Loading...
HomeMy WebLinkAbout7 Stone Avenue Site Plan of Land 3INSPECTION PORTS FOR FAST UNIT TO BE BROUGHT TO FINISH GRADE BLOWER TO BE PLACED Wl THIN 60' OF FAST UNIT VENT nr18' MIN FAST UNIT ACCESS COVERS MUST BE WITHIN 6' OF FINISH GRADE � FIRST 2' TO BE LEVEL 7 TEE7 / 9' MINIMUM COVER 1--4' PERF PIPE Z' SCH 40 PVC j ro'v \6• IDIf 4- SOLID PIPE 3.5 8.1 3/4' - 1 1/2' DIA -18.0 1500 GAL H-20 PUMP CHAMBER H-20 SEPTIC TANK WATERTIGHT AND FAST READY FACTORY WATERPROOFED WATERTIGHT AND FACTORY WATERPROOFED 6' CRUSHED STONE OR COMPACTED BASE PROFILE : Nor TO SCALE BOUYANCY CALCULATIONS: GENERAL NOTES: I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM AND PERMITTING PURPOSES ONLY. 2. VERTICAL DATUM 15 NGVD. FOR BENCH MARKS SET. SEE SITE PLAN. J. LIMIT OF WETLAND VEGETATION WAS DELINEATED BY HAMLYN CONSULTING. LIMIT OF COASTAL BANK WAS DELINEATED BY ENSR. 4. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 5. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 6. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EOUA L 7. SEPTIC TANK. PUMP CHAMBER AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE. WATERTIGHT AND WATERPROOF. D -BOX SHALL BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 8. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 9. SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION OF THE SYSTEM TO ALLOW FOR SCHEDULING OF THE CONSTRUCTION INSPECTIONS. THE FOLLOWING INSPEC- TIONS SHALL BE DONE AT A MINIMUM: 1. DURING THE REQUIRED EXCAVATION. 2. FOOTING FORMS AND REBAR PRIOR TO POURING J. WALL FORMS AND REBAR PRIOR TO POURING. 4. FINAL INSPECTION OF SEPTIC TANK. PUMP AND k LEACHING FIELD PRIOR TO BACKFILLING. 10. ALL UNSUITABLE MATERIAL (FILL AND PEAT) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND TO A DEPTH OF 12'-16' AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. 11. ANY RETAINING WALL SHOWN ON THIS PLAN IS FOR LOCATION ONLY AND SHALL CONSTRUCTED IN ACCOR- DANCE WITH THE DESIGN PROVIDED ON A SEPARATE SHEET. 12. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. 13. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS, SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. 14. INSTALLATION OF FAST UNIT TO BE CERTIFIED BY FAST REPRESENTATIVE. A YEARLY INSPECTION AND MAINTENANCE CONTRACT SHALL BE MAINTAINED WITH THE FAST REPRESENTATIVE. 4'VENT MIN. 2' OF PEASTONE 18' MIN 0 REINFORCED CONCRETE �• RETAINING WALL DOUBLE WASHED STONE .0 7 S 9 OUTLET vi B NIL POLY-� D -BOX VAPOR BARRIER OBSERVED GROUNDWATER, EL -1.9 20 'x 30' LEACH FIELD SEPTIC TANK DISPLACEMENT - (2.5-(-0.7) x I( x 6.17 - 217 C.F. 217 C.F. x 62.4 0/C.F. - 135400. H-20 TANK - 21230+ OK PUMP CHAMBER DISPLACEMENT - (2.5-(-I.0) x 9 x 5.25 - 165 C.F. 165 C.F. x 62.4 0/C.F. - 102960. H-20 TANK - 145000 OK VARIANCES REQUIRED. TITLE 5. MAXIMUM FEASIBLE COMPLIANCE SECTION 15.211:(1) MINIMUM SETBACK DISTANCES 10' IS REOUIRED BETWEEN THE SEPTIC TANK AND THE PROPERTY LINE. 8' IS PROVIDED. A 2' VARIANCE 15 REOUESTED. !0' IS REOUIRED BETWEEN THE PUMP CHAMBER AND THE PROPERTY LINE. 2' IS PROVIDED, AN 8' VARIANCE IS REQUESTED. 10' IS REOUIRED BETWEEN THE PUMP CHAMBER AND THE CELLAR WALL. 5' IS PROVIDED. A 5' VARIANCE IS REQUESTED. !0' IS REOUIRED BETWEEN THE SAS AND THE PROPERTY LINE. 4' 1S PROVIDED. A 6' VARIANCE IS REQUESTED. TOWN OF YARMOUTH SUBSURFACE DISPOSAL OF SEWAGE REGULATIONS REGULATION 3.7: DISTANCES A LOCATION OF DISPOSAL FACILITIES 50'IS REOUIRED BETWEEN THE SEPTIC TANK AND THE WFTLAND. 45' IS PROVIDED. N CB.I OEC CB/DISK FND BYW+B A 5' VARIANCE IS REOUESTED. 100' IS REOUIRED BETWEEN THE SAS AND THE / 0', WETLAND. 70' IS PROVIDED TO THE TOP OF BANK. A 30' VARIANCE IS REOUESTED. F oo . C8.2 ------- OC VEGETATED Wf 48N Bvw.a;. /3 L- / _ ♦ aVW+6 �p 4�?-4,UPRB q /F.F ` 4aA� P=a IMIr F ! o `1 CESSPOOL 4� C£S-1 / \ Op 150P eAL SEPI!C TAN.0 A 1� <11 9<r W IFA_' UNIT °gyp X ` rOd 5R t,,, 'Poe•. - _ Fo L8r1 r \ o. / .`tC}'' \1 l Ott_- •os �\ �\ .P,S, p a1,/ �o i. ♦.♦o /; bt /i PUMPS.e / \ INV -I.6 .'0// , _ `\ % \ µ°.. 0 C4AV8ER / R£TAININ; WALL ` Ca+S .%, TOP - EL 9/0 ♦ /.L ,. METER PITTtyF.♦\ Oe i ,4r, S: � - 'y'f _�,lN o<Cr \� •Q ♦� �Ge',,' ,Od , C0.3 _ 6 o. QOS ,� Q05 , / .�. •' - i' n 0 P`'SP y� i ' .,'P • \% / .� Copp eR' ,' i ro 0 - 0 /20'0 30 L£ CH I£L CDN SOIL REM AL SEE NOTE r \ qy RETAINING CL LOTS'♦ S. T, U. &•, -y� ry UPLAND -19.240* S.F. yq<< Co. t ` `1 LINv-I.s \ WETLAND -760' S.F. �� r`s_ 4k , yo \ TOTAL -20 '000* S.F. CD+6 CORP - 1.00 \ �•\ CDRB DUN OF COASTAL / nom. \♦. � CD+ UWIT CD- lk t \ V ` qt\ ♦ \ PUMP SYSTEM NOTES: 1. PUMP TO BE MY£RS RESIDENTIAL SEWAGE PUMP MODEL 5RM4 4 PVC INLET OR EQUAL. \ 2. THE PUMP SHALL START AND STOP AT THE ELEVATIO'.S SHOWN. 3. THE PUMP SHALL BE INSTALLED IN STRICT CONFORM'♦CE WITH THE MANVFACTURER'S SPECIFICATIONS AND TITLE V REGULATIONS. PUMP DISCHARGE SHALL BE 2 INCHES. PUMP SHOULD P° ABLE TO BE DISCONNECTED AND LIFTED OUT OF THE PUMP CHAMBER WITHOUT HAVING TO ENTER THE PUMP CHAMBER. 4. THE ALARM SHALL START AT THE ELEVATION. SHOWN A•.0 BE POWERED BY A CIRCUIT SEPARATE FROM THE PUMP PCRER, S. AN ELECTRICAL PERMIT MUST BE OBTAINED FOR THIS INSTALLATION. �M � COUP[IN6 7.25 r� 1N SEPTIC TANK: 7.05 �. ) OUT SEPTIC TANK: HOLE INVERT v 1 _ 5.2 4 CNECN PUMP ON OUT PUMP CHAMBER: 6.5 1 INVERT ,moi o r INVERT PUMP OFF PWO 8.15 e -a P 1N LEACH FIELD: 8.1 1.2 INVERT _.1 ) LEWES BAY BOTTOM LEACH FIELD: 7.5 LOCUS MAP 2.5 4'VENT MIN. 2' OF PEASTONE 18' MIN 0 REINFORCED CONCRETE �• RETAINING WALL DOUBLE WASHED STONE .0 7 S 9 OUTLET vi B NIL POLY-� D -BOX VAPOR BARRIER OBSERVED GROUNDWATER, EL -1.9 20 'x 30' LEACH FIELD SEPTIC TANK DISPLACEMENT - (2.5-(-0.7) x I( x 6.17 - 217 C.F. 217 C.F. x 62.4 0/C.F. - 135400. H-20 TANK - 21230+ OK PUMP CHAMBER DISPLACEMENT - (2.5-(-I.0) x 9 x 5.25 - 165 C.F. 165 C.F. x 62.4 0/C.F. - 102960. H-20 TANK - 145000 OK VARIANCES REQUIRED. TITLE 5. MAXIMUM FEASIBLE COMPLIANCE SECTION 15.211:(1) MINIMUM SETBACK DISTANCES 10' IS REOUIRED BETWEEN THE SEPTIC TANK AND THE PROPERTY LINE. 8' IS PROVIDED. A 2' VARIANCE 15 REOUESTED. !0' IS REOUIRED BETWEEN THE PUMP CHAMBER AND THE PROPERTY LINE. 2' IS PROVIDED, AN 8' VARIANCE IS REQUESTED. 10' IS REOUIRED BETWEEN THE PUMP CHAMBER AND THE CELLAR WALL. 5' IS PROVIDED. A 5' VARIANCE IS REQUESTED. !0' IS REOUIRED BETWEEN THE SAS AND THE PROPERTY LINE. 4' 1S PROVIDED. A 6' VARIANCE IS REQUESTED. TOWN OF YARMOUTH SUBSURFACE DISPOSAL OF SEWAGE REGULATIONS REGULATION 3.7: DISTANCES A LOCATION OF DISPOSAL FACILITIES 50'IS REOUIRED BETWEEN THE SEPTIC TANK AND THE WFTLAND. 45' IS PROVIDED. N CB.I OEC CB/DISK FND BYW+B A 5' VARIANCE IS REOUESTED. 100' IS REOUIRED BETWEEN THE SAS AND THE / 0', WETLAND. 70' IS PROVIDED TO THE TOP OF BANK. A 30' VARIANCE IS REOUESTED. F oo . C8.2 ------- OC VEGETATED Wf 48N Bvw.a;. /3 L- / _ ♦ aVW+6 �p 4�?-4,UPRB q /F.F ` 4aA� P=a IMIr F ! o `1 CESSPOOL 4� C£S-1 / \ Op 150P eAL SEPI!C TAN.0 A 1� <11 9<r W IFA_' UNIT °gyp X ` rOd 5R t,,, 'Poe•. - _ Fo L8r1 r \ o. / .`tC}'' \1 l Ott_- •os �\ �\ .P,S, p a1,/ �o i. ♦.♦o /; bt /i PUMPS.e / \ INV -I.6 .'0// , _ `\ % \ µ°.. 0 C4AV8ER / R£TAININ; WALL ` Ca+S .%, TOP - EL 9/0 ♦ /.L ,. METER PITTtyF.♦\ Oe i ,4r, S: � - 'y'f _�,lN o<Cr \� •Q ♦� �Ge',,' ,Od , C0.3 _ 6 o. QOS ,� Q05 , / .�. •' - i' n 0 P`'SP y� i ' .,'P • \% / .� Copp eR' ,' i ro 0 - 0 /20'0 30 L£ CH I£L CDN SOIL REM AL SEE NOTE r \ qy RETAINING CL LOTS'♦ S. T, U. &•, -y� ry UPLAND -19.240* S.F. yq<< Co. t ` `1 LINv-I.s \ WETLAND -760' S.F. �� r`s_ 4k , yo \ TOTAL -20 '000* S.F. CD+6 CORP - 1.00 \ �•\ CDRB DUN OF COASTAL / nom. \♦. � CD+ UWIT CD- lk t \ V ` qt\ ♦ \ PUMP SYSTEM NOTES: 1. PUMP TO BE MY£RS RESIDENTIAL SEWAGE PUMP MODEL 5RM4 4 PVC INLET OR EQUAL. \ 2. THE PUMP SHALL START AND STOP AT THE ELEVATIO'.S SHOWN. 3. THE PUMP SHALL BE INSTALLED IN STRICT CONFORM'♦CE WITH THE MANVFACTURER'S SPECIFICATIONS AND TITLE V REGULATIONS. PUMP DISCHARGE SHALL BE 2 INCHES. PUMP SHOULD P° ABLE TO BE DISCONNECTED AND LIFTED OUT OF THE PUMP CHAMBER WITHOUT HAVING TO ENTER THE PUMP CHAMBER. 4. THE ALARM SHALL START AT THE ELEVATION. SHOWN A•.0 BE POWERED BY A CIRCUIT SEPARATE FROM THE PUMP PCRER, S. AN ELECTRICAL PERMIT MUST BE OBTAINED FOR THIS INSTALLATION. �M � PUMP DETAIL :Nor r0 SCALE USING 1000 GAL. PUMP CHAMBER WATERTIGHT AND WATERPROOF Z_ PVC OUTLET 0 /0 20 40 INVERT ELEVATIONS: INVERT COUP[IN6 7.25 MERCURY FLOAT 1N SEPTIC TANK: 7.05 SWITCHES PEEP INVERT OUT SEPTIC TANK: HOLE INVERT ALARM ON 6.75 5.2 4 CNECN PUMP ON OUT PUMP CHAMBER: 6.5 VALVE INVERT 1N DIST. BOX: 5.3, RAW INVERT PUMP OFF PWO 8.15 e -a P 1N LEACH FIELD: 8.1 1.2 PUMP DETAIL :Nor r0 SCALE USING 1000 GAL. PUMP CHAMBER WATERTIGHT AND WATERPROOF Z_ PVC OUTLET 0 /0 20 40 INVERT ELEVATIONS: INVERT AT BUILDING: 7.25 INVERT 1N SEPTIC TANK: 7.05 INVERT OUT SEPTIC TANK: 6.8 INVERT IN PUMP CHAMBER: 6.75 5.2 INVERT OUT PUMP CHAMBER: 6.5 INVERT 1N DIST. BOX: 8.32 INVERT OUT DIST. BOX: 8.15 INVERT 1N LEACH FIELD: 8.1 1.2 INVERT END LEACH FIELD: 8.0 BOTTOM LEACH FIELD: 7.5 HIGH GROUND WATER: 2.5 96 OBSERVED GROUND WATER: 1.9 BOTTOM OF TEST BORING +2: -17.1 !il 40'FILL I L L DESIGN CRITERIA: DESIGN FLOW: 4 BEDROOMS AT 110 G.P.D. PER BEDROOM EOUALS 440 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 440 G.P.D. X 200% - 880 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REOUIRED: DESIGN PERC RATE ( 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 440 GPD / 0.74 GPD/SF - 595 S.F. REQUIRED PROVIDED: 20'x 30' LEACH FIELD. 6' DEEP AREA - 600 S.F. x 0.74 - 444 G.P.D. SOIL TES T PIT DA TA INDICATES INDICATES PERCOLATION = OBSERVED TEST GROUNDWATER TS sl TB 02 EXTURE COLOR 5.2 0' HORIZON TEXTURE COLOR 5.2 FILL PEA T C I COARSE 2.5Y SAND 6/1 /.9 40 ' /.9 PEA T 188 '.......................................... -10.5 C I COARSE SAND 200 '.......................................... - 1 1 .5 C2 FINE SA NO 216" ................... ........... .... I....... - 12.8 C.3 MED I UM SAND 216'1 1 -12.8 264' DATE: OCTOBER 8. 2002 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: C 2 MIN/INCH ASSUMED IN Cl TP 01 HORIZON TEXTURE - COLOR 0. 5.2 \ LOAMY '4' SAND 6' ....... ...... ...,...... 4.5 FILL 40' _.. ._.. _.... /.9 -C / SANDY IOYR LOAM............3/! 48 1.2 C2 LOAMY SAND 64'- ........ ............. -0.1 C3 MED -COARSE 2.5Y SAND 5/1 96 2 8 C4 PEAT ORGANIC I56' -7.8 DATE: MARCH 24, 1999 TEST BY: FLAHERTY. STEFANI d BRACKEN WITNESSED BY: AMY VONHONE S/ TE_ P L A/\/ O� L A /\/O 7 S TONE A VENUE. MAP 20. PARCEL 30 WE' S T YA R"O U TA -1. "A. P R E P A R E0 FOR : �R H,�R0L0 LEV//VE P . 0. BOX / 68 . YARMOUTh/POR T. MA 02675 SCALE-: / '" - 20 OCTOBER /0. 2002 REVISED: OCTOBER 28. 2002 REVISED: NOVEMBER 25. 2002 EAGLE SURVEYING, INC 923 Route 6A Yormouthpart MA. 02675 508 362-8132 ( 508 ) 432-5333