HomeMy WebLinkAbout151 South Street - Site Plan 2FIRST FLOOR EL. 11.0' SYSTEM PROFILE
ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE)
MINIMUM .75' OF COVER OVER PRECAST 29. SLOPE REQUIRED OVER SYSTEM
REDUCER
CRAWLSP J=
FNDtI' PROPOSED 1500 Ur 4'OSCH 40 PVC 90' ELBOW
6.0'f GALLON SEPTIC k -__._._._.-.-._.-._._._--
POUR 1,5 CU. FT. MIN.
BASE OF 5.0' TANK (H- 1 ) 4.75' q
3000 PSI CONC.
FOOTING A7 EL � WATERPROOF �Y ". L4-OSCH
�� 1.5"mSCH40
4 d 11th!?UM SUPPLIED BY $� CH �$ THRUST BLOCK .t. �_-.-.-.__-_-.-.
.� BAFFLE AROUND CONNECTION "+!RISER
MIN (TYP.) VARIES .
(-2-7 SLOPE) 6" CRUSHED STONE OR MECHANICAL 7 4
NOTE: FOUNDATION DESIGN COMPACTION. (15.221 [2])
BY OTHERS DEPTH OF FLOW 4'. (1 SLOPE) (-L-% SLOPE) \ 40 PVC MANIFOLD
TEE SIZES:
INLET DEPTH = }0" 2'OSCH40 PRESSURE LINE FROM PUMP PIT
OUTLET DEPTH >= 14"PITCH
DOS FT/FT MIN.
ORIFICE SHIELD OS150CW
1.5"0 SCH-40 PVC LATERAL ORENCO SYSTEMS INC
PH. 1-800-348-9843
OR EQUAL PRESSURE DOSE SPECIFICATIONS:
PERFORATION SIZE: 1/4" DIAM.
1/4.0 HOLE AT 5. O.C. SNAP-ON PERFORATION SPACING: 5' O.C.
ALTERNATE BETWEEN TOP SHIELD LATERAL DIAM: 1.5"
& BOTTOM OF PIPE. MANIFOLD DIAM: 4"
EXACT DIAMETER HOLES DRAINAGE SLOTS PERFORATIONS ON ADJACENT
SHOULD BE SHOP DRILLED WrrH LATERALS TO BE STAGGERED
A DRILL PRESS TO ENSURE
TEST HOLE LOGS
ENGINEER: RICK JUDD, RS
WITNESS' AMY VON HONE, RS
UNIFORMITY. REMOVE BURRS
PRIOR TO PLACING PI?E. ORIFICE SHIELD DETAIL
NOT TO SCALE
+ 6.6
EB6.5 BENCHMARK - CTR. OF CATCH
BASIN ELEV. = 6.11 (NGVD)
SMALL
(NOT TO SCALE) - E'..REA
6.3 GRAINS
355 4.e LOT 1
2,1
LMS
7.5YR 4/4
FEMALE ADAPTOR & THREADED PLUG
DATE: 12/14/00.
3.63'
C
C
1.5"0 THREADED END CONNECTION
DR LL LAST HOLE IN EACH SCH 40 PVC<
5 MIN/INCH
FERC. RATE _
1,0' 611,obs.
F
water
1.2'
LATERAL ON TOP TO VENT:.:
1OYR 5/4
2.5Y 6/4
AIR WHILE LATERAL FILLS
�,4.
I
2.1
----------------------- __._ __-__.,_____
-• -'-'---- _.T
.GLASS - SOILS
P#
_-_-_..____._._._.__-______._._.
O r/O O�O O rR 01
�._._____._ .-.__.__a-....-qs-pJ
\ 1/4" ORIFICE ALTERNATE TOP & BOTTOM
INVERT LEVEL AT 7.9'
�ijOTTOM
LOT
3
60" O.C. WITH SHIELDS
LEACHING LEVEL AT EL. 7.4'
4 - ELEV.
Ep
5_7'
0"
6.3'
5
0
0
7„
6„
USE GROUNDWATER EL.
2.4' + '
A/E
A/E
LS
LFS
7.5YR 5/2
11„
10YR 5/2
15,.
*MONITORING WELLS SET ON LOTS 2 & 3
(ON 3, W AREA OF PROPOSED LEACHING AREA), AND HIGHEST
BW
Bw
READING USED OVER N EW MOON TIDAL CYCLE AND DURING WET TIME OF YEAR
UNIFORMITY. REMOVE BURRS
PRIOR TO PLACING PI?E. ORIFICE SHIELD DETAIL
NOT TO SCALE
+ 6.6
EB6.5 BENCHMARK - CTR. OF CATCH
BASIN ELEV. = 6.11 (NGVD)
SMALL
(NOT TO SCALE) - E'..REA
6.3 GRAINS
355 4.e LOT 1
2,1
00-229 2 &3
Le
Ak
k
Ak-
I
2.0
4"
I .7 6.3
ro
+ 4.7
417'1 I 3.7' C.;
4 { 4.1 1 W ' 4
PROP. DWELL. I 1
1
+3"
+ 5.5
_e n
1 LOT 2 S + 4.6
14966+/- SQ. FT. Y \ tK q ,O
(UPLAND) � ,�
_ _
k 5 4.0 P STAIR O
tX
011 .9 N PROP. 1500 GAL. SEPTIC TANK
'5 + 5.7 * { (SUPPLIED BY SEPTITECH)
.- -413.7 3 9 2.6
X3.5- - 7 9 50' PROP. SEPTITECH PROCESSOR
�L UNIT MODEL M40ON
R M ®
393'1 / THi o } e;a
4.1
Lm N 1
/ +6.7 /
K3.3 1
1
+ 2 PROP. INTERLOCKING BLOCK WALL,
^v 4 O ELEVATION 8.4'. PROVIDE 40 MIL
AROUND PERIMETER OF SAS (AT 5-
J 3,6 LOT 3 1 1 ` TOP EL AT 6.4, BOTTOM AT EL. 4,
9000+/- SQ. FT. + 6.3
ale I (UP AND 4
I 1
348'1: 4.21
7
I
VARIANCES REQUESTED:
YARMOUTH REG. 3.7: PRIMARY SAS TO BE 80' FROM EDGE OF
WETLAND (20' VARIANCE), RESERVE TO BE 53' FROM EDGE OF
WETLAND (47' VARIANCE). NOTE: IF PRIMARY SHOULD FAIL, IT IS
LOT 4 TO BE REPLACED IN ITS ENTIRETY, WITHIN SAME AREA
15.211: REDUCTION IN SETBACK, PRIMARY AND RESERVE SAS
TO PROPERTY LINE (10' TO 4')
REQUIRED INSPECTIONS AND CERTIFICATIONS
1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION IS
COMPLETE. - -
2. ENGINEER SHALL INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY
DEPOSITED _
3. ENGINEER SHALL STAKE PROPOSED WALL
4. ENGINEER SHALL INSPECT AND CERTIFY WALL AND SEPTIC COMPONENTS
ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT
THE RETAINING WALL AND SEPTIC SYSTEM HAVE
BEEN INSTALLED IN SUBSTANTIAL COMPLIANCE WITH THE APPROVED
PLAN.
36"
LMS
7.5YR 4/4
2.7'
32"
4
3.63'
C
C
56"
FS
obs. water
1,0' 611,obs.
F
water
1.2'
1OYR 5/4
2.5Y 6/4
98"1
2.1
-2.2'
00-229 2 &3
Le
Ak
k
Ak-
I
2.0
4"
I .7 6.3
ro
+ 4.7
417'1 I 3.7' C.;
4 { 4.1 1 W ' 4
PROP. DWELL. I 1
1
+3"
+ 5.5
_e n
1 LOT 2 S + 4.6
14966+/- SQ. FT. Y \ tK q ,O
(UPLAND) � ,�
_ _
k 5 4.0 P STAIR O
tX
011 .9 N PROP. 1500 GAL. SEPTIC TANK
'5 + 5.7 * { (SUPPLIED BY SEPTITECH)
.- -413.7 3 9 2.6
X3.5- - 7 9 50' PROP. SEPTITECH PROCESSOR
�L UNIT MODEL M40ON
R M ®
393'1 / THi o } e;a
4.1
Lm N 1
/ +6.7 /
K3.3 1
1
+ 2 PROP. INTERLOCKING BLOCK WALL,
^v 4 O ELEVATION 8.4'. PROVIDE 40 MIL
AROUND PERIMETER OF SAS (AT 5-
J 3,6 LOT 3 1 1 ` TOP EL AT 6.4, BOTTOM AT EL. 4,
9000+/- SQ. FT. + 6.3
ale I (UP AND 4
I 1
348'1: 4.21
7
I
VARIANCES REQUESTED:
YARMOUTH REG. 3.7: PRIMARY SAS TO BE 80' FROM EDGE OF
WETLAND (20' VARIANCE), RESERVE TO BE 53' FROM EDGE OF
WETLAND (47' VARIANCE). NOTE: IF PRIMARY SHOULD FAIL, IT IS
LOT 4 TO BE REPLACED IN ITS ENTIRETY, WITHIN SAME AREA
15.211: REDUCTION IN SETBACK, PRIMARY AND RESERVE SAS
TO PROPERTY LINE (10' TO 4')
REQUIRED INSPECTIONS AND CERTIFICATIONS
1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION IS
COMPLETE. - -
2. ENGINEER SHALL INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY
DEPOSITED _
3. ENGINEER SHALL STAKE PROPOSED WALL
4. ENGINEER SHALL INSPECT AND CERTIFY WALL AND SEPTIC COMPONENTS
ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT
THE RETAINING WALL AND SEPTIC SYSTEM HAVE
BEEN INSTALLED IN SUBSTANTIAL COMPLIANCE WITH THE APPROVED
PLAN.
36"
LMS
7.5YR 4/4
2.7'
32"
I LMS
7.5YR 4/4
3.63'
C
C
56"
FS
obs. water
1,0' 611,obs.
F
water
1.2'
1OYR 5/4
2.5Y 6/4
98"1
-2.5 102"
-2.2'
SEPTIC DESIGN: (GARBAGE DISPOSER Is NOT ALLOWED )
DESIGN FLOW: 3 BEDROOMS (110 GPD) = 330 GPD
USE A-330 GPD DESIGN FLOW
SEPTIC TANK: 330 GPD ( 2 } = 660
USE A 1500 GALLON SEPTIC TANK
LEACHING:
SIDES: N/A
BOTTOM: AREA = 483 SF (.74) = 357 GPD
TOTAL: 483 S.F. 357 GPD
USE PRESSURE DOSED LEACH FIELD IN '
CONFIGURATION SHOWN (SEE DETAIL)
LEGENQ
100.0 PROPOSED SPOT ELEVATION
100x0 EXISTING SPOT ELEVATION
100 PROPOSED CONTOUR
100- EXISTING CONTOUR
FROM SEPTITECH
UNIT
/ 1
1
/ 1
4' SCH 40 PVC / Lp 1 trt
MANIFOLD 1 J
IF
1 .'-
I � 1
I � t
/ 1
1\ / � 1 1.5" SCH. 40
dI
�� LATERALS(TYP)
11 �,
V� TYP PRESSURE
TEST/C.O. TO
21.5 FIN. GRADE FOR
ALL LATERALS -
PROVIDE SWEEP
PRESSURE DOSE FIELD DIMENSIONS ELBOWS
(NOT TO SCALE)
APPROVED DATE
, MA
SA$SmVTR pA ,xr
I
(OVER ST.
CRESCENT CT
Locus / €'
LOCATION MAP NOT TO SCALE
ASSESSORS MAP 34 PARCEL 264,
ZONING DISTRICT: RS 40 265
YARD SETBACKS:
FRONT = 30'
SIDE = 20'
REAR = 20'
PLAN REF. - 198/111
FLOOD ZONE: A11 EL, 11
LOT COVERAGE: 6%
NOTE: LOTS 2 AND 3 ARE TO BE
COMBINED UNDER AN "APPROVAL
NOT REQUIRED PLAN" PROCESS
NOTES:
1. DATUM IS NGVD
2. MUNICIPAL WATER IS AVAILABLE
3. MINIMUM PIPE PITCH TO BE 1/8 PER FOOT.
4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10
5. PIPE JOINTS TO BE MADE WATERTIGHT,
6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS.
ENVIRONMENTAL CODE TITLE V.
7, THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE
USED FOR LOT LINE STAKING,
8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC,
9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT
INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED
FROM BOARD OF HEALTH.
10. ELECTRICAL PERMIT REQUIRED.
PRIOR
TO ISSUANCE OF PERMIT. /
1. L ROOFRUN-6r, FO BE OIRLC I L.0 10 UK i 4VLLLJ I I?Lf ,LHL.> ii
12. SIGNED MAINTENANCE CONTRACT REQUIRED TO BE SUBMITTED
13. PROVIDE STANDARD TESTING QUARTERLY FOR FIRST YEAR
WITH RESULTS TO BE SUBMITTED TO HEALTH DEPT.
THE FOLLOWING PARAMETERS SHALL BE MONITORED: PH, BOD,
TSS, TKN, NITRATES AND NITRITES EVERY TIME THE SYSTEM IS
MONITORED. THE WATER METER READING SHALL ALSO BE
RECORDED.
14. INITIAL 2 YEAR CONTRACT REQUIRED WITH SEPTITECH FOR
MAINTENANCE AND TESTING. YEAR TO YEAR CONTRACT REQUIRED
THEREAFTER. CONTRACT TERMS TO BE APPROVED BYHEALTH DEPT.
15. INSTALLATION TO BE IN ACCORDANCE WITH SEPTITECH
SPECIFICATIONS AND CERTIFICATION BY SEPTITECH REQUIRED,
TITLE 5 SITE PLAN
OF LOTS 2 & 3 SOUTH STREET
IN THE TOWN OF: •
(SOUTH) YARMOUTH
PREPARED FOR: ARTHUR FORZIATI
30 0 30 60 90
SCALE: 1" = 30' DATE: NOVEMBER 25, 2002
REV. 12/30/02 (FAST)
,✓ " Uy ` REV. 6/10/03 (SEPTITECH)
i�H�Of O�,a,%, 1tT 3�'IJj REV. 6/24/03 (NOTES)
ARNE ARAEH REV. 6/30/03 (NOTES)
OJALA N
OJAL�
No 26eCIVIL v;
48 a C� ,o 0, 30792
A yo
STE-
U AL V16
AYt�1'E H. OJALA, P,L,S. DATE
Lp I
ani �C�
t
nv
'I .OiFD
4
�!
oft 508-362=4541
fax 508
I
dawn cape engineering, inc,
CIVIL ENGINEERS
LAND SURVEYORS
939 Main st. yormouth, mo, 02675