Loading...
HomeMy WebLinkAbout210 Station Avenue Schedule and Detailsi SPP" ­r , 4'X4' PLYWOOD BACKBOARD SEE NOTE 3. 3 KVA FOR TELEPHONE, DATA, FIRE ALARM SPI AND SECURITY SERVICES TO BUILDING. SP1 -7 EF SP1 -9 SEE NOTES 1 & 2. - - _ tt NOTES: // U SP1 -8 T SP1 -6— —_ — SP1 -5 S — �S — SP( -6 - SP1 -10 SPP -7 10� SPP 2 15 /3P 15A/3P 1. STUB—UP CONDUITS FOR TELEPHONE, DATA, FIRE ALARM, AND SECURITY SERVICES. REFER TO SITE /// d SPP —1 5A/3P 3#12+#92 1/2"C I PLANS FOR NUMBER AND TYPE OF CONDUITS. REFER TO DWGS E7.06 AND E7.07 FOR fUH ® taes 3#1 +#12G, 1/2"C // i i 15A/3P O 3# 12+# 12G, 1 /2"C ® EUH EUH p VOICE AND DATA CABLING REQUIREMENTS. EXTEND ALL CABLING FOR FIRE ALARM DEVICES ;� �13e 3#12+#12iG, 1/2"C 0 FO ® EUH BACK TO FACP IN MAIN BUILDING IN CONDUITS) DEDICATED FOR FIRE ALARM CABLING. PROVIDE 6 t� t _ tom, I t� t t© FIRE ALARM TERMINAL CABINET OR EXTENDER PANEL IF REQUIRED. EXTEND CABLING FOR �0 SECURITY DEVICES SACK TO SECURITY CONTROL PANEL IN MAIN BUILDING AND PROVIDE INTERMEDIATE, CONTROLLER(S) OR EXTENDER PANEL IF REQUIRED. CONNECT ANY NEEDED FIRE ALARM &SECURITY EQUIPMENT TO SP1 -8. - ---- 2. 2, 2"C TO WASTE WATER TREATMENT PLANT. i SEE NOTE 4, i 3. TIME CLOCK FOR EXTERIOR LIGHTS. 6 TYP. FOR 8 EUH'S g SPP -3 EUH SPP -5 f SPP -8 taa 15A/3P SPP -4 15A/3P (15A/3P 10�j` 4. PROVIDE 7.5KW, 480V, 34 ELECTRIC UNIT HEATERS EQUAL TO QMARK MUH-07-4 WITH UNIVERSAL _ O 3#12+#1 G, 1/2'1 QF 15A/3P ® O 3#12+#12 1/2"C QF 03#12+#12p,1 2"C © CEILING MOUNTING BRACKET, CONTROL TRANSFORMER, AND THERMOSTAT. PROVIDE ALL CONTROL WIRING t� / BETWEEN CONTROL TRANSFORMER AND THERMOSTAT FOR OPERATION. �j SPp-1_ P1+2 t t I t� t� t� El 1 - SP1 3 SP1 -111 SP1 -12 j SP1 -13 p 5. INSTALL GROUND ROD OUTSIDE OF STORAGE BUILDING, 2 FEET BELOW GRADE, EUH ~� SP11-14� El 6 _ � SP1 -4 „�71�__ PROVIDE #2 GROUNDING ELECTRODE CONDUCTOR. PROVIDE SEPARATE - - - - - _ _ _ _ - � 5 X Ii _ 5 �` I `a GROUNDING ELECTRODE CONDUCTORS TO BUILDING STEEL. - - _ OH OH OH -0 f = -... - 6. PANEL SPP SHALL BE SERVICE ENTRANCE RATED. CONNECTION FOR ERHEAD OOR. - - ! OH I 6IINSTALL CONTROL ST I BY DIV 8 AND PROVIDE INTERCONNECTION 1 iNo ETWEEN CONTROL STATION AND :._..._-._._._J;—_.._..................t. (IR MAN. REQUIREMENTS, TYP. OR ALL 0 ERHEAD DOORS. 1 i...,) i will I CONNECT TO LINE SIDE OF 1;7 "pJ ?.; SWITCH, TYP. I jl F1 F1 �_®__i i --• -; F1�--- - •--i F1 F1 F1 F1 ' F1 t -- j 5 5 { 5 —t i--®---1 = 5 5 5 I SPP- 5 t m I E s.. (4)#3, 1#8G, 1 -1 /4"C,4 i O#6, 1#tOG, 1"C, 30KVA F1 F1 F1 c ��"1 --� r —•--I r_• F1 f F1 i --X { 5 5 I 5 5 5 5 i �—'�_ l �_•_� Yi 5 6!5 1 SPP16 CONNECT THROUGH; TC I All f € SEE6 NOTE 3 .. # = EB 5� 5�- - - _ __.:_ s. - SP1 SPP SL S -z 6�S 6�5. 6�S VS 6 277/480VT,, Pr 7jj 120/208V NOTE 5 DP13, ELEC RM 344. REFER TO DWG. EO.03 FOR FEEDER ROUTING. 7 10OA/3P CIRCUIT BREAKER (4)#3/0, 1#6G, 2 1/2"C IN PANEL DP13 SHALL BE AND 1 SPARE 2 1/2"C. REVISED TO 150A/3P C.B. P WER ON - N DIAGRAM El 1 SCALE: N.T.S. NOTE 6 SCHEDULE OF PANELBOARDS SPP" ­r , 4'X4' PLYWOOD BACKBOARD SEE NOTE 3. 3 KVA FOR TELEPHONE, DATA, FIRE ALARM SPI AND SECURITY SERVICES TO BUILDING. SP1 -7 EF SP1 -9 SEE NOTES 1 & 2. - - _ tt NOTES: // U SP1 -8 T SP1 -6— —_ — SP1 -5 S — �S — SP( -6 - SP1 -10 SPP -7 10� SPP 2 15 /3P 15A/3P 1. STUB—UP CONDUITS FOR TELEPHONE, DATA, FIRE ALARM, AND SECURITY SERVICES. REFER TO SITE /// d SPP —1 5A/3P 3#12+#92 1/2"C I PLANS FOR NUMBER AND TYPE OF CONDUITS. REFER TO DWGS E7.06 AND E7.07 FOR fUH ® taes 3#1 +#12G, 1/2"C // i i 15A/3P O 3# 12+# 12G, 1 /2"C ® EUH EUH p VOICE AND DATA CABLING REQUIREMENTS. EXTEND ALL CABLING FOR FIRE ALARM DEVICES ;� �13e 3#12+#12iG, 1/2"C 0 FO ® EUH BACK TO FACP IN MAIN BUILDING IN CONDUITS) DEDICATED FOR FIRE ALARM CABLING. PROVIDE 6 t� t _ tom, I t� t t© FIRE ALARM TERMINAL CABINET OR EXTENDER PANEL IF REQUIRED. EXTEND CABLING FOR �0 SECURITY DEVICES SACK TO SECURITY CONTROL PANEL IN MAIN BUILDING AND PROVIDE INTERMEDIATE, CONTROLLER(S) OR EXTENDER PANEL IF REQUIRED. CONNECT ANY NEEDED FIRE ALARM &SECURITY EQUIPMENT TO SP1 -8. - ---- 2. 2, 2"C TO WASTE WATER TREATMENT PLANT. i SEE NOTE 4, i 3. TIME CLOCK FOR EXTERIOR LIGHTS. 6 TYP. FOR 8 EUH'S g SPP -3 EUH SPP -5 f SPP -8 taa 15A/3P SPP -4 15A/3P (15A/3P 10�j` 4. PROVIDE 7.5KW, 480V, 34 ELECTRIC UNIT HEATERS EQUAL TO QMARK MUH-07-4 WITH UNIVERSAL _ O 3#12+#1 G, 1/2'1 QF 15A/3P ® O 3#12+#12 1/2"C QF 03#12+#12p,1 2"C © CEILING MOUNTING BRACKET, CONTROL TRANSFORMER, AND THERMOSTAT. PROVIDE ALL CONTROL WIRING t� / BETWEEN CONTROL TRANSFORMER AND THERMOSTAT FOR OPERATION. �j SPp-1_ P1+2 t t I t� t� t� El 1 - SP1 3 SP1 -111 SP1 -12 j SP1 -13 p 5. INSTALL GROUND ROD OUTSIDE OF STORAGE BUILDING, 2 FEET BELOW GRADE, EUH ~� SP11-14� El 6 _ � SP1 -4 „�71�__ PROVIDE #2 GROUNDING ELECTRODE CONDUCTOR. PROVIDE SEPARATE - - - - - _ _ _ _ - � 5 X Ii _ 5 �` I `a GROUNDING ELECTRODE CONDUCTORS TO BUILDING STEEL. - - _ OH OH OH -0 f = -... - 6. PANEL SPP SHALL BE SERVICE ENTRANCE RATED. CONNECTION FOR ERHEAD OOR. - - ! OH I 6IINSTALL CONTROL ST I BY DIV 8 AND PROVIDE INTERCONNECTION 1 iNo ETWEEN CONTROL STATION AND :._..._-._._._J;—_.._..................t. (IR MAN. REQUIREMENTS, TYP. OR ALL 0 ERHEAD DOORS. 1 i...,) i will I CONNECT TO LINE SIDE OF 1;7 "pJ ?.; SWITCH, TYP. I jl F1 F1 �_®__i i --• -; F1�--- - •--i F1 F1 F1 F1 ' F1 t -- j 5 5 { 5 —t i--®---1 = 5 5 5 I SPP- 5 t m I E s.. (4)#3, 1#8G, 1 -1 /4"C,4 i O#6, 1#tOG, 1"C, 30KVA F1 F1 F1 c ��"1 --� r —•--I r_• F1 f F1 i --X { 5 5 I 5 5 5 5 i �—'�_ l �_•_� Yi 5 6!5 1 SPP16 CONNECT THROUGH; TC I All f € SEE6 NOTE 3 .. # = EB 5� 5�- - - _ __.:_ s. - SP1 SPP SL S -z 6�S 6�5. 6�S VS 6 277/480VT,, Pr 7jj 120/208V NOTE 5 DP13, ELEC RM 344. REFER TO DWG. EO.03 FOR FEEDER ROUTING. 7 10OA/3P CIRCUIT BREAKER (4)#3/0, 1#6G, 2 1/2"C IN PANEL DP13 SHALL BE AND 1 SPARE 2 1/2"C. REVISED TO 150A/3P C.B. P WER ON - N DIAGRAM El 1 SCALE: N.T.S. NOTE 6 Uz qpqp-Wd AM LL WORK ON THIS SHFFT I,� Al TFRNIATF- 6 SCHEDULE OF PANELBOARDS PANEL MOUNTING VOLTAGE MAINS TYPE SIZE 15/1 20/1 30/1 ACTIVE CIRCUIT BREAKERS 20/2 25/2 35/2 60/2 15/3 20/3 25/3 60/3 SPARE 20A/1P TOTAL SPACE POLES S.C.I. RATING SP1 SURFACE 208/12OV, 30, 4W MCB 1 18 1 1 6 2 30 10K SPP SURFACE I 480/277V, 30, 4W MCgn 150A 2 If 8 1 3 10 42 14K Uz qpqp-Wd AM LL WORK ON THIS SHFFT I,� Al TFRNIATF- 6