87.42 - Fire Alarm System
rwmm e S Al � L i:M0211'"1•L1:M020 F]WL1019- j� L1:M018 Scope of work O (New) addressable fire alarm system. The fire alarm control panel and all power supplies are to be mounted in the managers office. They are to be powered by dedicated 120VAC circuits that are to be locked and labeled CIR-2-07 CIR-2-06 CIR-2-05 CIR-2-04 CIR-2-03 CIR-2-02 CIR-Z-OT FIRE ALARM DO NOT TURN OFF. SLC Loo St le 4 0 The fire alarm is to be monitored as a remote station at ADT Security A A C:F 2 (ll 2#16 FPLP L1:D-001 LI.MO02 L1.MO03 L1:M004 LIWO05 L1:MO06 LIWO07 L1:MO08 L1. -M009 LYM010 LIW011 L1:MO12 tl) #14/2 service, Aurora, CO. By a dual line dialer connected to 2 existing shared FP DIR-1-06 CIR-/-05 CIR-1-04 CIR-1-03 CIR-1-02 CIR-1-01 loop start phone lines. ® The following conditions are to be monitored. cit 1 ( 1) #14/2 P CRF MMF O All smoke detector , and monitored as an alarm. FPLP A/c SHUT DOWN 0 Manual pull stations at all exits as alarm. 0 Duct detectors are to be installed in the return duct � i reL i to and monitored as a hone L I ne 1 hone -Line 2. supervisory signal. MS9050UD o The duct detectors are to shut down their own unit when smoke is detectedF-(1)4#18FAA S FPLP in its own unit. ® Occupant notification is to be general alarm. All horns and strobes shall be Butte Butte synchronized. izv'A'� 12v'AI Dedicated 120 VAC 20 Amp Circuit(Locked) General notes: - - 1. All fire alarm devices are to be installed according the the requirements of NFPA 72 -and the manufactures instructions. 2. All fire alarm devices are to be mounted on back boxes. 3. All fire alarm devices are to be UL Listed and compatible. 4. All wire is to be in conduit from the device back box to above the false ceiling or to the bar joists. Wire may be run exposed horizontally but must be attached to the building structure or supported by approved hangers. 5. All wire is to be Power Limited, Type FPLP unless otherwise noted. All wiring is to be installed in accordance with the adapted NFPA 70 (NEC Section 760), NFPA 72 and all local codes. 6. Control panels and power supplies are to be mounted at the electrical panels unless the AHJ requires otherwise. They are to be mounted no more that 72 inches above the floor to the top of the cabinet. 7. Annunciator/Keypads are to be mounted at 54 inches above the floor to the top of the unit unless the AHJ requires otherwise. 8. Manual pull stations are to be mounted at 48 inches above the floor to the center of the box unless the AHJ requires otherwise. 9. Wall mounted horns and strobes shall be mounted at 80 inches to the bottom of the box above the finished floor.The candela rating is noted near the device on the drawings. 10. Ceiling mounted horns and strobes will be noted with a "C".The candela rating is noted near the device on the drawings. 11. Ceiling mounted strobes are spaced based on a ceiling height of 20' all ceilings in the tenet space are 14' or less. 12. The Advance Auto electrical contractor is to supply all required 120VAC to the fire alarm control panel and all power supplies on dedicated Circuit(s). The circuit(s) are to be locked and label "FIRE ALARM DO NOT TURN OFF". 13. The Advance Auto electrical contractor is to supply all conduit stub ups, back boxes, power supply inter connection conduit required and any under ground conduit and wiring to outside devices. The under ground wire is to be THHW or equal. 14. The Advance Auto Mechanical contractor is to supply and install all required duct mounted smoke detectors. Tyco is to connect as point of connection only. 15. The remote test switches will be intalled at the FACP unless otherwise stated by the AHJ 16. Upon completion of the installation 2 sets of plans shall be marked up for as built. one set is to be left on site in a locked cabinet at the fire alarm control panel. The other set is to be returned to Tyco, 01 —,, 11,M-006 I p ..L1:M-004 VIII A L1:M-007 1:M-002 L1:M-003 D D I 1:M-001 a ;ACI?P I L1:M-021 71 LA A e WP w d L l.•M- D D CRF a D LI:M-017 I a L1:M-016 l_J i I 1 I A L1:M-015 1141 1 CIR-1-01 I-1--- CIR-1-01 15CD .E F I IR , 75CD �E - E T� WCIR-1-02 —'75CD_ i CIR-1-07 75CD I� E Ery C CRF A/C SHUT DOWN LY.M013 L1:MO17 F-1 LIW016 L1:MO14I L1:M015 111 MGL AND FIRE TOWN OF YARMOUTH REVIEWED FOR CODE COMPLIANCE. ERRORS OR OMMISSIONS DO NOT RELIEVE THE APPLICANT FROM THE RESPONSIBILITY OF 'AS BUILT COMPLIANCE. DATE: `15,43. IMSPECTOR SEQUENCE OF OPERATION MATRIX - FIRE ALARM SYSTEM Fire Alarm Legend -Nn1T All DFVTCFS RHFIWN nN LEGEND APPEAR ON DRAWINGS - Symbol Qty Description ooii000i■■■■ AWG COND Fire Alarm Control FireLite FACP 1 Panel MS905OUD NO CMP Fire Alarm Annunciator FireLite FFAAI 1 Alpha Keypad ANN -80 FireAlam System Addressable Dual FireLite ® O Monitor Module MDF300 Addressable Monitor FlreLlte —s—.� 2 Module MMF300, MMF301 ®P IS Smoke Detector FlreLlte Photo Electric SD355 Fire Alarm System Manual Pull Station FireLite © 2 BG-12LX Addressable Control FlreLlte CR 2 Module CRF -300 NO FPLP Duct Smoke Detector Supplled by others ? 2 Photo Electric i� Security system Remote Indicator Air Products I�Ars 2 Test/Reset MSR100R/W Water Flow Supplied by others 8 0 Switch Sprinkler Valve Supplied by others 0 Tamper Switch Signal Power Booster Firellte PB 0 FCPS-24FSB Strobe Candella System Sensor SW or SWH ® 3 Indlcated Multi Candella ®C Getting Strobe System Sensor SCW or SCWH 6 Candella Indicated Multi Candella Horn Strobe Candetla System Sensor P2W or P2RK O��r"T�i■�■0�■■■0■■0 Indicated Multi Candella � Ceiling Horn Strobe System Sensor PC2W or PC2WH LIC 4 Candella Indicated Multi Candella Auxilary Power Altronlx AL4000LX Ps 0 Supply "S O Ansul System Relay Point of Connection aoc Connection Supplied by others. K� 1 Knox Box a . , .. ■a■oo■■■o■■o Department for Type Heat Detector R of R Fire Lite H355R l O R 0 135 deg or Indicated SEQUENCE OF OPERATION MATRIX - FIRE ALARM SYSTEM Fire Alarm Legend -Nn1T All DFVTCFS RHFIWN nN LEGEND APPEAR ON DRAWINGS - Symbol Qty Description Manufacture/Part Number AWG COND Fire Alarm Control FireLite FACP 1 Panel MS905OUD NO CMP Fire Alarm Annunciator FireLite FFAAI 1 Alpha Keypad ANN -80 FireAlam System Addressable Dual FireLite ® O Monitor Module MDF300 Addressable Monitor FlreLlte —s—.� 2 Module MMF300, MMF301 ®P IS Smoke Detector FlreLlte Photo Electric SD355 Fire Alarm System Manual Pull Station FireLite © 2 BG-12LX Addressable Control FlreLlte CR 2 Module CRF -300 NO FPLP Duct Smoke Detector Supplled by others ? 2 Photo Electric i� Security system Remote Indicator Air Products I�Ars 2 Test/Reset MSR100R/W Water Flow Supplied by others 8 0 Switch Sprinkler Valve Supplied by others 0 Tamper Switch Signal Power Booster Firellte PB 0 FCPS-24FSB Strobe Candella System Sensor SW or SWH ® 3 Indlcated Multi Candella ®C Getting Strobe System Sensor SCW or SCWH 6 Candella Indicated Multi Candella Horn Strobe Candetla System Sensor P2W or P2RK 0 Indicated Multi Candella � Ceiling Horn Strobe System Sensor PC2W or PC2WH LIC 4 Candella Indicated Multi Candella Auxilary Power Altronlx AL4000LX Ps 0 Supply "S O Ansul System Relay Point of Connection aoc Connection Supplied by others. K� 1 Knox Box Consult Local Fire Department for Type Heat Detector R of R Fire Lite H355R l O R 0 135 deg or Indicated LOW VOLTAGE WIRING LEGEND "SEE GENERAL WIRING NOTES FOR EACH SYSTEM" Line Type Description AWG COND SHIELD CLASS Security system 18 4 NO CMP Data loop / Device Vmng FireAlam System 18 4 NO FPLP Device Wring —s—.� FMAOMSYsfem 18 6 NO FPLP Remote Test SO" Wiring Fire Alarm System 16 2 NO FPLP Data two Wiring Fmokstm System 14 2 NO FPLP Notification Device Wiring —��—m Security system 16 4 NO CMP Device Pawer tarring o the detriment of TYCO without written permission. The recipient further agrees not to disclose the contents to any other party except for the specific purpose contracted for with Tyco. Tyco makes no representations as to the operability or accuracy of any systems, subsystems, This design including specifications, drawings, and design concepts is the property of Tyco Integrated Security. (TYCO), and is furnished on a confidential basis, with the expressed understanding that it will not be sold, transfered, copied, or used t assemblies, or other information contained herein unless specifically identified for Construction. NATIONAL ACCOUNTS GROUP 120 West Park Drive Birmingham, AL 35211 PH: (205) 940.7346 PI: (205) 9424943 TOPRIETARY AND CONFIDENTIAL INFORMATION NOTICE: his proposal, dmwrthg(s) and related doom enta6on(and the information herein contained) is to etary, codideotid and bade sere! idohma5on of Tyco Integrated Seat ('TYCO) and is suppilm upon the egress conditions that (1) the same shall be returned to TYCO upon request, (2) no eproducdon of IS documentation or any pad thereof shall be made without the express written permission of TYCO, Inc. These drawings may contain confidental intonation and should not be dis5rbulod. DRAWING ACCEPTANCE: is draMng Is to be used only for the purpose d placing and loaing TYCO equipment and is not to be used for any other purposes. Is the responsibirity of the local TYCO Sales 8 SKry oe Office (SSO) to rWew the content of these awinos lor accuracy and compliance with local and state codes prior In releasing them to the field. RECORD DRAWINGS: cork perfumed in the field shall be accurately recorded on these drawings and returned to er ADT oRice at the address listed here. Tyco Integrated Searcy 120 West Parc Drke Biminglam,A1.35211 Attention: As -baits MONITORING LOCATION: you Integrated Security Alam Senrce Co.: 360662-Y 4200 EVadon Ave. Service Center Number. 76 umm, Ca 81ID12 UL Listing: SWAB $00-02&7124 GIBBENS DRAKE SCOTT, INC 9201 E 63rd STREET, SURE 100 RAYTOWN, MISSOURI 64133 _ ENGINEERING N0.47676 FG+STERE? �+oiAL For Fire Alarm Support Contact: Mike Olsen, SET NICET #106934 Fire Alarm Systems, Levet III Expires January 01,2015 Tel: (205) 940-7350 ema I L: cc (sen@adt. corn Advance „' Auto Parts .,,. CUSTOMER ADVANCE AUTO PARTS STORE # 7196 447 Station Ave Yarmouth MA 02664 REVISION NOTES NO. DATE INT. DESCRIPTION DRAWN BY CHECKED BY MO MO SHEET TITLE FIRE ALA LAYOUT RISER DATE REF#/JOB# 08-NOV-2012 AAF SCALE SHEET FA1 1/8 " = 1'