HomeMy WebLinkAbout11 South West Drive Sewage Disposal Design 2LOCUS MAP SCALE: 1 " = 500' awN Roo _� TOP OF FOUNDATION, T OF CONCRETE 13.60 CRAWL SPACE TOP of SLAB 9.60 INVERT OF PIPE AT FOUNDATION 11.22 INVERT AT SEPTIC TANK NLET 10.97 INVERT AT SEPTIC TANK 10.72 INVERT AT DISTRIBUTION BOX INLET 10.56 INVERT AT DISTRIBUTION BOX OUTLET 10.39 INVERT AT CHAMBER IN 10.17 ELEVATION OF TRENCH 60TTOM 9.00 FINISHED GRADE OVER LEACHING AREA (F.G.)-- 11.8 GROUND WATER ELEVATI N 3.80 BREAKOUT ELEVATION 10.71 NOTES: 1.) SEE SOIL TEST LOGS AND PLAN FOR LEACHING FIELD REQUIRED EXCAVATION DEPTH AND LIMITS. SOAK Z. SITE IS WITHIN 100 FLOOD PLAIN AE -11 ZONE BUT IS NOT WITHIN A NITROGEN SENSITIVE NOTE THE LOT I3 GRANDFATHER. THE LOT WAS CREATED IN 1956. l AP m uff Das Ina® W°P tfmsu / AP M >ff 3U WV=10.97 (00 BUTTING SM 4' SOL 40 PVC OR CAST F011rBR LEAD NO MW JOINTS I■ mi 6-12' E SAND 5YR 8/1 STEP 1 MEASURE DEPTH TO WATER TABLE TO NEAREST 1/10 FT. DATE 11/14/14 6-17" E SAND 5YR 8/1 8.9 STEP 2 USING WATER -LEVEL RANGE ZONE � �0•� taxa_ � ! / 17-54" B SAND 7YR 5/8 AND INDEX WALL MAP LOCATION 48-120' C SAND IOYR 6/6 0.4 SITE AND DETERMINE: 0.3 CONCRETE BOUND (FOUND TYPICAL) ® APPROPRIATE INDEX WELL W2 GROUNDWATER WEEPING 0 108' 1.30 (() WATER -LEVEL RANGE ZONE SOUTH / w ta�c�euala STEP 3 USING MONTHLY REPORT "CURRENT CAPE COD COMMISSION TECHNICAL BULLETIN 92-001 Ile (GRAVEL ROAD) fo8ae>SErxsM>E SOAK _9 BENCHMARK DETERMINE CURRENT DEPTH TO ' I ELEV. WATER LEVEL FOR INDEX WELL 11/14 8 I ELEV. / / �tsiEMoosM 1w$Mmtt> srMm lmm / STEP 4 USING TABLE OF WATER -LEVEL ADJUSTMENTS EL 10.39 1 9mirm NAVD 1988 TO WATER LEVEL FOR INDEX WELL (STEP 3), eaMD AND WATER -LEVEL ZONE (STEP 28) plrau) SOUTH WEST DRIVE DETERMINE WATER -LEVEL ADJUSTMENT5 SCALE: 1 " = 20' STEP 5 ESTIMATE DEPTH TO HIGH WATER ASSESSORS MAP 25 LOT BY SUBTRACTING THE WATER TW OF EE� LEVEL ADJUSTMENT (STEP 4) 13-IM39 NAW 1988 FROM MEASURED DEPTH TO WATER - FRONT YARD = 30' SIDE YARD = 15 REAR YARD = 20' (CURRENT CONVENTIONAL SYSTEM LAYOUT PROFILE OF SYSTEM 9' CULTEC CHAMBER APPROVAL IN ACCORDANCE WITH THE MODIFIED CERTIFICATION FOR GENERAL U FOR CULTEC FOLLOWING (Or 70 3r"AlE) ' CHAMBERS DATED FEBRUARY 22, 2010 PURSUANT TO TITLE 5, THE 9" CALCULATIONS ADDRESS SECTION IV "CONDITIONS APPLICABLE TO THEI SYSTEM OWNER' THAT A 3 CO OBSERVATION PIPE man OF 36" VER g' IN WHICH A SYSTEM FOR NEW CONSTRUCTION SHALL DEMONSTRATE OVER SY51E11 ( FYUSH GRAD, t PER TRENCH CONVENTIONAL ABSORPTION SYSTEM USING AGGREGATE CAN BE INSTALLED ON THE 6' fR011 EkOSt1 GRADE GRASS SIINFACE SIZE. MAGILBC TAPING SEE CONSTRUCTION NOTE 7 ON SHEEP 2 MIN. FG.=124 _17.T. 2X NVtlYIlW SLOPE DESIGN DATA- OMGN F1 Oft 5 BEDROOM SINGLE FAMILY DWELLWG 1 I I- -. 7" NUMBER OF BEDROOMS X 110 GAL/DR/DAY - DESIGN FLOW MAGNETIC TAPING FIVE (5) BEDROOMS X 110 GALA R/DAY - 550 GAL/DAY (GPD) 7" I EACHNG FA YIY (CONVENTIONAL TRENCH PIPE do STONE) RESEARCH BY: JWN SOIL IMURAL QASS (310 CMR 15.243) (SANDS, LOAMY I (SLOAMY SANDS) 6' DESIGN PERCOLATION RATE: t2 MIN./ N. KGM/JWN LANG 1ERM ACCEPTANCE RATE (310 CMR 15.242) 0.74 GPD/SQ. FT. 6" FIELD SURVEY: DESIGN FLDW (GPD) / LTAR (GPO/SQ. FT.) - MILL LEACHING AREA (SQ. FT.) COMPUTED BY: JWN 550 GPID / 0.74 GPD/SQ. Fr. - 743 SQ. FT. REQUIRED. RATE: RATE: DATE 11-14-14 SYSTEM AREA PROVIDED (so- Fr.) - # OF TRENCHES x LENGTH OF TRENCH x DATE: DATE: DRAFTED BY: DRD BPG / [(2X EFFECTIVE DEPTH) + WIDTH] so2 X 54 X [(2 X 2) + 31 756 &F DEPTH: DEPTH: DESIGNED BY: BPG �O ' 743 SJ: REWIRED. EXCAVATION AREA REQUIRED a 641ONG BY 25' WIDE WITH 5' OVERING HAS BEEN PERFORMED CONSISTENT WITH THE REQUIRED TRAINING, EXPERTISE, EXPERIENCE DESCRIBED CHECKED BY. BJW DATE REVISION TITLE 5 SEWAGE DISPOSAL SYSTEM 2 12 15 ADJUST ELEVATION OF SDS DWELLING 3 17 15 ADD DRIP EDGE TO C 11 SOUTH WEST DRIVE 4 1515 C NSERVATION COMMISSION COMMENTS YARMOUTH, MA 02601 24' RAItIw WW AfmLY REHOVABE APPLICANT RECORD OWNER: LvffEARE COVERS OF OL ME YAl[RIAL UK F.G.=12.5 24' IABARON FMARY GEORGE & JANA TARASENKO b' mm OF FINISH 87 PATRICKS RUN LAH244 RM AND COVER STOUGHTON, MA 02072 508-889-5992 AT 6RAOE OR APPROVED EQUAL ClfAHOUf J - 4 SM 40 PVC WV=10.97 (00 BUTTING SM 4' SOL 40 PVC OR CAST F011rBR LEAD NO MW JOINTS 9 f SCH. 40 PVC OUm vflH ZAB1L FILTER Know what's below. Call before you dig. 7.2' PROPOSED SILT PENCE - AID SILTS m AP 25, IAT 301 1fi00 OAIION� SEPDC UNK PROPOSED Di FRADON BOOL - PROPOSED OBSERWIDON PORT (r►: OF 4 AP 25, LOT 299 I■ mi 9 f SCH. 40 PVC OUm vflH ZAB1L FILTER Know what's below. Call before you dig. 7.2' PROPOSED SILT PENCE - AID SILTS m AP 25, IAT 301 1fi00 OAIION� SEPDC UNK PROPOSED Di FRADON BOOL - PROPOSED OBSERWIDON PORT (r►: OF 4 AP 25, LOT 299 N ` /yo imm1 W •d rr •I•I:a AP 25, LOT 303 9.9' HIGH GROUND -WATER LEVEL COMPUTATION FOR it SOUTH WEST DRIVE 6-12' E SAND 5YR 8/1 STEP 1 MEASURE DEPTH TO WATER TABLE TO NEAREST 1/10 FT. DATE 11/14/14 6-17" E SAND 5YR 8/1 8.9 STEP 2 USING WATER -LEVEL RANGE ZONE � �0•� taxa_ � ! / 17-54" B SAND 7YR 5/8 AND INDEX WALL MAP LOCATION 48-120' C SAND IOYR 6/6 0.4 SITE AND DETERMINE: 0.3 CONCRETE BOUND (FOUND TYPICAL) ® APPROPRIATE INDEX WELL W2 GROUNDWATER WEEPING 0 108' 1.30 (() WATER -LEVEL RANGE ZONE SOUTH WEST DRIVE STEP 3 USING MONTHLY REPORT "CURRENT CAPE COD COMMISSION TECHNICAL BULLETIN 92-001 Ile (GRAVEL ROAD) WATER RESOURCES CONDITIONS SOAK _9 BENCHMARK DETERMINE CURRENT DEPTH TO DEPTH HORIZON SOIL TYPE SOIL COLO I ELEV. WATER LEVEL FOR INDEX WELL 11/14 8 I ELEV. STEP 4 USING TABLE OF WATER -LEVEL ADJUSTMENTS EL 10.39 1 FOR INDEX WELL (STEP 2A), CURRENT DEPTH NAVD 1988 TO WATER LEVEL FOR INDEX WELL (STEP 3), AND WATER -LEVEL ZONE (STEP 28) 2° DETERMINE WATER -LEVEL ADJUSTMENT5 SCALE: 1 " = 20' STEP 5 ESTIMATE DEPTH TO HIGH WATER ASSESSORS MAP 25 LOT BY SUBTRACTING THE WATER LEVEL ADJUSTMENT (STEP 4) FROM MEASURED DEPTH TO WATER - FRONT YARD = 30' SIDE YARD = 15 REAR YARD = 20' (CURRENT LEVEL AT SITE (STEP 1) f 6.51 PROFILE OF SYSTEM N ` /yo imm1 W •d rr •I•I:a AP 25, LOT 303 3' JAMES W. NIEVA 39399 FILE COPY GRAPHIC SCALE (INS) 1 INCH - 20 FEET FLIER FABRIC AT IN E 2 LOCATIONS FM 15. % 101 101 101-191 101101 4' SCH 40 PVC WITH 6' CRUSHED STONE 44.3 UT JOINTS LEACHING TRENCHES DISTRIBUTION BOX (ter � �� (NOT TO SINE) TRENCH CONFIGURA110N 2 TRENCHES 44.3' LONG SPACED 12' O.C. CONTAINING 7 CULTEC 180 HD CHAMBERS EACH TRENCH 1' 36' ISPECTIONS REQUIRED OF THE PLEASE NOTIFY DUNN-McKENZIE, INC. (800-540-9720) , AT LEAST 48 HOURS TN ADVANCE 1. SEPTIC TANK EXCAVATION WITH STONE PRIOR TO SEPTIC TANK PLACEMENT. 2. LEACHING FIELD EXCAVATION PRIOR TO BACKFILLING WITH "SEWER GRAVEL". 3. 'SEWER GRAVEL" BACKFILL - MUST PASS SIEVE TEST (SEE NOTE #1 ON SHEET #2 UNDER "SYSTEM IN FILL"). 4. ALL PIPING AND CHAMBER ELEVATIONS PRIOR TO BACKFILL. 5. FILTER FABRIC AND FINAL GRADING OVER ENTIRE SYSTEM. * EXCAVATION NOTE THE ENGINEER MAY ORDER THE REMOVAL OF ADDITIONAL UNSUITABLE SOIL THAT MAY BE ENCOUNTERED UPON INSPECTION OF OPEN EXCAVATION. DATUM NOTE : ELEVATIONS REFER TO THE NATIONAL GEODETIC VERTICAL DATUM - 1988 BENCHMARK NOTE: BENCHMARK SHALL BE SET WITHIN 50 FT. OF LEACHING SYSTEM PRIOR TO ANY CONSTRUCTION. REMOVE THESE SOIL HORIZONS SEE 'LEACHING FIELD' NOTE 6 ON SHEET 2 SOIL TEST RESULTS TEST HOLE: 14-1 11-14-14 GROUND ELEV.= 10.4 ST HOLE: 14-2 DATE: 11-14-14 GROUND M= 10.3 DEPTH HORIZON SOIL TYPE SOIL. COLO I ELEV. rDEPTH HORIZON SOIL TYPE SOIL COLORI ELEV. LOAM/ WR 7/8' 9.9' 2-6"/ / A /SANDY LRAM/ 7YR 7/8/ 6-12' E SAND 5YR 8/1 9.4 6-17" E SAND 5YR 8/1 8.9 12-48' B SAND 7YR 5/8 � �0•� taxa_ � ! / 17-54" B SAND 7YR 5/8 5.8 48-120' C SAND IOYR 6/6 0.4 54-120' C SAND 10YR 6/6 0.3 CONCRETE BOUND (FOUND TYPICAL) 11155T GROUNDWATER WEEPING 0 108' 1.30 GROUNDWATER ELEV. (2.50 FRIMPTER ADJUSTMENT) SOUTH WEST DRIVE 1 3.80 CAPE COD COMMISSION TECHNICAL BULLETIN 92-001 Ile (GRAVEL ROAD) CAPE COD COMMISSION TECHNICAL BULLETIN 92-001 SOAK _9 BENCHMARK TEST HOLE DATE GROUND ELEV.= DEPTH HORIZON SOIL TYPE SOIL COLO I ELEV. TOP OF CONCRETE BOUND I ELEV. 12" EL 10.39 1 12" NAVD 1988 Ila SITE PLAN 2° SCALE: 1 " = 20' 11" ASSESSORS MAP 25 LOT 302 ZONING REFERENCE R-25 BUILDING SETBACK - FRONT YARD = 30' SIDE YARD = 15 REAR YARD = 20' (CURRENT ZONING) PROFILE OF SYSTEM 9' 1:39 (Or 70 3r"AlE) ' YV1WW OF COVER 9" 3 CO OBSERVATION PIPE man OF 36" VER g' OVER SY51E11 ( FYUSH GRAD, t PER TRENCH 6' fR011 EkOSt1 GRADE GRASS SIINFACE MAGILBC TAPING SEE CONSTRUCTION NOTE 7 ON SHEEP 2 MIN. FG.=124 _17.T. 2X NVtlYIlW SLOPE 8" 1 I I- -. 7" MAGNETIC TAPING 3' JAMES W. NIEVA 39399 FILE COPY GRAPHIC SCALE (INS) 1 INCH - 20 FEET FLIER FABRIC AT IN E 2 LOCATIONS FM 15. % 101 101 101-191 101101 4' SCH 40 PVC WITH 6' CRUSHED STONE 44.3 UT JOINTS LEACHING TRENCHES DISTRIBUTION BOX (ter � �� (NOT TO SINE) TRENCH CONFIGURA110N 2 TRENCHES 44.3' LONG SPACED 12' O.C. CONTAINING 7 CULTEC 180 HD CHAMBERS EACH TRENCH 1' 36' ISPECTIONS REQUIRED OF THE PLEASE NOTIFY DUNN-McKENZIE, INC. (800-540-9720) , AT LEAST 48 HOURS TN ADVANCE 1. SEPTIC TANK EXCAVATION WITH STONE PRIOR TO SEPTIC TANK PLACEMENT. 2. LEACHING FIELD EXCAVATION PRIOR TO BACKFILLING WITH "SEWER GRAVEL". 3. 'SEWER GRAVEL" BACKFILL - MUST PASS SIEVE TEST (SEE NOTE #1 ON SHEET #2 UNDER "SYSTEM IN FILL"). 4. ALL PIPING AND CHAMBER ELEVATIONS PRIOR TO BACKFILL. 5. FILTER FABRIC AND FINAL GRADING OVER ENTIRE SYSTEM. * EXCAVATION NOTE THE ENGINEER MAY ORDER THE REMOVAL OF ADDITIONAL UNSUITABLE SOIL THAT MAY BE ENCOUNTERED UPON INSPECTION OF OPEN EXCAVATION. DATUM NOTE : ELEVATIONS REFER TO THE NATIONAL GEODETIC VERTICAL DATUM - 1988 BENCHMARK NOTE: BENCHMARK SHALL BE SET WITHIN 50 FT. OF LEACHING SYSTEM PRIOR TO ANY CONSTRUCTION. REMOVE THESE SOIL HORIZONS SEE 'LEACHING FIELD' NOTE 6 ON SHEET 2 SOIL TEST RESULTS TEST HOLE: 14-1 11-14-14 GROUND ELEV.= 10.4 ST HOLE: 14-2 DATE: 11-14-14 GROUND M= 10.3 DEPTH HORIZON SOIL TYPE SOIL. COLO I ELEV. rDEPTH HORIZON SOIL TYPE SOIL COLORI ELEV. LOAM/ WR 7/8' 9.9' 2-6"/ / A /SANDY LRAM/ 7YR 7/8/ 6-12' E SAND 5YR 8/1 9.4 6-17" E SAND 5YR 8/1 8.9 12-48' B SAND 7YR 5/8 6.4 17-54" B SAND 7YR 5/8 5.8 48-120' C SAND IOYR 6/6 0.4 54-120' C SAND 10YR 6/6 0.3 GROUNDWATER WEEPING 0 110' 1.23 GROUNDWATER WEEPING 0 108' 1.30 GROUNDWATER ELEV. (2.50 FRIMPTER ADJUSTMENT) 3.73 GROUNDWATER ELEV. (2.5' FRIMPTER ADJUSTMENT) 1 3.80 CAPE COD COMMISSION TECHNICAL BULLETIN 92-001 SOAK CAPE COD COMMISSION TECHNICAL BULLETIN 92-001 SOAK TEST HOLE DATE GROUND ELEV.= TEST HOLE DATE GROUND ELEV.= DEPTH HORIZON SOIL TYPE SOIL COLO I ELEV. DEPTH HORIZON SOIL TYP SOIL COLOR I ELEV. SOIL EVALUATOR: JAMES W. NIEVA, PLS, C.S.E. staffrMA I B.O.H. AGENT: AMY L vonHONE, R.S., C.H.O. PERCOLATION TESTS TEST NO.: 14-2 DB= 10.3 TEST NO.: ELEV.= TEST NO.: a"= TEST NO.: ELEV.= DATUM TIME INTERN DATUM TIME JINTERVAL DATUM TIME INTERVAL DATUM TIME TRERV) SOAK 1:22 - 1:37 SOAK SOAK SOAK 12' 1.37 12" 12" 1 12" Ila 11"11" 11" 10' 10' 10' 10" 9' 1:39 9" 9" g' 8' 8' 8" 8" 7" 7" 7" 7" 6" 1 1:41 6' 6" 6" RATE: <2 MPI RATE: RATE: RATE: DATE 11-14-14 DATE: DATE: DATE: DEPTH: 36" DEPTH: DEPTH: DEPTH: CERTIFY THAT ON JULY 1, 2010, 1 HAVE PASSED THE EXAMINATION APPROVED BY THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND THAT THE ABOVE ANALYSIS HAS BEEN PERFORMED CONSISTENT WITH THE REQUIRED TRAINING, EXPERTISE, EXPERIENCE DESCRIBED IN 310CMR 15.018(2). JAMES W. NIEVA, PLS, SOIL EVALUATOR SE#13258 TITLE 5 SEWAGE DISPOSAL SYSTEM FOR A PROPOSED 5 BEDROOM DWELLING LOCATION TO C 11 SOUTH WEST DRIVE YARMOUTH, MA 02601 APPLICANT RECORD OWNER: S.L. BENOIT GEORGE & JANA TARASENKO 206 DEDHAM STREET 87 PATRICKS RUN NORFOLK, MA 02056 STOUGHTON, MA 02072 508-889-5992 J Dunn • McKenzie Inc. n.E 5 SM SAND LAND SURVEYING AND CIVIL ENGINEERING 206 DEDHAM STREET, Rt.1A at Rt.115 NORFOLK, MASSACHUSETTS 02056 (508) 384-3990 - FAX (508) 384-3905 email 11 enzle.com TRENCH CROSS SECTION unnmc (Nor 70ST w DATE: JANUARY 16, 2015 1 SHEET 1 OF 2 1 JOB NO. 5221