Loading...
HomeMy WebLinkAbout3 South West Drive - Sewage Disposal Design'IT DATA _ TEST PIT _#2- _ GRD. EL. 10.2 - SHGW EL. 2.6 7" EL 10.0 14" EL. 11.2 311, EL. 7.5 64" _ 92" 100" 112" EL 1.2 6/17/10 BSC GROUP, INC. AMY VON HONE < 2 MIN./INCH BRIAN YERGATIAN, P.E. CLASS 1 0.74 GPD/S.F. A LOAMY SAND 10YR 3/2 E MEDIUM SAND 2.5Y 6/3 Bw LOAMYSAND 1018 5/8 Cl MEDIUM SAND 2.5Y 7/3 ESTIMATED �_- SEASONAL HIGH GROUNDWATER OBSERVED GROUNDWATER PERCOLATON 3" TEST RANGE UNSUITABLE 12" MATERIALS (TO BE REMOVED) 32" 91" 99" 108" SEASONAL HIGH GROUNDWATER ADJUSTMENT MIN/INCH NDATION 13.50 DEPTH TO OBSERVED WATER 8.3 INDEX WELL MIW-29 WATER LEVEL RANGE ZONE A DEPTH 0 INDEX WELL (5/10) 6.7 ' WATER LEVEL ADJUSTMENT 0.7 DEPTH TO ADJUSTED WATER 7.6 ' M: N. G. V. D. 3ET: NAIL SET IN UTILITY POLE ELEVATION 9.94 NGVD ZOFILE ION - 4' SCH. 40 PVC L-19 FT. S=0.02 EPTIC TANK TAPE SHALL BE PROVIDED ALL PVC PIPING 4" SCH. 40 PVC L-4 FT. . S=0.02 FIRST PIPE LENGTH TO BE SET LEVEL, FOR MIN. 2' FINISH GRADE E .=10.0-10.5 4" PVC SCH 40 - LEACHING FIELD- - - ot 1=GJ 5 OUTLET 5.1' SEPARATION D -BOX I K EST. HIGH GROUNDWATER OF ELEVATIONS DESIGN PERC. RATE: <2 MIN/INCH NDATION 13.50 A T BUILDING 9.38 B ,T SEPTIC TANK (IN) 9.00 C ,T SEPTIC TANK (OUT) 8.75 D ,T DIST. BOX (IN) 8.67 E �T DIST. BOX (OUT) 8.50 F MATERIAL AND DELETRIOUS SUBSTANCES. LEACHING FACILITY: CLASSES OF SOIL SHALL NOT BE USED. FILL SHALL NOT CONTAIN ANY MATERIAL BEGINNING OF LEACHING FIELD 8.35 G (BREAKOUT 8.8) END OF LEACHING FIELD 8.20 H 4T BOTTOM OF LEACHING FIELD 7.70 J 11GH GROUNDWATER 2.6 K CRAIG A. FIELD v No.38039 t 0/ [ I a' I pr� \ PROPOSED WATER SERA CE MAIN AND SERVICE TO BE CONFIRMED WITH NATER DEPARTMENT I LEACHING FIELD DETAIL NOT TO SCALE ! OVER LEACHING SLOPE FELD I v � Shy \\ a 4" PERFORATED WO v SCH. 40 PVC PIPE \ o (TYP.) o. \ a�c0i � 5' OVERDIG \'` `~- -- -' ..r �'•-.,...-r° `` \. / � \ NOTE: b OUTH WEST DRIVE \ ;1 / / \ \ \ \ BEGEOTEXTILE (FOR MAY \ (PRIVATE-40`WIDE) 2" PEASTONE LAYER Irv\ \ / y.,,, _ 10- S33 36'00"E �,, 146.50' J p p PROPOSED RESERVE AREA 20'x30' [ DISTRIBUTION BOX N DETAIL (H-1DA NOT TO SCALE REMOVABLE 3• 2" WALLS COVER F -1L .-T: 00 11-1/2" 2" J BOTTOM ON LEVEL STABLE BASE 6" MINIM SFGTON NEW 3/4" TO CRUSHEC STONE (5) 5" DIA. 13" I KNOCKOUTS I 21" PLAN VIEW NOTES: 1. DIST. BOX To WITHSTAND H-10 LOADING UNLESS UNDER PAVEMENT, DRIVES OR TRAVELED WAYS WHEREIN H-20 LOADING SHALL APPLY. 2. PROVIDE INLET TEE OR BAFFLE WHERE SLOPE OF PIPE EXCEEDS 0.08 FT./FT OR IN PUMPED SYSTEM. 3. FIRST TWO FEET OF PIPE OUT OF DIST. BOX TO BE LAID LEVEL 4. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 5. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. 6. CONCRETE COVER SHALL BE RAISED TO WITHIN 6 INCHES OF FINISHED GRADE. OG 1,500 GALLON SEPTIC TANK (H -10i SCALENOT TO NOTES 1. SEPTIC TANK SHALL BE STEEL REINFORCED CONCRETE. MIN. 20" DIA. COVER, TYP. 2. SEPTIC TANK SHALL BE CAPABLE OF +WTHSTANDING H-10 RAISE (2) TO WITHIN 6" OF FINISHED LOADING. I GRADE USING SEWER BRICK AND 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION MORTAR AS NECESSARY SHALL BE WATERTIGHT. 4. TEES SHALL BE SCH. 40 PVC AND SHALL BE LOCATED 6" MAX WITHIN 12" OF TANK WALL AND ACCESSIBLE FROM TANK COVER, 5. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. yAy y y�a�;yayy� y 6. IF ANY PORTION OF THE GROUND SURFACE ABOVE TANK WILL BE SUBJECT TO VEHICLE LOADS, AN H-20 Cl�0"f 4" SEPTIC TANK SHALL BE REQUIRED. 10'-6" _ f --- 10'-0" _ 4' MIN. PRECAST SEPTIC TANK LIQUID DEPTH S' -S" �(SHOREY OR APPROVED EQUAL) 4•_6" LOCATE a INLET TEE 90' ELBOW ON IO O = UNDER COVER OUTLET TEE r 3" 5'-8" I + 3" , ------- -� � .y f 6" MINIMUM CROSS-SECTION VIEW PLAN VIEW 3/4" TO 1-1/2"� CRUSHED STONE 0 ! [ 14.0•\ DRIVEWAY ! °' 9.0 ( i0.0 m I „-.•1 11.0 3B, / 04 _, _ 6 9 14.0' \ f 40.0' BREAKOUT .t Cli PROPOSED j'� / PANEL N GARAGE a SLAB = 11.2 ROPOSED DWELUNV T.O.F. = 13.5 ✓✓ CRAWL SPACE FLOOR SLAB - 10.51/. PFOPOSED 1,500 GALLON _/ SEPTIC TANK PROPOSED 5 -OUTLET DISTRIBUTION BOX - EDGE OF 20' X 30' LEACHING FIELD BREAKOUT PANEL 10.4 12" MIN. COVER 30' PROFILE 3/4" TO 1 -1/2 - DOUBLE WASHED STONE CONTAINING NO FINES -1 FILE Copy OCT 2 9 2010 2" MIN. OF 1/" TO 2" WASHED PEAS ONE UILDINGDEPT 4" MIN. LOAM AND SEED END CAP I (TYP.) / BENCHMARK: \ NAIL SET IN \ UTILITY POLE. \ ELEVATION 9.94 ` 3 rn/ Gvg4, ` l r 0 o hOs,P CROSS-SECTION DESIGN CALCULATIONS DESIGN FLOW: 4 BEDROOMS 0 110 GPD/BDRM = 440 GPD REQUIRED SEPTIC TANK: 440 GALLONS X 200% = 880 GALLONS SEPTIC TANK PROVIDED = 1,500 GALLONS SIZE OF LEACHING FACILITY REQUIRED: DESIGN PERC. RATE: <2 MIN/INCH LONG TERM APPL. RATE: Mlb 440 GPD _ 0.74 GPD/SF = 595 S.F. 2. ALL CONSTRUCTION METHODS AND SIZE OF LEACHING FACILITY PROVIDED: 15.000 AND YARMOUTH BOARD OF USE LEACHING FIELD BOTTOM = 20' x 30' = 600 S.F 600 S.F X 0.74 SF/GPD / BENCHMARK: \ NAIL SET IN \ UTILITY POLE. \ ELEVATION 9.94 ` 3 rn/ Gvg4, ` l r 0 o hOs,P CROSS-SECTION DESIGN CALCULATIONS DESIGN FLOW: 4 BEDROOMS 0 110 GPD/BDRM = 440 GPD REQUIRED SEPTIC TANK: 440 GALLONS X 200% = 880 GALLONS SEPTIC TANK PROVIDED = 1,500 GALLONS SIZE OF LEACHING FACILITY REQUIRED: DESIGN PERC. RATE: <2 MIN/INCH LONG TERM APPL. RATE: 0.74 GPD/S.F. 440 GPD _ 0.74 GPD/SF = 595 S.F. 2. ALL CONSTRUCTION METHODS AND SIZE OF LEACHING FACILITY PROVIDED: 15.000 AND YARMOUTH BOARD OF USE LEACHING FIELD 3. THERE ARE NO KNOWN OR PROPOSED BOTTOM = 20' x 30' = 600 S.F 600 S.F X 0.74 SF/GPD = 444 GPD VARIANCES REQUESTED NONE 40.0 LOCUS INFORMATION 1 " 0 CURRENT OWNER: LISA AND NDA BYRNE O b PROPOSED DE TITLE REFERENCE: CTF. 192453 16'x24' 6. PLAN REFERENCE: LCP. 18413 y ASSESSORS MAP: 25 l PARCEL: 304 QS r _ -- ZONING DISTRICT: R-25 30' SETBACKS: FRONTSIDE 20 REAR S ::•I s - s �" ` °-` I MINIMUM LOT SIZE: 25,000 S.F. \ EXISTING TOTAL LOT AREA: 11,875t S.F. NITROGENSENSITIVE s-�s------[ '•' ZONE: NOT A ZONE II %s FEMA FLOOD S ZONE DISTRICT: "A9" ELEU 10 & "B" 01001, OVERLAY DISTRICT: NONE / ' / LOCUS MAP'rcutn Hculth Depa OBSERVATION PORT � / � 3 � NOT TO SCALE i n 28 PROPOSED LIMITS OF E�l�p \ J ' 5 OVERDIG AND REMOVAL OF 5�1 1 0 UNSUITABLE MATERIALS CRONCRETEs / BOUND FOUNDY �1 �k 7b z � ` E Cl ON LINE P�J� 1 0 �T �O w v z N � p° ° D SHED PLAN VIEW ��°�° / PROPOSE _ SCALE: 1' 9'x12 = 10 FEET _ Locus / / SOUTH SHORE DR. 0 5 10 20 FT, \ . \ NANTUCKET SOUND REVISIONS NO, DATE DESCRIPTION 1 9/20/10 NEW HOUSE GENERAL NOTES: 1. THIS PLAN IN ONLY INTENDED FOR THE DESIGN AND CONSTRUCTION OF THE DWELLING & SEWAGE DISPOSAL FACILITY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO 310 CMR 15.000 AND YARMOUTH BOARD OF HEALTH REGULATIONS. 3. THERE ARE NO KNOWN OR PROPOSED PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY. 4. IF AN OVERDIG IS SPECIFIED, REMOVE ALL TOPSOIL, SUBSOIL AND OTHER UNSUITABLE MATERIALS. 5. IF AN OVERDIG IS SPECIFIED, REPLACE ALL EXCAVATED MATERIALS WITHIN THE LIMIT OF EXCAVATION WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND DELETRIOUS SUBSTANCES. MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL SHALL NOT BE USED. FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 2 INCHES. A SIEVE ANALYSIS USING A #4 SIEVE SHALL BE PERFORMED ON A REPRESENTATIVE SAMPLE OF FILL. UP TO 45% BY WEIGHT MAY BE RETAINED ON THE #4 SIEVE. SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SPECIFICATIONS: 100% MUST PASS #4 SIEVE 10% MUST PASS #50 SIEVE 0-20% MUST PASS #100 SIEVE 0-5% MUST PASS #200 SIEVE 6. EXISTING UTILITIES WHERE SHOWN ON THE PLANS ARE APPROXIMATE. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL SUBSURFACE STRUCTURES ARE SHOWN. CONTRACTOR SHALL VERIFY THE SIZE, LOCATION AND ELEVATION OF INVERTS OF UTILITIES AND STRUCTURES, WITHIN THE LIMIT OF WORK, PRIOR TO THE START OF CONSTRUCTION. IF ANY DISCREPANCIES ARE DISCOVERED OR FIELD CHANGES REQUIRED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY COORDINATING THE PROPOSED CONSTRUCTION ACTIVITIES WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANIES, AND SHALL COMPLETE THE PROPOSED WORK WITHOUT ANY INTERUPTIONS IN SERVICE. 8. CONTRACTOR IS REQUIRED TO NOTIFY DIG -SAFE, PER MASS. STATUTE CHAPTER 82, SECTION 40 (1-888-344-7233) A MINIMUM OF 72 HOURS PRIOR TO THE START OF CONSTRUCTION. 9. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. INSTALLATION OR USE OF A GARBAGE GRINDER AT THIS PROPERTY IS NOT ALLOWED PER 310 CMR 15.240(4). BSC G]1:01LJ l 349 Route 28, Unit D W. Yarmouth, Massachusetts 02673 508 778 8919 @2010 BSC Group, Inc. 1W1Fp) PROJECT TITLE: 20,I(0 j HEALTH DEPT. DESIGN , RIMPI , SEWAGE DISPOSAL SYSTEM #3 SOUTH WEST DR. m nt So. YARMOUTH M ASSACH U SETTS PREPARED FOR: Mr. BILL REPOSA 112 ACADEMY ROAD, ##3 BRIGHTON, MA 02135 (1-617-610-8922) REPOSA.BILL@GMAIL.COM DATE: JUNE 27, 2010 COMP. DESIGN: B. YERGATIAN CHECK: K. HEALY DRAWN: K. HEALY FIELD: P. HAGIST FILE NO. 49515-SEP.DWG DWG NO. 6011-01 JOB NO. 4-9515.00 SHEET 1 OF i