HomeMy WebLinkAbout107 Stratford Lane - Septic Design,
TOP OF FOUNDATION
ELEV. - 100.2L ---N
92.70'
20 FT. MINIMUM FROM CELLAR
10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE
CONCRETE
COVERS 4" SCHEDULE 40 PVC PIPE
MIN. PITCH 1/8" PER FT.
4" CAST IRON PIPE
t
UMFT.FLOW UNE_ 10"
—THIN. 91.151 IEV. _ ..iO4_ GAS ELEV, _ �1_4�_ 6- SUMP EV..
>
BAFFLE DISTRIBUTION
f ELEV. _
EW
(TO BE PLACED ON FIRM BASE) BOX _84.BQ_TO BE WATER TESTED
1500 GALLON IF MORE THAN ONE OUTLET
V TO BE PLACED ON FIRM BASE`) SEPTIC TANK ( 3/4' TO 1 1/2' CLEAN
DOUBLE WASHED STONE
FREE OF FINES k SILT
SEWAGE DISPOSAL SYSTEM PROFILE
NOT TO SCALE
AL
S
TRATFOR� SANE
f CLEAN SAND
INSPECTION PORT OBSERVATION HOLE 1 ELEV.= 94.10 OBSERVATION HOLE 2 ELEV.-_ _94r1U I
LOAM AND SEED PERCOLATION RATE _S_ 2 _ MIN./INCH AT 75* INCHES PERCOLATION RATE . _<__2 MIN./INCH IN C3 HORIZON
2' LAYER OF
1/8' TO 1/2-
50 MAX. WASHED STONE VENT
02.05 MIN. NOT REQUIRED
1 CU. FT, OF
CONCRETE
C) ANCHOR
91.30
_ o
10� ` 89,97
o ELEV. _
4 HIGH CAPSTOTINNLTRRATORS WITH
NE
z 87
DEPTH
HORIZ
TEXTURE
COLOR
MOTT.
OTHER
0-6
O/A
SANDY LOAM
IOYR2/2
NO
ROOTS
6-34
B
LOAMY SAND
10YR5/8
C1
ROOTS
34-64
Cl
MEDIUM SAND
2.5Y7/3
LOAMY SAND 10YR6/4
LEGEND:
64-74
C2
LOAMY SAND
10YR6/4
NUMBER OF BEDROOMS
GARBAGE DISPOSAL UNIT
3
74-90
C3
MEDIUM SAND
7.5YR6/8
TOTAL ESTIMATED FLOW
90-144,
C4
LOAMY SAND
( 110 GAL/B :/DAY X �3_ 8R•)
�4_ GAL/DAY
DEPTH
KURR
I COLOR
MOTT.
OTHER
0-10
A
SANDY LOAM 10YR2/2
NO
ROOTS
10-30
6
LOAMY SAND 1OYR5/8
30-66
C1
MEDIUM SAND 2.5Y7/3
5��*'.�R EAiGlI'11�E'RWG
235 GREAT WESTERN ROAD
508- P. 0. BOX 713
398-3922 SOUTH DENNIS, MASS. 02660 .
66-78
C2
LOAMY SAND 10YR6/4
LEGEND:
DESIGN CALCULATIONS
78-141
C3
MEDIUM SAND 7.5186/8
NUMBER OF BEDROOMS
GARBAGE DISPOSAL UNIT
3
11' X 36' X 10" TRENCH FORMATION
'
WELL N/A
NO WATER ENCOUNTERED AT 144: ELEV. _ __fl214
NO WATER ENCOUNTERED AT 144'
ELEV. _ _8210
SOIL ABSORPTION
ZONE
SYSTEM (SAS)
INDEX
5��*'.�R EAiGlI'11�E'RWG
235 GREAT WESTERN ROAD
508- P. 0. BOX 713
398-3922 SOUTH DENNIS, MASS. 02660 .
ADJUST
LEGEND:
DESIGN CALCULATIONS
EXISTING SPOT ELEVATION OO, 0
NUMBER OF BEDROOMS
GARBAGE DISPOSAL UNIT
3
USGS PROBABLE WATER TABLE ELEV. =
OBSERVED WATER TABLE ( / / ) ELEV. _
_62.SSL
EXISTING CONTOUR ----00----
FINAL SPOT ELEVATION ®
TOTAL ESTIMATED FLOW
BOTTOM OF TEST HOLE ELEV. _
( 110 GAL/B :/DAY X �3_ 8R•)
�4_ GAL/DAY
FINAL CONTOUR---[QQ�—
SOIL TEST LOCATION t9
REQUIRED SEPTIC TANK CAPACITY
-J44- GAL
UTILITY POLE —O
ACTUAL SIZE OF SEPTIC TANK
GAL.
TOWN WATER —WSW—
f®%
SOIL CLASSIFICATION
DESIGN PERCOLATION RATE
SAY MIN./IN.
CATCH BASIN
GAS LINE
EFFLUENT LOADING RATE
A.74 GAL./DAY/S.F.
' S0. FL
CLEAN OUT C
LEACHING AREA
CESSPOOL C.P. O
(1tX38)+(47X2X1O/12)
LEACHING CAPACITY3X,00 (AREA X RATE)
MLN GAL./DAY
474.33 X .74
.,• naav
RESERVE LEACHING CAPACITY
NLQQ GAL:/DAY
()
NOTES:
- -
1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO O.E.P.
V J TITLE 5 AND THE TOWN OF _YARMOUTH RULES AND
REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE.
\ 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO
WITHIN 6' OF FINISHED GRADE.
3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF
WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN
10 FT: OF'DR1VE5 OR PARKING AREAS. H-20 LOADING SHALL BE
m USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS.
4. PNT MASONARY L'ti;TS USED TO BRING COVERS TO GRADE SHALL
�. 8E MORTARED IN PLACE.
5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH
DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO
OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY.
\ 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR
IS TO CALL 'DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS
PRIOR TO COMMENCING WORK ON SITE.
7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS
SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION
IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER
IMMEDIATELY.
B. PARCEL IS IN FLOOD -ZONE
cn 134 ASPARCEL87_�
9. LOT IS SHOWN ON ASSESSORS MAP
0 10. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND
FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE
REPLACED WITH SAND AS SPECIFIED IN 310 CMR 15.255:(3).
jlrk OF k4
e B.P yQ2 T. A. Y
c> p r o DUMAS
No 6199 APPROVED: BOARD OF HEALTH
I TAikkr DATE AGENT
YARM0
IGMEERING
rTG+
LOCUS
c, SETUCKET
v�E 6P
RO ,'' 16 -=
h I,
SES 3 0".2002
—.-- ----
PROPOSED SEPTIC DESIGN
FOR
DUBLIN CONSTRUCTION
PROJECT LOCATION TOT 22
107 STRATFORD LNII YARMOUTH
1�JJ
5��*'.�R EAiGlI'11�E'RWG
235 GREAT WESTERN ROAD
508- P. 0. BOX 713
398-3922 SOUTH DENNIS, MASS. 02660 .
DATE MAY 16, 2002
FScALE 1„ —' 20'
REV.SEPT. 26, 2002
JOB 110. 5406-'00
SHEET 1 OF 1