Loading...
HomeMy WebLinkAbout10 Susan Road Site PlanTOP FNDN. AT EL. 12.5' SYSTEM PROFILE ACCESS COVER TO FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM 10,2' EL. 10.2' RUN PIPE LEVEL FOR FIRST 2' PROPOSED1500 9.05' GALLON SEPTIC 8 8' � TANK (H- 10 ) GAS m31, rW/FAST SYSTEM BAFFLE 8.48' �� 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) DEPTH OF FLOW = 4 ( MI % SLOPE) (-% SLOPE) LAGOON (TIDAL) 3' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER (TO Cl LAYER - SEE TH LOG REPLACE WITH CLEAN MED. SAND. PROVIDE SHORING AS NECESSARY DURING EXCAVATION FOR SYSTEM 02-218 L-33.29' 1 R=23.87' Io.� 1 1 1 9.7 4 9.7 1 \ 38.0 rHlz � 1 �>\ 1 la # .6 cn p 1 VIED RIVE \\, 6'� LTi 8.7 / O -+9. F 6 1 \ do lil 32' D' BOX L0 t 2" DOUBLE WASHED PEASTONE - j8' TEE SIZES: LOGS v 0000 0 0000 0 0000 INLET DEPTH = 10 5.6 4" AIR PIPING OUTLET DEPTH = 14" II 3/4" TO FOUNDATION- EXIST - SEPTIC TANK *THE INSTALLER SHALL VERIFY THE 6.3 LOCATIONS OF ALL UTILITIES AND ALL 6.5 BUILDING SEWER OUTLETS AND ELEVATIONS / ;1- 6,$ 6.4 PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM / 6.3 cv J / w /6.5 0) 'k 6.6 11.8' / PAVED DRIVE 10.2' / / S0, 3 -RC ® 0/A 82" 10YR 8/6 121" 6,5/6.9O�Y 11'i C2 //NCO U 7,8 7.0 24" 4,8 500 GAL 1000 GAL. / � 7.4 7.3 .3 /L=51.67' TH 11.8 40.59] 1 6.4 \ _ FAST 0.5 SYSTEM I 00 1 7.3 \ EXIST DWELL. o k 7.5 TF 12.5' tp 1 11.7 17.4 I N PROVIDE APPROX. 46' OF 40 MIL LINER o /is BETWEEN SAS AND FOUNDATION AS 1 1 5C; a -i "n"Y PO / 0 SHOWN 0 -f�11 0' TOP AT EL. 9.0' / 00 LAGOON (TIDAL) 3' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER (TO Cl LAYER - SEE TH LOG REPLACE WITH CLEAN MED. SAND. PROVIDE SHORING AS NECESSARY DURING EXCAVATION FOR SYSTEM 02-218 L-33.29' 1 R=23.87' Io.� 1 1 1 9.7 4 9.7 1 \ 38.0 rHlz � 1 �>\ 1 la # .6 cn p 1 VIED RIVE \\, 6'� LTi 8.7 / O -+9. F 6 1 \ do lil 32' D' BOX L0 t 2" DOUBLE WASHED PEASTONE - j8' 0000 0000 0000 LOGS v 0000 0 0000 0 0000 = �p 5.6 4" AIR PIPING II II II I � II 3/4" TO 1 1/2" DOUBLE WASHED STOVE **FILL BASE OF CHAMBERS WITH 0.5' CLEAN MEDIUM SAND PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 101 13' SOILS LEACHING Fo� w Q FACILITY SEE NOTE 1 SEE NOTE 2 MEAN HIGH WATER ON WALL 7.9 PUMP AND REMOVE EXISTING SEPTIC TANK INSTALL F.A.S.T. SYSTEM IN 1500 GAL TANK (SPECIAL ORDER) BENCH MARK - TOP END OF CONCRETE SEA WALL - 3.1 ELEVATION = 7.9 (NGVD) 0.75' MIN 9.03' 6.72' 5' USE WATER ELEV. AT 1.72' (TIDALLY INFLUENCED) P WATER OUTLET 1. BLOWER TO BE REMOTED NO GREATER TEST HOLE LOGS - ENGINEER: JOHN HUNTER 5.6 4" AIR PIPING II II II I � II DESIGN FLOW: _4 BEDROOMS ( 110 GPD) = 50'4"SCH BRUCE MURPHY, RS DATE: 5/20/00 LS DATE: 7/22/03 22" 40 PVC (TYP.) LEACHING: PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 101 IN FROM HOUSE8 3" MIN. ABOVE SOILS 11 C1� Fo� w Q 0 11.8' 0" 10.2' OUR.Ef 6"OHOLE -RC ® 0/A 82" 10YR 8/6 121" OBS WATER 1.72' C2 U 7,8 MED/COS 24" 132" 10YR 8/1 p 500 GAL 1000 GAL. .3 38' _ FAST 0.5 SYSTEM MEAN HIGH WATER ON WALL 7.9 PUMP AND REMOVE EXISTING SEPTIC TANK INSTALL F.A.S.T. SYSTEM IN 1500 GAL TANK (SPECIAL ORDER) BENCH MARK - TOP END OF CONCRETE SEA WALL - 3.1 ELEVATION = 7.9 (NGVD) 0.75' MIN 9.03' 6.72' 5' USE WATER ELEV. AT 1.72' (TIDALLY INFLUENCED) P WATER OUTLET 1. BLOWER TO BE REMOTED NO GREATER TEST HOLE LOGS - ENGINEER: JOHN HUNTER ENGINEER: AH OJALA, PE WITNESS: KELDA GORMAN DESIGN FLOW: _4 BEDROOMS ( 110 GPD) = WITNESS: BRUCE MURPHY, RS DATE: 5/20/00 LS DATE: 7/22/03 22" PERC. RATE _ < 2 MIN/INCH LEACHING: PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 101 CLASS 1 SOILS 11 C1� ELEV. 10YR 5/6 Q 0 11.8' 0" 10.2' FILL -RC ® 0/A THAN 100' FROM SYSTEM 2. OPERATIONS AND MAINTENANCE - AGREEMENT REQUIRED FOR LIFE OF 15" SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) DESIGN FLOW: _4 BEDROOMS ( 110 GPD) = A USE A 440 GPD DESIGN FLOW LS 22" 10YR 3/1 LEACHING: B 101 SIDES: LS BOTTOM: - 33.5 x 12.83 (.74) = 318 10YR 5/6 28" OR 9.4' Cl -RC ® MED/COS 82" 10YR 8/6 121" OBS WATER 1.72' C2 MED/COS 132" 10YR 8/1 0.80' THAN 100' FROM SYSTEM 2. OPERATIONS AND MAINTENANCE - AGREEMENT REQUIRED FOR LIFE OF FAST SYSTEM SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) DESIGN FLOW: _4 BEDROOMS ( 110 GPD) = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (-Z--) = 880 USE A 1500- GALLON SEPTIC TANK W/FAST SYSTEM LEACHING: 2(33.5 + 12.83) 1.48 (.74) = 101 SIDES: BOTTOM: - 33.5 x 12.83 (.74) = 318 TOTAL: 566 S.F. 419 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND 7.4 FOLLINS POND (TIDAL) LEGEND NOTE: PORTION OF EXISTING LEACHING FACILITY MAY BE WITHIN AREA OF PROPOSED SYSTEM 1I �f- 0 84 +BB 2013 ADDED NOTES + DORMERS PROPOSED ON SECOND FLOOR ON POND -SIDE 6.o OF DWELLING SEPTIC SYSTEM HAS BEEN INSTALLED 8., -1 m 0 0 0 + 8.2 r 6 03 m WORK MUST NF RM TO ALL 4 z TOWN B S EGULATI S 8.1 .4 66-6 EPT DATE 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION [fool PROPOSED CONTOUR 100 EXISTING CONTOUR BOARD OF HEALTH APPROVED DATE MA off 508-362-4541 fax 508 362-9880 down cape engineering, Inc, CIVIL ENGINEERS LAND SURVEY❑RS 939 slain st. yarmouth, ma 02675 12" B LS 1OYR 5/2 28" 7.87' C COS 114" OBS WATER 0.7' 2.5Y 5/6 120" 0.2' ASSESSORS MAP 127 PARCEL 37 VARIANCES REQUESTED UNDER MAX. FEASIBLE COMPLIANCE .15.405: 1a: REDUCTION IN SETBACK, SAS TO LOT LINE (10' To 0') 1b: REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 10') 1d: REDUCTION IN SIZE OF LEACHING FACILITY BY 5% TOWN OF YARMOUTH REG 3.7: REDUCTION IN SETBACK TO WETLAND (100' TO 50') NOTES: 1. DATUM IS NGVL) 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. PUMP & REMOVE EXISTING TRENCHES TITLE 5 SITE PLAN OF 10 SUSAN ROAD IN THE TOWN OF: YARMOUTH (PORT) PREPARED FOR: SCOTT PETERSEN 30 0 30 60 90 SCALE: 1" = 30' DATE: AUGUST 22, 2003 REV 1/3/04 (ALT. SYSTEM) REV 8/28/13 (NOTES) DANISLA. ye s% DANIEL OJALA A. m 0 CIVILOJALA No. 46502 d,'.A 4 .40380 PST SfONAI E P.V C,10 °Y V I mss/ 1 -3 DANIEL A. OJALA, P. E., P.L.S. DATE