Loading...
HomeMy WebLinkAbout59 Squirrel Run - Site Plan 3�-LIN � SYSTEM PRD�ILE TODPVFNDN. AT EL. 26.6' ACCESS COVER TO WITHIN 6' OF FIN. GRADE (NOT TO SCALE) T� ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST r WITHIN 6. OF FIN. GRADE 2% SLOPE RUN PIPE LEVEL 24.85'-4 FOR FIRST 2' I 1 PIOPOSED�..`Q0 EXISTING LEACH PITS (RE -USE) GALLON SEPTIC 24.40' - 2-4-65/T'TANK <H- 10) GAS ��s 24.13' INVERTS = 23.6't AND 23.9't (SNOTE BAFFLE 24.30' �� 11,) ( 2 7. SLOPE)~ �6' CRUSHED STONE OR MEHANICAL j COMPACTION. (15.221 123) MIN DEPTH OF FLOW = 4 < 1 % SLOPE) (-% % SLOPE) TEE SIZES, INLET DEPTH = 10 OUTLET DEPTH - 14 FOUNDATION- 10' - SEPTIC TANK- 10' D' BOX 20 ^.L9.5 /R.5 [RED OVER SYSTEM ?.9 `i yy� PROP. 1500 GAL. �� 4•Y f SEPTIC TANK 1/ (PUMP AND REMOVE EXISTING I SEPTIC TANK) l PROP. O'BOX EXIST. ��, LP LP I (RETAIN) CONC., ONC RfT -ALL' _y + 295 :PEN j y 7- 'm 94 M 33.C,` I is v TENNIS COURT / 41 � AWN u 190. a2 %ISL LP RETAIN)' ,tel 26.8 V 1- 26.5 + 29.7 / /PROP. 1500`,GAL. PROP SEPTIC TANK,, ADDITION EXIST GARAGE + 34.3 BENCHMARK: USE TOP FNDN AT ELEV. 26.6' LEA,` -4. NG FAC,1_ITY GARAGE 'I PROPOSED1500 29 75' GALLON SEP -'IC TANK (H- 10 ) 6' CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) PROP. MASTER BEDROOM _ EXPANSION DWELLING: x\x SEPTIC DESIGN; (GARBAGE DISPOSER IS NOT ALLOWED ) DESIGN FLOW 3 13_ -DOOMS (10 GSD) 33.0 GPD 12. 11 fix\ USE A 330 SPD DESIGN FLOW Ns x 4.9 SEPTIC TAN :330 C?D ( 2 ) = 660 USE A 1500 GALLOP' SEPTIC TA'JK 26.6 ---- k EXIST. DWELL. 6 / '1. k 'ARAGE 26.3 � 26.0 N. . SEPTIC DESI5111 (GARPAC- DISPOSER S NOT ALLG-� D ) 26.4 y - - -- 26.4 q - --- -_ 'iESIGN FLOG`. BE JE ]+OMS (1 C C."^) 22 SPI Dz6� 26.3+26.4 % E A 220_(-Dn r� _,: -i.nW P 171 TANK 22U GPD , 2 ) = 440 A 1500 GALLON SEPTIC TANK t9+ 4 4 1 ig8.2 / EXISTING 4 >az 28.6 LEACHING+ a, k I SIDES 81 6 (2.5) - 376 P, 421�'1•� W � APPROX. WATERLINE # BOTTOM: y 50 / LCCATION (UNMARKED) ass / 426 GPD 9o.a 6 L7 "lip r T SIDES 161(t( 1%2.5) 565 ) 13 BOTTOM: -- 3�r32` 13 Z0.7678 SPD sl 7 X0.8 + 3t r 5IR;5 30'7 TOTAL: 1104 GPD .ME J I WATER`SHUT-OFF.,? + NOTE. NO 4 TER FOUND TO ELEVATION 11.2' PER TROY WILLIAMS, DEP SEPTIC INSPECTOR ON 8/17/01. ('HIS ELEVATION IS 7' BELOW THE BASE OF THE LEACH PIT ) + STONE %f ! LOT AREA 1 \ -�. _ _ ' 58,8641 M, FT. DRIVE _ _ 1 \ �3 u - - u 34 '.9`- ' 3A + as I_ 35 I BOARD OF HEALTH I + + + 32.6 ,-- 91.9348 34.2 ._-36 .._....?c ;� JS.� 35 _ MA r87 + 351 � APPROVED DAT:: 35.5 . fr .4 ._ 01-1'74 . 370/ -_J6 n2>: Fox 509 362-%Og 37.5 ''�.�� / I ''SS'•.. BENCH MARK - CTR OF DOUBLE ` L=31.42' 30.7 4 C. BASINS EL. = 34.3' (F.SSMD) clown Cape engineering, Lnc, 20.00 �a8 / C VIL ENGINEERS A.7 I '` 33 LAND SURVEYORS 939 chin s':. yar-iouth, Ina C2675 LOCATION MAP NTS ASSESSORS MAP 123 PARCEL 82 ZONING DISTRICT: R40 YARD SETBACKS+ FRONT = 30' SIDE = 20' REAR = 20' PLAN REF, - 322/59 FLOOD ZONE: C NOTES: 1. DATUM IS APPROX. FROM QUAD 2, MUNICIPAL WATER 1SEXISTING 3. MINIMUM PIPE PITCH TO BE 1/8' PER FOOT. L CTAiiir:^:, FOR ALL Pr�LCAST UIJITS T❑ BE AASHO H-10 . 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS, ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH, 40-4' PVC. 9, COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR TO NOTIFY DIG -SAFE AND WATER DEPT. 11. CONTRACTOR TO CONFI M INVERT ELEVATIONS TO LEACH PITS PRIOR TO INSTALLATION OF ANY PORTION OF SYSTEM * ASSUMED MIN. 1' STONE AROUND PIT Y/+R1. Qxrno '^^;,-rEE SITE �h.. OF 59 SQUIRREL RUN` IN THE TOWN OF: YARMOUTH PORT PREPARED FOR: D. K U S H N E R 20 0 20 40 60 cI-- ALE' 1" = 30' DATE: SEPT. 7, 2001 OF ARNF H.C�G_ ���LIARNE'�J'��. �r� 0 / DATE