HomeMy WebLinkAbout7 Stone Avenue Site Plan of Land 2GAS DO LE WASHED STONE u 7 5 // 5.3r 7.05 BAFFLiE 6.75 9 OUTLET B MIL POLY) LLD -BOX VAPOR �OBSERY£D BARRIER 1500 GAL H-10 e H-10 PUMP CHAMBER SEPTIC TANK WATERTIGHT AND - GROUNDWATER. £L •I.9 WATERTIGHT AND FACTORY WATERPROOFED 20'x 30' LEACH FIELD FACTORY WATERPROOFED 6' CRUSHED STONE OR 7� 7 COMPACTED BASE I\r PROFILE: Nor TO SCALE 1 V GENERAL NOTES: BOUYANCY CALCULATIONS: I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION SEPTIC TANK DISPLACEMENT - (2.5-2.3) x 10.5 x 5.67 - 12 C.F. OF THE SEWAGE DISPOSAL SYSTEM AND PERMITTING 12 C.F. x 62.4 */C.F. - 749*, H-10 TANK - 11480* OK PURPOSES ONLY. PUMP CHAMBER DISPLACEMENT - (2.5-2.0) x 8.5 x 4.83 - 21 C.F. 2. VERTICAL DATUM IS NGVD. FOR BENCH MARKS 21 C.F. x 62.4 */C.F. - 1311*. H-10 TANK - 8240* OK SET. SEE $1 TE PLAN, 3. LIMIT OF WETLAND VEGETATION WAS DELINEATED BY HAMLYN CONSULTING. LIA41T OF COASTAL BANK WAS DELINEATED BY ENSR. 4. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS, D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 5. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 6. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 7. SEPTIC TANK. PUMP CHAMBER AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE. WATERTIGHT AND WATERPROOF. D -BOX SHALL BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE 1S MORE THAN ONE OUTLET. B. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 9. SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION OF THE SYSTEM TO ALLOW FOR SCHEDULING OF THE CONSTRUCTION INSPECTIONS. THE FOLLOWING INSPEC- TIONS SHALL BE DONE AT A MINIMUM: I. DURING THE REQUIRED EXCAVATION. 2. FOOTING FORMS AND REBAR PRIOR TO POURING J. WALL FORMS AND REBAR PRIOR TO POURING. 4. FINAL INSPECTION OF SEPTIC TANK. PUMP AND LEACHING FIELD PRIOR TO BACKFILLING. 10, ALL UNSUITABLE MATERIAL IFILL AND PEAT) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND TO A DEPTH OF 12'-16' AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. 11. ANY RETAINING WALL SHOWN ON THIS PLAN IS FOR LOCATION ONLY AND SHALL CONSTRUCTED IN ACCOR- DANCE WITH THE DESIGN PROVIDED ON A SEPARATE SHEET. 12. /T SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. 13. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. lT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. \ LEWIS BAY LOCUS MAP VARIANCES REQUIRED: TITLE 5. MAXIMUM FEASIBLE COMPLIANCE SECTION 15.211:(1) MINIMUM SETBACK DISTANCES 10' IS REQUIRED BETWEEN THE SEPTIC TANK AND THE PROPERTY LINE. 8' lS PROVIDED. A 2' VARIANCE IS REQUESTED. 10' IS REQUIRED BETWEEN THE PUMP CHAMBER AND THE PROPERTY LINE. 2' IS PROVIDED. AN 8' VARIANCE IS REQUESTED. 10' IS REQUIRED BETWEEN THE PUMP CHAMBER AND THE CELLAR WALL. 5' IS PROVIDED. A 5' VARIANCE IS REQUESTED. 10' IS REQUIRED BETWEEN THE SAS AND THE PROPERTY LINE. 4' IS PROVIDED, A 6' VARIANCE IS REQUESTED. TOWN OF YARMOUTH SUBSURFACE DISPOSAL OF SEWAGE REGULATIONS REGULATION 3.7: DISTANCES A LOCATION OF DISPOSAL FACILITIES 50'IS REQUIRED BETWEEN THE SEPTIC TANK AND THE WETLAND. 45' IS PROVIDED, A 5' VARIANCE IS REQUESTED. 100' IS REQUIRED BETWEEN THE SAS AND THE WETLAND, 70' IS PROVIDED TO THE TOP OF BANK. A 30' VARIANCE IS REQUESTED. GEC CB/DISK FND caer ��..8 /9 e,4- _ 0 VEGETATED WE 5 40 o't o BVWP4 ~0, 4. -- -_ .a4'`4. /'UPF6 L- o C'Rf. - !�0. /!\ Y /S\ • /cBP3/ Ale 00 / t Vol 2 / \ y - CBr4_-pdo' s COOS TPOI le mi r s.z i ' I CD,Y - ' CDFJ - r co 50 JO' LE CH !EL 'Co SOIL REM AL el `o SE£ NOTE RETAIWING Ll. A Po ,; \\ LOTS S. T. U. &_ �°',• `;' \ `\ UPLAND -19.240t S.F. \ '<< CDR 5.5 INv-Ls `,. WETLAND,760' S. F. \ \\ TOTAL -20.'000:t S. F. \\ y ho LYfPd UN / COASTAL D i CDP LMN Ico'*\\\\,. 6' CD*;\O4- • � A'a A A v - \ =O BV R5 / �l .' / t) 5.0 if 1P ---n ----- -wORK(IM k`, ` /h � ~ ESSPOOL CESSPood � C4� 1500 GAL *9C,F SEPTIC TANK Q / PUMP R' CHAMBER \S1 �\ +� f+ ► RETAINING WAIL TOP EL 9/0 \ ►0 �o METER PIT 5.3N� .nC 4090 �OAb\jaA1+ ' �J i'n`n '�•' 7 I +- / +5,5 b \ r / �\ \\ PUMP SYSTEM NOTES: '` 4' PVC INLET `. � !. PUMA TO BE WEBS RESIDENTIAL SEWAGE PUMP MODE! SRM4 �- \\a OR EQUAL. _ \ 2. THE PWP SHALL START AND STOP AT THE ELEVATIONS SHOWN. 3. THE PUMP SHALL BE INSTALLED IN STRICT CONFORMANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND TITLE V REGULATIONS. PUMP DISCHARGE SHALL BE 2 INCHES. PUMP SHOULD BE ABLE TO BE DISCONNECTED AND LIFTED OUT OF THE PUMP CHAMBER WITHOUT HAVING TO ENTER THE PUMP CHAMBER. 4. THE ALARM SHALL START AT THE ELEVATION SHOWN AND BE POWERED BY A CIRCUIT SEPARATE FROM THE PUMP POWER. S. AN ELECTRICAL PERMIT MUST BE OBTAINED FOR THIS INSTALLATION. DESIGN CRITERIA: COUPL 9' MINIMUM COVER 7.25 YER[URY FLOAT INVERT FIRST 2' TO 7.05 sW/TCMEs ACCESS COVERS MUST BE WITHIN OUT SEPTIC TANK: BE LEVEL 4* PERF PIPE OLE 6' OF FINISH GRADE 6.75 TEE 4'YENT MIN. 2' OF 6.5 PIMP P' CWCK VALVE IN DIST. BOX: PEASTON£ S.S' RAW 9.35 MIN 1# Id- MIN IWP OFF d•s PWP OUT DIST. BOX: 8.15 0 8 ........... .. ............... 8.32 - 0��e a -4• REINFORCED CONCRETE 4' IAM PIP 7.25 �� 6 8 SEPTIC TANK PROVIDED: 1500 GAL. MIN. 2' SCH 40 PVC 8. 15 6 5 6.1 yy I • sotlD PIP£ 3/4' - r rig' DIA 8.0 RETAINING WALL GAS DO LE WASHED STONE u 7 5 // 5.3r 7.05 BAFFLiE 6.75 9 OUTLET B MIL POLY) LLD -BOX VAPOR �OBSERY£D BARRIER 1500 GAL H-10 e H-10 PUMP CHAMBER SEPTIC TANK WATERTIGHT AND - GROUNDWATER. £L •I.9 WATERTIGHT AND FACTORY WATERPROOFED 20'x 30' LEACH FIELD FACTORY WATERPROOFED 6' CRUSHED STONE OR 7� 7 COMPACTED BASE I\r PROFILE: Nor TO SCALE 1 V GENERAL NOTES: BOUYANCY CALCULATIONS: I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION SEPTIC TANK DISPLACEMENT - (2.5-2.3) x 10.5 x 5.67 - 12 C.F. OF THE SEWAGE DISPOSAL SYSTEM AND PERMITTING 12 C.F. x 62.4 */C.F. - 749*, H-10 TANK - 11480* OK PURPOSES ONLY. PUMP CHAMBER DISPLACEMENT - (2.5-2.0) x 8.5 x 4.83 - 21 C.F. 2. VERTICAL DATUM IS NGVD. FOR BENCH MARKS 21 C.F. x 62.4 */C.F. - 1311*. H-10 TANK - 8240* OK SET. SEE $1 TE PLAN, 3. LIMIT OF WETLAND VEGETATION WAS DELINEATED BY HAMLYN CONSULTING. LIA41T OF COASTAL BANK WAS DELINEATED BY ENSR. 4. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS, D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 5. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 6. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 7. SEPTIC TANK. PUMP CHAMBER AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE. WATERTIGHT AND WATERPROOF. D -BOX SHALL BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE 1S MORE THAN ONE OUTLET. B. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 9. SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION OF THE SYSTEM TO ALLOW FOR SCHEDULING OF THE CONSTRUCTION INSPECTIONS. THE FOLLOWING INSPEC- TIONS SHALL BE DONE AT A MINIMUM: I. DURING THE REQUIRED EXCAVATION. 2. FOOTING FORMS AND REBAR PRIOR TO POURING J. WALL FORMS AND REBAR PRIOR TO POURING. 4. FINAL INSPECTION OF SEPTIC TANK. PUMP AND LEACHING FIELD PRIOR TO BACKFILLING. 10, ALL UNSUITABLE MATERIAL IFILL AND PEAT) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND TO A DEPTH OF 12'-16' AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. 11. ANY RETAINING WALL SHOWN ON THIS PLAN IS FOR LOCATION ONLY AND SHALL CONSTRUCTED IN ACCOR- DANCE WITH THE DESIGN PROVIDED ON A SEPARATE SHEET. 12. /T SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. 13. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. lT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. \ LEWIS BAY LOCUS MAP VARIANCES REQUIRED: TITLE 5. MAXIMUM FEASIBLE COMPLIANCE SECTION 15.211:(1) MINIMUM SETBACK DISTANCES 10' IS REQUIRED BETWEEN THE SEPTIC TANK AND THE PROPERTY LINE. 8' lS PROVIDED. A 2' VARIANCE IS REQUESTED. 10' IS REQUIRED BETWEEN THE PUMP CHAMBER AND THE PROPERTY LINE. 2' IS PROVIDED. AN 8' VARIANCE IS REQUESTED. 10' IS REQUIRED BETWEEN THE PUMP CHAMBER AND THE CELLAR WALL. 5' IS PROVIDED. A 5' VARIANCE IS REQUESTED. 10' IS REQUIRED BETWEEN THE SAS AND THE PROPERTY LINE. 4' IS PROVIDED, A 6' VARIANCE IS REQUESTED. TOWN OF YARMOUTH SUBSURFACE DISPOSAL OF SEWAGE REGULATIONS REGULATION 3.7: DISTANCES A LOCATION OF DISPOSAL FACILITIES 50'IS REQUIRED BETWEEN THE SEPTIC TANK AND THE WETLAND. 45' IS PROVIDED, A 5' VARIANCE IS REQUESTED. 100' IS REQUIRED BETWEEN THE SAS AND THE WETLAND, 70' IS PROVIDED TO THE TOP OF BANK. A 30' VARIANCE IS REQUESTED. GEC CB/DISK FND caer ��..8 /9 e,4- _ 0 VEGETATED WE 5 40 o't o BVWP4 ~0, 4. -- -_ .a4'`4. /'UPF6 L- o C'Rf. - !�0. /!\ Y /S\ • /cBP3/ Ale 00 / t Vol 2 / \ y - CBr4_-pdo' s COOS TPOI le mi r s.z i ' I CD,Y - ' CDFJ - r co 50 JO' LE CH !EL 'Co SOIL REM AL el `o SE£ NOTE RETAIWING Ll. A Po ,; \\ LOTS S. T. U. &_ �°',• `;' \ `\ UPLAND -19.240t S.F. \ '<< CDR 5.5 INv-Ls `,. WETLAND,760' S. F. \ \\ TOTAL -20.'000:t S. F. \\ y ho LYfPd UN / COASTAL D i CDP LMN Ico'*\\\\,. 6' CD*;\O4- • � A'a A A v - \ =O BV R5 / �l .' / t) 5.0 if 1P ---n ----- -wORK(IM k`, ` /h � ~ ESSPOOL CESSPood � C4� 1500 GAL *9C,F SEPTIC TANK Q / PUMP R' CHAMBER \S1 �\ +� f+ ► RETAINING WAIL TOP EL 9/0 \ ►0 �o METER PIT 5.3N� .nC 4090 �OAb\jaA1+ ' �J i'n`n '�•' 7 I +- / +5,5 b \ r / �\ \\ PUMP SYSTEM NOTES: '` 4' PVC INLET `. � !. PUMA TO BE WEBS RESIDENTIAL SEWAGE PUMP MODE! SRM4 �- \\a OR EQUAL. _ \ 2. THE PWP SHALL START AND STOP AT THE ELEVATIONS SHOWN. 3. THE PUMP SHALL BE INSTALLED IN STRICT CONFORMANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND TITLE V REGULATIONS. PUMP DISCHARGE SHALL BE 2 INCHES. PUMP SHOULD BE ABLE TO BE DISCONNECTED AND LIFTED OUT OF THE PUMP CHAMBER WITHOUT HAVING TO ENTER THE PUMP CHAMBER. 4. THE ALARM SHALL START AT THE ELEVATION SHOWN AND BE POWERED BY A CIRCUIT SEPARATE FROM THE PUMP POWER. S. AN ELECTRICAL PERMIT MUST BE OBTAINED FOR THIS INSTALLATION. PUMP DETA IL :NOT TO SCALE USING 1000 GAL. PWP CHAMBER WATERTIGHT AND WATERPROOF Z Pvc OUTLET INVERT ELEVATIONS: DESIGN CRITERIA: COUPL INd 7.25 YER[URY FLOAT INVERT IN SEPTIC TANK: 7.05 sW/TCMEs WEEP OUT SEPTIC TANK: 6.8 BEDROOM EQUALS 440 G.P.D. OLE IN PUMP CHAMBER: 6.75 ALIPY M_ INVERT OUT PUMP CHAMBER: 6.5 PIMP P' CWCK VALVE IN DIST. BOX: 8.32 S.S' RAW IWP OFF d•s PWP OUT DIST. BOX: 8.15 PUMP DETA IL :NOT TO SCALE USING 1000 GAL. PWP CHAMBER WATERTIGHT AND WATERPROOF Z Pvc OUTLET INVERT ELEVATIONS: DESIGN CRITERIA: INVERT AT BUILDING: 7.25 DESIGN FLOW: INVERT IN SEPTIC TANK: 7.05 4 BEDROOMS AT I10 G.P.D. PER INVERT OUT SEPTIC TANK: 6.8 BEDROOM EQUALS 440 G.P.D. INVERT IN PUMP CHAMBER: 6.75 INVERT OUT PUMP CHAMBER: 6.5 NO GARBAGE GRINDER INVERT IN DIST. BOX: 8.32 A LOAMY SEPTIC TANK REQUIRED: INVERT OUT DIST. BOX: 8.15 8 ........... .. ............... 440 G.P.D. X 200# • 680 GAL. INVERT IN LEACH FIELD: e.1 SEPTIC TANK PROVIDED: 1500 GAL. MIN. INVERT END LEACH FIELD: 8.0 40'-- BOTTOM LEACH FIELD: 7.5 SOIL ABSORPTION SYSTEM REQUIRED: HIGH GROUND WATER: 2.5 DESIGN PERC RATE l 5 MIN/INCH OBSERVED GROUND WATER: l.9 SOIL TEXTURAL CLASS - I BOTTOM OF TEST BORING *2: -17.1 EFFLUENT LOADING RATE - 0.74 GPD/SF 48` 440 GPD / 0.74 GPO/SF - 595 S.F. REQUIRED l.? C2 LOAMY PROVIDED. 20'x 30' LEACH FIELD. 6' DEEP AREA - 600 S.F. x 0.74 - 444 G.P.D. re .7 -M -_ 0 10 20 - - 40 0- HORIZON 40'FILL 1 L L SOIL TEST PIT DATA INDICATES _4__ INDICATES PERCOLATION = OBSERVED TEST GROUNDWATER TB *1 TB *2 EXTURE COLOR 5 2 0- HORIZON TEXTURE COLOR 5.2 F40 FILL 19 /.9 PEA T 148 '.......................................... - 7. 1 C I COARSE 2.5Y SAND 6/1 216= PEA T 188' .......................................... -10.5 C I COARSE SAND 200, ......................... I ...... .......... - 1 1. 5 C2 FINE SAND 2/6' .......................................... -11.8 C3 MEDIUM SAND ' -12.8 264- -17.1 DATE: OCTOBER 8. 2002 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: ( 2 MIN/INCH ASSUMED IN Cl TP * / 0' HORIZON TEXTURE COLOR 5.2 A LOAMY SAND 8 ........... .. ............... 4.5 FILL - 40'-- ......................... r........ 1.9 C I SANDY IOYR LOAM 3/1 48` l.? C2 LOAMY SAND 64' ...... .. .................. -0./ C3 MED -COARSE 2.5Y SAND 511......... 96, ........ 2.8 C4 PEAT ORGANIC 156' -7.8 DATE: MARCH 24. 1999 TEST BY: FLAHERTY. STEFANI d BRACKEN WITNESSED BY: AMY VONHONE S/ T E P L A /\/ O/` L A /V C,) 7 S TO/VE A VENUE. MAP 20 . PARCEL 30 WIT S T YA R"(::) U TI -1 , "A PRE -PA REO F O R: OR I-1AROL0 LEV //VE P . O . BOX / 68 . YARMOUTHPOR T. MA 02675 5(-AL_E: / 20 OCTOBER /6. 2002 REVISED: OCTOBER 28. 2002 REVISED: NOVEMBER 1. 2002 E,AGL E SURVEY I NO , 1 NC 923 Routes 6A Yarmouthport MA. 02675 ( 508) 362-8132 ( 508) 432-5333 r ,