HomeMy WebLinkAbout17 Spinnaker Lane - Site & Sewage Plan1 SEPTIC PROFILE T.O.F. AT EL. 35.0'NOT To SCALE) ACCESS COVER TO WITHIN 6" OF FIN. GRADE ( ACCESS COVER (WATERTIGHT) TO 34'0' MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE 31,0' FOR FIRST 2' PROPOSED 1500;--4f GALLON SEPTIC 30.02' .30.27' TANK (H- 10 ) GAS EL BAFFLE 30.01j/ -2 4 (z7 SLOPE) �_6" CRUSHED STONE OR MECHANICAL o COMPACTION. (15.221 [21) - og DEPTH F FLOW = 4 ( % SLOPE) ( % SLOPE) TEE SIZES: INLET DEPTH OUTLEIT DEPTH = 14" FOUNDATION- 35' - SEPTIC TANK 1 D' BOX WELLS: (ON BORDER BETWEEN SDW 252 AND AIW 247) ZONE: B ADJUSTMENT: AIW 247 (NOV.) - 2.7' SDW 252 (NOV) - 2.3' AIW 247 (DEC) - 3.1' SDW 252 (DEC) - 2.6' USE AVERAGE BETWEEN WELLS AND BETWEEN MONTHS (MONITORING WELL READING WAS TAKEN DECEMBER 16, 1998) = 2.7' ADJUSTMENT TEST HOLE -LOGS I ENGINEER; A.H. OJALA, PE 2% SLOPE REQUIRED OVER SYSTEM310' WITNESS; AMY VON HONE, RS M BRUCE MURPHY, RS . DATE: 12/9/98 / 2" DOUBLE WASHED PEASTONE I < 2 MIN/INCH \ 3' MAX. PERC. RATE _ CLASS I & III SOILS P# ---------- 3/4" To 1 1/2" DOUBLE WASHED STONE A MW 0" 1_I LEACHING FACILITY 5' USE ADJ. WATER ® 24.2' 72„ MW SET 12/9/98 MW LEVELED AND / MEASURED 12/16/98 4 B LS 12" Cl 36" SILT LOAM C2 FINE SAND 72" obs. water ELEV. Q 27.51' 0" - B LS 10" 2.5Y 6/6 - Cl SILT LOAM 3011 2.5Y 6/2 24.51' 2814' 27.31. ASSESSORS MAP 103 PARCEL 63 ZONING DISTRICT R40 (CURRENT) C2„ YARD SETBACKS: 63"� FRONT = FINE SAND SIDE _ REAR = 2.5Y 7/6 PLAN REF. - 96/1331 (1965) TO 2.5Y 6/3 FLOOD ZONE: C __ -- 3p 50 p0 \� f R LANE (et. 23.64') E 114" 18.01' 120" 18.14' C. BAST E - CTR 1 NOTES: SPIN NA j{ 132� C. BASIN EL = 2s.ei r NO WATER -32 6 %/ 133 X5L;23 /29_ \ y '`0 �� TH3 27.85' SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED - _ R=1 " 61 / CESIGN FLOW: 3_ BEDROOMS (110 GPD) = 330 GPD Ih; S. �O USE A �J6 GPD DES;GN F LOV: J/ 2 / SEPTIC TANK: 330 GPD ( 2 ) = 660 (/ 1��12i1 c + I102.1/L / / ` -29- o 1 USE A 1500_ GALLON SEPTIC TANK 1 1 / 32.0' 1 O q 0° `'� 32.0' 2 1 LEACHING: t N/A 10 ; SIDES: '`33- - �� 33.0' / 0 15 x 30 (.74) = 333 � \ \ _� -., � BOTTOM: _ r 9 \ 3p--- 34.0' 33.0' ? �1 1 / U,l .TOTAL: 450 S.F. 333 GPD ��1 �2g� , 11• 1 /" R = V, 1 o USE 2 ROWS OF 4 STANDARD INFILTRATORS EACH WITH 6R 0�1/ 0 3' STONE BETWEEN ROWS AND AT SIDES, 2.5' AT ENDS 1PP-OP 3 1 s 1 LOT 3 p -OP 1"G 0 11 GAR v EL. 29.09' /` �2 TH1 TF: 3L 35. �- - 10,4Lf 7 sq. ft. TH2 , /1� ? o 0.174 ac. I \\ 11 I ® BN �`sa.o' 5 `� 30 LEGEND PROP. PATIO Ii 31 _ - - 10' - - _ 100.0 PROPOSED SPOT ELEVATION - -, __31---- - 20' 100xO EXISTING SPOT ELEVATION 140 p0 �'�-� - - - - - - - - --- - - - - 100 _ PROPOSED CONTOUR _ - - - s ' - _ - - - - - - -- - 100 - - EXISTING CONTOUR ---------------------�- 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF SYSTEM DOWN TO FINE SAND LAYER. REPLACE WITH CLEAN MED. SAND. ENGINEER TO INSPECT AND CERTIFY REMOVAL. 98-413 BOARD OF HEALTH _) 1. DATUM JS APPROXIMATED FROM DENNIS QUAD 2, MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1Z8" PER FOOT. 4, DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. III i srTE AND SEWAGE PLAN OF LOT 3 SPINNAKER LANE IN THE TOWN OF: YARMOUTH( iIORT) PREPARED FOR: DUBLIN CONSTRUCTION 20 0 20 40 60 -+ MA SCALE: 1.. = 20' DATE: DECEMBER 15 1998 'APPROVED DATE o4 508-362-4541. fm 508 362-9880 1OH JOF Of 411gdown cape engineering, inc. ARNE ARNE4AH. � III CIVIL ENGINEERS s o1HAiA 8 CIVIL ti No. 28348. ,. No. LAND SURVEYORS 9�"�ss aF f1 c> -�1---- 939 main st. yarmouth, ma 02675_ A H. A, -PA7E II i RTE. 6A.. C G p 2 PO P� Y V Q OCK O C: ) MID EX T LOCUS, MAP SCALE ''I 1" = 2083' 27.31. ASSESSORS MAP 103 PARCEL 63 ZONING DISTRICT R40 (CURRENT) C2„ YARD SETBACKS: 63"� FRONT = FINE SAND SIDE _ REAR = 2.5Y 7/6 PLAN REF. - 96/1331 (1965) TO 2.5Y 6/3 FLOOD ZONE: C __ -- 3p 50 p0 \� f R LANE (et. 23.64') E 114" 18.01' 120" 18.14' C. BAST E - CTR 1 NOTES: SPIN NA j{ 132� C. BASIN EL = 2s.ei r NO WATER -32 6 %/ 133 X5L;23 /29_ \ y '`0 �� TH3 27.85' SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED - _ R=1 " 61 / CESIGN FLOW: 3_ BEDROOMS (110 GPD) = 330 GPD Ih; S. �O USE A �J6 GPD DES;GN F LOV: J/ 2 / SEPTIC TANK: 330 GPD ( 2 ) = 660 (/ 1��12i1 c + I102.1/L / / ` -29- o 1 USE A 1500_ GALLON SEPTIC TANK 1 1 / 32.0' 1 O q 0° `'� 32.0' 2 1 LEACHING: t N/A 10 ; SIDES: '`33- - �� 33.0' / 0 15 x 30 (.74) = 333 � \ \ _� -., � BOTTOM: _ r 9 \ 3p--- 34.0' 33.0' ? �1 1 / U,l .TOTAL: 450 S.F. 333 GPD ��1 �2g� , 11• 1 /" R = V, 1 o USE 2 ROWS OF 4 STANDARD INFILTRATORS EACH WITH 6R 0�1/ 0 3' STONE BETWEEN ROWS AND AT SIDES, 2.5' AT ENDS 1PP-OP 3 1 s 1 LOT 3 p -OP 1"G 0 11 GAR v EL. 29.09' /` �2 TH1 TF: 3L 35. �- - 10,4Lf 7 sq. ft. TH2 , /1� ? o 0.174 ac. I \\ 11 I ® BN �`sa.o' 5 `� 30 LEGEND PROP. PATIO Ii 31 _ - - 10' - - _ 100.0 PROPOSED SPOT ELEVATION - -, __31---- - 20' 100xO EXISTING SPOT ELEVATION 140 p0 �'�-� - - - - - - - - --- - - - - 100 _ PROPOSED CONTOUR _ - - - s ' - _ - - - - - - -- - 100 - - EXISTING CONTOUR ---------------------�- 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF SYSTEM DOWN TO FINE SAND LAYER. REPLACE WITH CLEAN MED. SAND. ENGINEER TO INSPECT AND CERTIFY REMOVAL. 98-413 BOARD OF HEALTH _) 1. DATUM JS APPROXIMATED FROM DENNIS QUAD 2, MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1Z8" PER FOOT. 4, DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. III i srTE AND SEWAGE PLAN OF LOT 3 SPINNAKER LANE IN THE TOWN OF: YARMOUTH( iIORT) PREPARED FOR: DUBLIN CONSTRUCTION 20 0 20 40 60 -+ MA SCALE: 1.. = 20' DATE: DECEMBER 15 1998 'APPROVED DATE o4 508-362-4541. fm 508 362-9880 1OH JOF Of 411gdown cape engineering, inc. ARNE ARNE4AH. � III CIVIL ENGINEERS s o1HAiA 8 CIVIL ti No. 28348. ,. No. LAND SURVEYORS 9�"�ss aF f1 c> -�1---- 939 main st. yarmouth, ma 02675_ A H. A, -PA7E II i