Loading...
HomeMy WebLinkAbout151 South Street - Site PlanFIRST FLOOR EL, 11.0' SYSTEM PROFILE TEST HOLE LOGS ACCESS COVER TO WITHIN 6' OF FIN. GRADE (NOT TO SCALE) RICK JUDO, RS ENGINEER: MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM A- FEAMY VON HONE, R5 R12/14/00 6A$$ R 9.4FEMALE ADAPTOR & THREADED PLUG 12 14 `�'°AR1(WAr CRAWLSP J2 EDUCER .1.5'0 THREADED END CONNECTION DATE; / /00 I DRILL LAST HOLE T EACH SCH 40 PVC < 5 MIN/INCH FraDN. 6 0,� PROPOSED �, 4005CH 40 V!! ELBOW •LATERAL ON TOP TO VENT PERC, RATE _ GALLON SEPTIC AIR WHILE LATERAL FILLS BAS' OF 5.0' TANK (H-__iQ_-) 4.75. Q POUR 1.5 CU. FT. - _-•.'`�,- F00 W AT EL. WATERPROOF 3000 PSI CONCCLASS �, - M%TR sr. ( GAs p p SOILS P# CKSCENT CT.4.4' MI 4;MSUPPLIED BY SEPTITECH O THRUST BLOCK1.5"OSCH40 LATERAL � OC81- p p 1 M)N BAFFLE AROUND CONNE__.__O__._._•___--._._____.___-._.-._______._-.___._._._. ._. �___. _ 1p7(TYP.) _ /LERNATE TOP &BOTTOM-•'^_.-__.--�^•^-__F(2�: SLOPE) 6 CRUSHED STONE OR MECHANICAL INVERT LEVEL AT 7.9'LOT J7 • G NOTE: FOUNDATION DESIGN , COMPACTION. (15.221 [2]) - 60" O.C. WITH SHIELDSNOTE: F U DEPTH OF FLOW = `} BOTTOM LEACHING LEVEL AT EL. 7.4' ELEV. LOCUSBY T(�S" SLOPE) (� X SLOPE) H 4D PVC MANIFOLD , 5 5_7. O" Q 6.3' TEE SIZES: � _ - INLET DEPTH = 1D„ 2'OSCH40 PRESSURE LINE FROM PUMP PIT - - 0 0 OUTLET DEPTH m 14" .005 PF /Fr MIN. 7, 6„ LOCATION MAP NO7 TO SCALE USE GROUNDWATER EL 2.4' + A/E A/E 4 1.5'0 SCH-40 PVC LATE ASSESSORS MAP 3RAL ORIFICE SHIELD OS150CW LS LFS PARCEL 264, ORL'NCO SYSTEMS INC r - *SLOTS -800-348-9643 UAL 1/4"e HOLE AT S' O.C.I SNAP-ON ALTERNATE BETWEEN TOPSHIELD & BOTTOM OF PIPE. EXACT DIAMETER HOLES DRAINA SHOULD BE SHOP DRILLE A DRILL PRESS TO ENSURZ UNIFORMITY. REWOV SuRus 15" 7.5YR a/2 t1„ tOYR 5/2 ZONING DISTRICT: RS 40 265 "MONITORING WELLS SET ON LOTS 2 & 3 (ON 3, IN AREA OF PROPOSED LEACHING AREA), AND HIGHEST YARD SETBACKS: READING USED OVER N EW MOON TIDAL CYCLE AND DURING WET TIME OF YEAR Bw Bw FRONT = 30' LMS LMS SIDE = 20' REAR = 20' 36" 7.5YR 4/4 2.7' 7.5YR 4/4 PLAN REF. - 198/111 " PRIOR TO PLACING PIPE. ORIFICE SHIELD DETAIL - 32 3.63' FLOOD ZONE: A11 EL. 11 NOT TO SCALE c G LOT COVERAGE: 6% FS 56" obs. water 1:0' 61 FS s. w obs. water NOTE: LOTS 2 AND 3 ARE TO BE 1.2' COMBINED UNDER AN "APPROVAL NOT REQUIRED PLAN" PROCESS 1OYR 5/4 2.5Y 6/4 98" -2.5 102" -2.2' NOTES: SEPTIC DESIGN: (GARBAGE DISPOSER Is NOT ALLOWED + 6.6 DESIGN FLOW: _3 BEDROOMS ( 110 GPD) = 330 GPD ) 1 • DATUM IS NGVD EB 65 BENCHMARK -CTR. OF CATCH USE A 330 GPD DESIGN FLOW 2. MUNICIPAL WATER IS AVAILABLE BASIN ELEV. = 6.11 (NGVD) SEPTIC TANK: 330 GPD ( 2 ) = $60 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. ! I i USE A 1500 GALLON SEPTIC TANK 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE (NOT TO SCALE) SMALL LEACHING: JOINTS TO BE MADE WATERTIGHT. 6. AREA CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. 6.3 DRAINS N/A SIDES: ENVIRONMENTAL CODE TITLE V. 3 4'B LOT 1 2a ' AREA = 483 SF .74 BOTTOM: - ( ) = 357 GPD 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. J �r 7 ry TOL• 483 S F 357 TA 8. PIPE FOR SEPTIC SYSTEM TO SCH 40-4" PVC GPD U] 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT p �ti• ' I �� USE PRESSURE DOSED LEACH FIELD IN + a CONFIGURATION SHOWN (SEE DETAIL) F 417'f HEALTH AND SS 0 . L,7AIN .- SPECTION BY BOARD OF ALT PERMI I �I. 0� 3 •T C" _ _, ROM BOARD OF HEQ'=TH •ELECT`�iCiJ,�;<IAI I.C4Uli..p. -. +5.1 PROP, DWELL. W ` !� 11. ALL ROOF RUN-OFF TO BE DIRECTED TO DRYWELLS/TRENCHES k + ss + s, c a• 12. SIGNED MAINTENANCE CONTRACT REQUIRED TO BE SUBMITTED PRIOR TO ISSUANCE OF PERMIT. LOT 2 S + 4.6 °`� okn 1, 13. PROVIDE STANDARD TESTING QUARTERLY FOR FIRST YEAR 14966+/- SQ. FT, " ZX LEGE WITH RESULTS TO BE SUBMITTED TO HEALTH DEPT, � �' � (UPLAND) �� �` _ � `fl •� 6.s .� Ci7 ' THE FOLLOWING PARAMETERS SHALL BE MONITORED`. PH, BOD, 5 40 "' STAIR oo �� 100.0 PROPOSED SPOT ELEVATION TSS, 7KN, NITRATES AND NITRITES EVERY TIME THE SYSTEM IS w ' MONITORED. THE WATER METER READING SHALL ALSO BE - � 100x0 EXISTING SPOT ELEVATION RECORDED. I ,�3.9 / 0 11 9 Ln r - PROP. 1500 GAL, SEPTIC TANK 100 14• INITIAL 2 YEAR CONTRACT REQUIRED WITH SEPTITECH FOR 8 3 �K 26 -5 + s.7 (SUPPLIED BY SEPTITECH) PROPOSED CONTOUR MAINTENANCE AND TESTING, YEAR TO YEAR CONTRACT REQUIRED 3v S as- - - 7 9 THEREAFTER. CONTRACT TERMS TO BE APPROVED BY HEALTH DEPT. 2.1 ale 50• ' -PROP. SEPTITECH PROCESSOR 100 - EXISTING CONTOUR M UNIT MODEL M40ON 15. INSTALLATION TO BE IN ACCORDANCE WITH SEPTITECH k 393'* - A ® O SPECIFICATIONS AND CERTIFICATION BY SEPTITECH RECUIRED, / TH1 OO � 6.3 4.1 mm �- - FROM SEPTITECH ,!e L � UNIT / 802,6, TITLE 5 SITE PLAN K 3.3 OF LOTS 2 & 3 SOUTH STREET h i 1 IN THE TOWN OF: 3 .c 0EELLE•VAATION8.4'.NG BLOCK WALL, PRO DE 40 MIL SER "� � (SOUTH) YARMOUTH 1,8 •{ 3.6 LOT 3 AROUND PERIMETER OF SAS (AT 5' OFF), TM2 ( J TOP EL. A7 0.4', BOTTOM AT EL. 4.4' M4* SCH 40 ANIFOLD PVC SQ. FT. po I A PREPARED FOR: ARTHUR FORZIATI + 6.3 ` � 3E ' (UP AND 4, 1 348'1 1 Ak i 1 4.2 fpp 1.5' SCH. 40 30 0 30 g�-0 -- 90 /jam- LATERALS(TYP) ^� 1 7 1 rp 1 2.0 F VARIANCES REQUESTED: i "�- SCALE: 1"= 30' DATE: NOVEMBER 25, 2002 YARMOUTH REG. 3.7: PRIMARY SAS TO BE 80' FROM EDGE OF `` TTYP ESTPRESR SUE _�.„�` 'BEV. 12/30/02 (FAST) WETLAND (20' VARIANCE): RESERVE TO BE 53' FROM EDGE OF 21.5 WETLAND (4FIN. GRADE FOR i", In OF REV, 6/10/03 (SEPTITECH) • T VARIANCE). NOTE: IF PRIMARY SHOULD FAIL. IT IS ALL LATERALS LOT 4 Mq ;�a�%'` '(1J• REV, 6/24 _ 3L TO BE REPLACED IN ITS ENTIRETY. WITHIN SAME AREA PRESSURE DOSE FIELD DIMENSIONS ELBOWS PROVIDE SWEEP -�`'�� ERNE J��3. ARNE H, y�yG REV. 6/30/03 (NOTES)) ' (NOT TO SCALE) H. o OJALq 15.211: REDUCTION IN SETBACK, PRIMARY AND RESERVE SAS TO 4') O�� °•' CIVIL TO PROPERTY LINE (10' G No. 26346 oalE n No. 30792 w �`s F7Cr5i �� aar% POf STE �4tQ �41 ,,per_O L t ttYTNE" H. OJALA, DA - �!I �� - REOUIRED INSPECTIONS AND CERTIFICATIONS • ! i 1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION IS NJ SFP2 4 2003 � I� COMPLETE. 2.ER SHALL INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY - DEPOSITED _ 2 3. ENGINEER SHALL STAKE PROPOSED WALL r ff{ 4. ENGINEER SHALL INSPECT SOS-362-4541SPECT AND CERTIFY WALL AND SEPTIC COMPONENTS Offfox 508 362-8880 I - ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT - L�OWY) CQp[-' eY)giY)E'erii?g, inc. RETAINING WALL AND SEPTIC SYSTEM HAVE BEEN INSTALLED IN SUBSTANTIAL COMPLIANCE WITH THE APPROVED PLAN. CIVIL ENGINEERS + LAND SURVEYORS APPROVED DATE z_ MA 939 Main St. yarrlouth, ro, 02675