Loading...
HomeMy WebLinkAbout114 Springer Lane - Septic System Design9' MINIMUM. ///_3' MAXIMUM COVER MIN 2' OF PEASTONE 3/4' - I I/2' DIA. __�DOUBLE WASHED STONE w, �J.O r BAFF'E- 3 OUTLET 6 STANDARD INFILTRATOR D -BOX CHAMBERS W/4't STONE AROUND 1500 GAL I 1 ' • x 50 ' 1 x 7'd SEPTIC TANK 6' CRUSHED STONE OR COMPACTED BASE PROFI LE:NOT TO SCALE INVERT ELEVATIONS: TP •l TEXTURE DESIGN CRITERIA: INVERT AT BUILDING: 99.9 DESIGN FLOW: INVERT 1N SEPTIC TANK: 99.15 4 BEDROOMS AT 110 G.P.D. PER INVERT OUT SEPTIC TANK: 98.9 BEDROOM EQUALS 440 G.P.D. INVERT IN DIST. BOX: 98.77 98.6 NO GARBAGE GRINDER INVERT OUT DIST. BOX: INVERT IN LEACH CHAMBER: 98.56 SEPTIC TANK REOUIRED:, BOTTOM OF LEACH CHAMBER: 98.0 440 G.P.D. X 200x - 860 GAL. ADJUSTED GROUND WATER: 93.0 SEPTIC TANK PROVIDED: 1500 GAL. MIN. OBSERVED GROUND WATER: 91.1 BOTTOM OF TEST HOLE *1: 89.6 SOIL ABSORPTION SYSTEM REQUIRED.- EQUIRED.INDEX INDEXWELL MIW 29. ZONE B DESIGN PERC RATE f 5 MIN/INCH DEC 04 READING -8.6% ADJ-2.9' SOIL TEXTURAL CLASS - I USE A 7.9' ADJUSTMENT FOR DESIGN EFFLUENT LOADING RATE - 0.74 GPD/SF 440 GPD / 0.74 GPD/SF - 595 S.F. REQUIRED PROVIDED: 6 STANDARD INFILTRATOR T CHAMBERS W/4's STONE AROUND, A-621 S.F. 1 V 621 S.F. x 0.74 - 459 GPD SOIL TEST PIT DA TA e INDICATES V INDICATES PERCOLATION = OBSERVED TEST _ GROUNDWATER HORIZON TP •l TEXTURE COLOR 0' A LOAMY IOYR. SAND 3/2 5' ...................... ................ B LOAMY IOYR SAND........... 4/6... 22' . C MEDIUM I0YR SAND 6/4 44' 3m 99.2 GENERAL NOTES; 1. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET, SEE SITE PLAN. 3. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS.' 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL, 6. SEPTIC TANK AND 0 -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D -BOX SHALL BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. EXISTING CESSPOOLS TO BE PUMPED DRY. REMOVED IN THE AREA OF THE NEW SYSTEM AND BACKFILLED WITH CLEAN SAND. 97.8 9, EXISTING INVERT AT THE DWELLING TO BE RELOCATE 120'1 1 89.6 DATE: DECEMBER 8. 2004 TEST BY: STEPHEN HAAS - WITNESSED BY: DAVID FLAHERTY PERC RATE: ( 2 MIN/INCH a TO TH£wLOCATION AND ELEVATION SHOWN. 10. ALL UNSUITABLE MATERIAL JA 4 8 HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. Il. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS, VARIANCES ETC. FOR THIS PROJECT. 12. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING.