Loading...
HomeMy WebLinkAbout145 South Street Title 5 Site Plan) LEGEND — 99 — EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. F-9-9:1 PROPOSED CONTOUR 99 PROPOSED SPOT EL. TTH11 0- TEST HOLE 27, SLOPE OF GROUND CQ, UTILITY POLE Q4y FIRE HYDRANT )TE: NOT ALL SYMBOLS MAY APPEAR IN OF *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM 13-314 RUN POND (TIDAL) SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: N/A BOTTOM 30 x 15 (.74) = 333 GPD TOTAL: 450 S.F. 333 GPD USE 4" PERF. PVC PIPE AND STONE LEACH FIELD DIMENSIONS: 30' x 15' x 0.5 DEEP SEE DETAIL SYSTEM PROFILE (NOT TO SCALE) PROVIDE WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. VENT WITH CHARCOAL FILTER 2% SLOPE REQUIRED OVER SYSTEM PRECAST H-10 RISERS (IYP.) PVC 2'0 rj4"oSCH40 PVC PIPES LEVEL 1ST 2' 8.55' TEE 1500 GAL H-10 TEE 83D' SEPTIC TANK ° 00 0 0 0 ;0 0 6" MIN. SUMP 4' LIQ. LEVEL ° °o°o°o°o°o°o o° 7.95' GAS BAFFLE ° °0°0°000°0°0 0° ACME OR EQUAL °i°o°o°o°o°o°o o° 8.15' 7.98' 00 000� 0 000`Oo0o0 000000000 000000000000000000000000 ll� 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) WATER TEST D'BOX FOR LEVELNESS ( % SLOPE) FOUNDATION— 15' — SEPTIC TANK (__L_7 SLOPE) — 15' D' BOX ]RED VENTS( �THERS) AT,61R ABOVE OUTSIDE 12" OF GRADE 2 SIDES. (� % SLOPE) 5' — PROVIDE INSPECTION PORT TO WITHIN " OF FINAL GRADE i- 2" DOUBLE -WASHED PEASTON 40 MIL LINER 5' MIN. OFF LEACHING, TOP AT OR GEOTEXTILE FABRIC n EL. 8.5, BOTTOM AT EL. 4.5 0 >o0oo°000000000000000000000°00 op0000°oo�0000°000°00000 'o°o°o06000°'o°'a°'o°oo°'o o_�o_�000_�o°o°o°o°o°o°a°o°°o°o°'0 0 0°0°'0° °a'Oo°o o°o°'a°o° 7.3' 4" PVC SET AT .005'/' SLOPE / 6" DOUBLE WASHED 3/4" - 1 1/2" STONE-/ 6.0' TIDALLY INFLUENCED GROUNDWATER ELEV. 1.3' MONITORING WELL SET AND AUTOMATED READINGS TAKEN OVER A FULL MOON CYCLE (HIGHEST TIDES OF THE MONTH) LEACHING FACILITY w y SMALL �y AREA DRAIN �I y L� l Bo � I I I III li III SMALL IAREA DRAIN SPEED LIMIT SIGN I UTIL POLE I I I I NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. B. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. WETLAND FLAGGED BY HAMLYN CONSULTING. 13. ROOF RUN-OFF TO BE DIRECTED TO DRYWELLS, OR TO DRIP TRENCHES DATE rarmoum nealm UeparLmeuL DANIEL A. OJALA, P.E., P.L.S. Off 508-362-4541 foi 5C8-362-9880 do, ncepe.com ID down cope engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 \5 4 ca °J Q�e ° �ow SL m m t `? o m A 0 a Locus 4 SoJ,� sr Nantucket Sound LOCUS MAP NOT TO SCALE ASSESSORS MAP 34 PARCEL 266 LOCUS IS WITHIN FEMA FLOOD ZONE AE(EL 12) AS SHOWN ON COMMUNITY PANEL #25001CO589J DATED 7/16/2014 SITE IS IN AN OPA, NO FED. FLOOD INSURANCE AVAILABLE WETLAND FLAGGED BY HAMLYN CONSULTING ZONING SUMMARY ZONING DISTRICT: RS -40 PROVIDED MIN. LOT SIZE 40,000 SF* 17,765 SF UPLAND MIN. LOT FRONTAGE 150'* 91.00' MIN. FRONT SETBACK 30' 67.5' MIN. SIDE SETBACK 20'(6'*) 20.2' MIN. REAR SETBACK 20' 268' *LOT CREATED 12/1/65 (GRANDFATHERED) SITE IS NOT LOCATED WITHIN MESA/NHESP MAPPING TEST HOLE LOGS ENGINEER: LISA LYONS, RS WITNESS: SUSAN RASK, RS DATE: 6/15/05 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS PERCOLATION TESTING PERFORMED 8/31/05 BY RICK JUDD, RS, AMY VON HONE, RS WITNESSING; RATE IS < 2 MIN/INCH IN LS LAYER 120" Q ELEV. ELEV. 4_8' p" 4.7' FILL A/E LS 1OYR 5/1 B LS 1OYR 4/3 1.55' C uOT1LES e 41' (EL. 1.38') MS 1OYR 5/4 A/E MS 18'1OYR 3/1 B LS 1OYR 4/3 40" 1.36' C MS 42" obs. water 1.2' 2.5Y 5/3 -5.2 120" -5.3 OF #145 SOUTH STREET SOUTH YARMOUTH PREPARED FOR VINCENT JAMESON DATE: 12-28-2015 Scde:1 "= 20' 0 10 20 30 40 50 FEET 13-314 JAMESON.DWG