Loading...
HomeMy WebLinkAbout210 Station Avenue Exterior Racking Structure-13N J M i B *TYP 2 S1.5 0 L-3 1 j Fa SUPPORT TRIANGLE SCALE 1 :15 NO. DRAWN: CHECKED: REVIEWED: APPF OVED: 0 BushBr 2127/2013 New 1 BushBrA1312013 IncrE 2 OskeTi 4110/2013 Addl 4 5 6 REVISIONS: DETAIL B SCALE 1 :5 DETAIL C SCALE 1 :5 PARTS LIST GIRDER TABLE QTY ID DESCRIPTION CONFIGURATION 4 NUMBER OF GIRDER ASSEMBLIES 4 GT GIRDER TYPE 4 GL GIRDER LENGTH (mm) 3120 SL STRUT LENGTH (mm) 1835 12 NUMBER OF MODULE ROWS 2 5 RACK CONFIGURATION (V OR H) Vertical PARTS LIST ITEM QTY PART NUMBER DESCRIPTION 1 4 143008-000-441-157 Post, 8, Galvanized, Custom L= 441 cm A=157 cm 2 4 141000-000 Rail, Girder, FS, Configurable, Assembly 3 12 943912-010 Nut, Flange, Serrated, M10, DIN 6923, 316 SS 4 12 943921-010 Washer, M10, DIN 125,304 SS 5 12 943000-913 Screw, Hex Head, M10x90mm, DIN 931, A2 6 4 142500-000 Head Assembly, Gen 5 7 4 142009-002 Wedge, Safety, Generation 5, ETL 8 40 135002-003 Mid Clamp, Rapid2+, Grounding, 40-50mm, Assembly, ETL 9 8 131001-050 End Clamp, Rapid2+, 50mm, Assembly 10 4 124303-11225 Rail, S1.5, L =11225 mm III Client: Broadway Electric Compa 295 Freeport Street Boston, MA 02122-3592 Ground Mount FS 2V x 11300 HLE17TE ny%7 Exterior Racking Structure 3761 E. FARNUM PLACE I TUCSON, AZ 85706 Details and Palls List TEL: (520) 289 - 8700 1 FAX: (520) 289 - 8596 EMAIL: MAIL@SCHLETTER. US ISSUED BY: SCHLETTER INC. VVVVVV.SCHLETTER.US PROPRIETARY AND CONFIDENTIAL Project Site: DY High School 210 Station Ave South Yarmouth, MA 02664 DESIGN CRITERIA: 2009 EDITION OF THE INTERNATIONAL BUILDING CODE, IN ACCORDANCE WITH STATE OF MASSACHUSETTS AMENDMENTS PER 780 CMR. LOADS: MODULE DEAD LOAD = 2.85 PSF SNOW LOAD = 15.4 PSF (BASED ON 35 PSF GROUND SNOW LOAD) Is= 0.80 Ce= 0.90 Ct= 1.20 Cs= 0.73 WIND DESIGN: DESIGN BASED UPON WIND TUNNEL TEST REPORT# RC 112710510-e BASIC WIND SPEED = 120 MPH (3 SECOND GUST). EXPOSURE:C Iw = 0.77 INSTALLATION TOLERANCES: LATERAL POST PLACEMENT IS ±5.0" TOTAL LATERAL DEVIATION OF POSTS WITHIN AN ARRAY IS ±5.0' POST HEIGHT VARIATION TOLERANCE IS±0.40" POST VERTICALITY TOLERANCE <2.00 IN ALL DIRECTIONS POST ROTATIONAL TOLERANCE <±7.00 ARRAY TILT ANGULAR TOLERANCE ±1.00 GENERAL: 1. THE STRUCTURAL CONSTRUCTION DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OR SEQUENCE OF CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. THE STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES FOR PROCEDURE OF CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND THE PROGRAMS INCIDENT THERE TO (NOR SHALL OBSERVATION VISITS TO THE SITE INCLUDE INSPECTION OF THESE ITEMS). THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL SCAFFOLDING, BRACING AND SHORING. 2. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR MATERIALS, SUCH STANDARDS SHALL BE THE LATEST EDITION AND/OR ADDENDA. ALUMINUM: 1. ALL ALUMINUM SHALL CONFORM WITH THE LATEST ALUMINUM DESIGN HANDBOOK. 2. ALL ALUMINUM SECTIONS SHALL BE 6105-T5. STEEL: 1: ALL BOLTS AND WASHERS SHALL BE 304 STAINLESS STEEL CLASS 2 (A2-70). 2. ALL NUTS SHALL BE 316 STAINLESS STEEL CLASS 2 (A4-70) TORQUE: TORX BOLT FOR RAPID 2+ MODULE CLAMPS IS 14 N -M (10.5 FT -LBS) M6 AND 114" BOLT TORQUE IS 6 N -M (4.5 FT -LBS) M8 AND 5116" BOLT TORQUE IS 14 N -M (10.5 FT -LBS) M10 AND 318" BOLT TORQUE IS 30 N -M (23 FT -LBS) M12 AND 112" BOLT TORQUE IS 50 N -M (37 FT -LBS) M16 AND 518" BOLT TORQUE IS 121 N -M (89 FT -LBS) M20 AND 314" BOLT TORQUE IS 244 N -M (180 FT -LBS) NOTE: RECOMMENDED SPEED FOR INSTALLATION OF SELF -DRILLING 114" DIAMETER SCREWS IS 1200-1800 REIMS. MODULE SIZE: RACKING SYSTEM DESIGNED FOR MODULE SIZE: 1956 mm x 992 mm x 50 mm VERTICAL MODULE GAP: 23 mm HORIZONTAL MODULE GAP: 5 mm FOUNDATIONS: 1. FOUNDATION DESIGN IS BASED UPON PRELIMINARY GEOTECHNICAL REPORT)TESTING REQUIREMENTS BY TERRACON; PROJECT NO: J4129282 ALL CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE GEOTECHNICAL REPORT. 2. THE STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR ANY GEOTECHNICAL ASPECTS OF THIS PROJECT. IF THE INSTALLER NOTICES ANY SOIL THAT HAS DIFFERENT DRIVING CHARACTERISTICS THAN EXISTED FOR TESTED DRIVEN POSTS, CONTACT THE ENGINEER IMMEDIATELY. �/ F Flljq�q�/ \\ o RONALD H. AGN 'rQW? YARMOUTHSCHNEIDER REVIEWED FOR BUILDING AND ZONING CODE COMPLI- STRUCTURAL ANCE. ERRORS OR OMMISSIONS DO NOT RELIEVE THE ? No. 45127 APPLICANT FROM THE RESPONSIBILITY "S S BUILT" COMPLIAN /APoFF S�ONALR�G\����\ 01/1111111 M0 DATE: C BUILDING OFFIC THIS ELECTRONIC SIGNATURE NOTICE HAS BEEN AUTHORIZED BY ME An as built plan must be THIS 10th DAY OF APRIL 2013 submitted to this department prior to foundation inspects iI or any further construction. AV Drawing Number: v.01 JOB NUMBER: v SCALE: SHEET: 2 of 2 SEE DRAWING VIEWS SCHNEIDER STRUCTURAL ENGINEERS FIRM DEDICATION TO STRUCTURAL INNOVATION 1700 E. Ft. Lowell Rd #109 1 Tucson, AZ 85719 1 520.512.8183 1 www.sastructual.com Project Number: 113139 UNLESS THIS DRAWING IS SIGNED AND SEALED BY A LICENSED STRUCTURAL ENGINEER, IT IS A PRELIMINARY DESIGN AND SHALL NOT BE USED FOR CONSTRUCTION.