HomeMy WebLinkAbout107 Stratford Lane - Septic Design 5DEPTH
HORIZ TEXTURE
COLOR
MOTT.
OTHER
Z LATLN Ut
0/A'SANDY LOAM
10YR2/2
NO'
ROOTS
6-34
8 LOAMY SAND
1 /8- TO 1/2-
B
ROOTS
6.50
Cl MEDIUM'SAND
2.5(7/3
30-66
WASHED STONE
94.30 MAX
VENT
C2 LOAMY SAND
10YR6/4
4" CAST IRON PIPE
66-78
74-90
92.05 MIN.
NOT REQUIRED
SLAB ELEV. = 92.70
(OR EQUAL) MINIMUM-
C4' LOAMY SAND
MEDIUM SAND
?
1 CU. FT, OF
PITCH 1/4" PER FT.
LOCATION' MAP.
REVISED
CONCRETE
FLOW LINE
91.30 b
ANCHOR ,
-
ELEV. 91.70
10"
"''MIN.
2.0,,
a o _ o
i LEV.
_ 91.15 LEVEL
o = 010. 10T
_ - ELEV.,
89.97
ELEV. _ _91�Q_ .
GAS ELEV.
_ _9L05_ 6" SUMP ELEV. _ 90.&3_
BAFFLE
DISTRIBUTION
LIQUID
OUTLET
1
ELEV.
BOX 90.80_
4 HIGH CAPACITY INFILTRATORS WITH
STONE IN AN
QEPTH
TEE
(TO BE PLACED ON FIRM BASE)87
DEPTH
HORIZ TEXTURE
COLOR
MOTT.
OTHER
0-6
0/A'SANDY LOAM
10YR2/2
NO'
ROOTS
6-34
8 LOAMY SAND
10YR5/8
B
ROOTS
34-64
Cl MEDIUM'SAND
2.5(7/3
30-66
Cl
64-74
C2 LOAMY SAND
10YR6/4
66-78
74-90
C3 MEDIUM SAND
7.SYR6/8
90-144
C4' LOAMY SAND
MEDIUM SAND
7.5YR6/8
DEPTH
HORIZ
TEXTURE
COLOR ...MOTT.
OTHER
0-10
A
SANDY LOAM
10YR2/2'
NO
ROOTS
10-30
B
LOAMY SAND
10YR5/8
:
30-66
Cl
MEDIUM SAND
2.5Y7/3
66-78
C2
LOAMY SAND
10YR6/4
78-14
.C3
MEDIUM SAND
7.5YR6/8
4 FEET 14 INCHES TO BE WATER TESTED 11' X 35' X 10' TRENCH FORMATION '
6 FEET 24 (INCHES 1500 GALLON IF MORE THAN ONE RM BA �+ pT� ° WELL NIA NO WATER ENCOUNTERED AT _: 44= ELEV. _X8219 NO, WATER ENCOUNTERED AT _144" ELEV.
7 FEET 29 INCHES c T7 A 'l (TO BE PLACED ON FIRM BASE) SOIL ABSORr I OZONE
8 FEET 34 INCHES SEPTIC TANK 3/4" TO 1 1/2" CLEANS Vim+TEiS� (SAS)
DOUBLE WASHED STONE S ! JAS, INDEX
FREE OF FINES & SILT LEGEND: DESIGN CALCULATIONS
�+ �+ vc► C USGS PROBABLE WATER TABLE ELEV. - _ EXISTING SPOT ELEVATION 00,0 NUMBER OF BEDROOMS _3�
SEWAGE DISPOSAL S STEM PROFILE OBSERVED WATER TABLE ( / / ) ELEV. _ EXISTING CONTOUR ---00---- GARBAGE DISPOSAL UNIT 1iQ_
NOT TO SCALE BOTTOM OF TEST HOLE ELEV.. FINAL SPOT ELEVATION M TOTAL ESTIMATED FLOW
FINAL CONTOUR-----= ( 110 GAL./BR./DAY X 3DR.) _NQ- GAL./DAY
SOIL TEST LOCATION REQUIRED SEPTIC TANK CAPACITY .�4_ GAL.
UTILITY POLE -0- ACTUAL SIZE OF SEPTIC TANK 1500 GAL.
TOWN WATER —WSW SOIL CLASSIFICATION
CATCH BASIN �®N DESIGN PERCOLATION RATE 5�_ MIN./IN.
GAS UNE GG`�7 EFFLUENT LOADING RATE --OJ-+- GAL./DAY/S.F.
CLEAN OUT C.O. LEACHING AREA A74.33 SQ. FT.
/ CESSPOOL - C.P. Q HG+(47X2IClOO
LEACAREA X RATE) MUM GAL./DAY
✓ fr / . i = 474.33 X 0.74
R D s �
RESERVE LEACHING CAPACITY 151.04GAL/DAY MOON
A NOTES. 1 TITLE 5ANDTHETOWN
RNPAND MATERIALS SHALL CONFORM TO D.E.P.
• OF ___YARMOUTH RULES AND
REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE.
J 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO
NITHIN 6" OF FINISHED GRADE
3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF
120.90 WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN
" ARAS. H-20 LOADING
Bl7-ASPHALT
ROAD USED UNDER IORSWITHIN ARO IFT. OFEDRIVES OR PARKINGSHALL AREAS. E
4. ANY MASONARY UNITS USED TO BRING COVERS TO'GRAOE SHALL
BE MORTARED IN PLACE.
SDETERMINATION BEEN WTH
OE AS O
TIONS. /
APPLICANT COMPLIANIS TO
" DEEDED ORZONING REGULA
OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY.
6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR
" IS TO CALL "AIG -SAFE AT 1-888-344-7233 AT LEAST 72 HOURS
PRIOR TO COMMENCING WORK ON SITE.
7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS
SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION
IS TO BE BROUGHT TO THE ATTENTION OF THE, DESIGN ENGINEER
. � IMMEDIATELY.� -
S. PARCEL IS IN ROOD ZONE C
$ 9. LOT IS SHOWN ON ASSESSORS MAP _ 134 AS PARCEL 87
10. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND
FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE
REPLACED WITH SAND AS SPECIFIED 1N' 310 CMR 15.255:(3).
4p yg. OROy V VAS
\ _ 3 gEpR OOIygL G9 1, T A.
0 =+ t
. BOARD OF HEALTH
1341 'APPROVED: > � � APPROVED ..
f Oa F ST£R
Ok �+D 51t �p �"4MIT0.P11.N m
_ 1500 GALLON / rj� �•� DATE AGENT
/vT�r
Lo v�
SETUCKET
6P
ROS
PROPOSED SEPTIC,DESIGN
FOR '
DUBLIN comMUCTION
PROJECT LOCATION f1f
LOT
107 STRATF RD (Tv'T�
L� . YARMOM
sr.=M? G
235 GREAT WESTERN ROAD
P. 0. BOX 713
398 3922 SOUTH DENNIS, MASS. 02660
DATEM AY -16, :2002
SCALE .1 " = 20'
Fj_oB NO. 5406-00
REVISED 7
SHEET 1 0F' 1
LOCATION' MAP.
REVISED