED BY LICENSED PLUMBER ELEV. = GAS ELEV. _ 6" SU ELEV. ee ° ELEV. AS NEEDED _ BAFFLE DISTRIBUTION LIQUID OUTLET ELEV. _ V HIGH CAPACITY INFILTRATORS WITH DEPTH TEE(TO BE PLACED ON FIRM BASE) BOX —� STONE IN AN 4 FEET 14 INCHES 5 FEET 19 INCHES TO BE WATER TESTED 1500 GALLON IF MORE THAN ONE OUTLET TRENCH FORMATION WATER ENCOUNTERED AT ELEV. 6 FEET 24 INCHES 7 FEET 29 INCHES (TO BE PLACED ON FIRM BASE) h SOIL ABSORPTION WELL N A ______ _ S FEET 34 INCHES SEPTIC TANK ZONE 3/4" TO 1 1/2" CLEAN SYSTEM (SAS) INDEX DOUBLE STONE FREE OF FINES &SIILTE ADJUST - CALCULATIONS SEWAGE DISPOSAL SYSTEM PROFILE USGS PROBABLE WATER TABLE ELEV. = NUMBER OF BEDROOMS GARBAGE DISPOSAL UNIT NOT TO SCALE OBSERVED WATER TABLE ( / / ) ELEV. _ BOTTOM OF TEST HOLE ELEV. _ TOTAL ESTIMATED FLOW ______ GAL./DAY REQUIRED SEPTIC TANK CAPACITY GAL. ACTUAL SIZE OF SEPTIC TANK _—_ GAL. SOIL CLASSIFICATION _ DESIGN PERCOLATION RATE < MIN./IN. 9� 97.8 EFFLUENT LOADING RATE GAL./DAY/S.F. LEACHING AREA SQ. FT. BENCHMARK: c Naim aE4 'lloaoo LEACHING CAPACITY (AREA X RATE) GAL./DAY RESERVE LEACHING CAPACITY GAL./DAY \ NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN RULES AND REGULATIONS FOR THE SUBSURFACE 99.8 DISPOSAL OF SEWAGE. \ 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WIT'r N 6" OF FINISHED GRADE. HICOMPONENTS 3. ALL OF THE SANITARY SYSTEM SHALL BE CAPABLE OF 100.6 WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN FT. Q8.7 �G 10 OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. pp �Op " 8. 4. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. " 99.3 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO EX DWELLING OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR �ry4 -9 IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS 1100.4 'so PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. (100) \ 8. PARCEL IS IN FLOOD ZONE ---C--- 9. LOT IS SHOWN ON ASSESSORS MAP _— AS PARCEL 15_. 10. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER, AND FOR A MINIMUM OF 5 FEET FROM AROUND THE SOIL ABSORPTION SYSTEM, \ AND BE REPLACED WITH SAND AS SPECIFIED IN 310 CMR 15.255: (3) (I.E. TITLE 5) IF ENCOUNTERED BELOW S.A.S. PIPE INVERT. .�S So k 11. EXISTING SEPTIC SYSTEM TO BE PUMPED AND FILLED WITH SAND �tHOF'�A9 o= R081 OR REMOVED WILLI m OWNERS U. POLE 98.8 W3 1y APPROVED: BOARD OF HEALTH \� \ � suFv�°P DRIVE v / \ 0RAEL 2386 DATE AGENT " 98.7`8• " 98 8/ \ PROPOSED SEPTIC DESIGN ; FOR LOT AREA KEVIN POWELL 19,026--& SF-. 98.6 LQQ• 53 SILVER LEAF LANE I WEST YARMOUTH, MASS. ml � CRAIG R SHORT P.R 'ROAD �Z,2p j 235 GREAT WESTERN LfAF MASS. I 3988311 SOUTH DENNIS, 02660 LOCUS DATE SCALE NOV 15, 2002 1" = 20' • 99.3 REVISED JOB N012-0983 .00ATION MAPREV SED SHEET 1 OF 1 - Q• 58 PRO,12386-00 dw 2386-DO.DWG C 2002 CRAIG R. SHORT, P.E.