Loading...
HomeMy WebLinkAbout12 Swordfish Drive - Bulkhead Repair 2ASSESSOR'S MAP 25 PARCEL 13 16 SWORDFISH DRIVE N RALPH K TOMASIAN PAMELA W MYERS 16 SWORDFISH DR SO YARMOUTH, MA 02664 REMOVED AND(REPLACED LIMIT -� _ r r r ►EXISTING TO BE r , EXISTING TIMBER BULKHEAD. A.H.T. EL 2.1 1 r r r r r r M.H.W. EL 1.8 1 -1 �- � 0 M.LW. EL -1.1 iA r r 1 O o, r X .2 1 � DpSDNG 2.2 11fi X 1] 1 (SHOREGUARD ® LANDING • ' ! -4.8 °. PARKER'S RIVER ! r m . _..., ` 1 1 X 5.2 1 p ! pp5D1lG TIMBER ! OF WALL EL 6.5' N.G.V.D. 1 r f .r- REED e -3.5 a` ! S P h I D OPPOSITE SHORELINE e i 1 2 7 i NO SCALE e F 1 Z e F° 6'x 6' GREENHEART ANCHOR WALE L ♦ ASSESSOR'S MAP 25 PARCEL 13 16 SWORDFISH DRIVE N RALPH K TOMASIAN PAMELA W MYERS 16 SWORDFISH DR SO YARMOUTH, MA 02664 REMOVED AND(REPLACED LIMIT -� _ r r r ►EXISTING TO BE r , EXISTING TIMBER BULKHEAD. FLOOD NOTE: r r r r r .._-, 1 -1 �- � 0 REPLACED INS AME FOOT iA r r 1 o, r X .2 PRINT WITH VINYL SHEETINGr CL9000 OR r �' of 500605,080 r DpSDNG 2.2 11fi X 1] LOW$ +' (SHOREGUARD ® LANDING • ' �p eI � EQUAL) ,,go r m . _..., ` SWORDFISH DR B �LK1i X 5.2 p pp5D1lG TIMBER X 5.2 X 5.8tFDG OF WALL EL 6.5' N.G.V.D. 1 r f .r- REED iND REG S P -3.2 i f ; KEY MAP 7 i NO SCALE 1 MUOUNE -2.6 MHW EL 1.8 6'x 6' - GREENHEART BOTTOM WALE MLW -1.1 REMAIN) V MIN. EMBEDMENT FOR PROPOSED 1' THICK x P U WELD `H;x6. GREENHEART MIDDLE WALE . TI a .. IIF CL -9000 VINYL EETING 18' MIN. LENGTH PROPOSED 3'x W PT BACK WALE (THRU-BOLT 2' D.C.) WITH 3/4' HARDWARE EMBEDMENT WITH 1B' SH', RED. CONTACT ENGINEER ;H WELD CONNECTION. EACH TIE -B, DEVELOP 11 KIPS MINIMUM. R/DEADMAN SIZE AND TYPE SHALL SECTION A -A SCALE 1":2' ASSESSOR'S MAP 25 PARCEL 15 8 SWORDFISH DRIVE N LINDA M AL1 FAISAL I ALI 47 ANTHONY RD DALTON, MA 01226 6000 BUFFER _r r/ 00000 -- 0.000050�� too BUFFER �os owspoto l SWORDFISH DRIVE PLAN 10 5 0 10 1 inch a 10 fL 30 COASTAL ENGINEERING COMPANY, INC. 260 Cranberry Hwy. Orleans, MA 02653 508.255.6511 Far. 508.255.6700 m v0lp s� r NANTUCKET SOUND PLAN REFERENCES: 0 ASSESSORS MAP 25, PARCEL 14 5 FLOOD NOTE: VARIESPROPOSED 3'x 8' PT BACK WALE F(TH1U-BOLT 1 GENERAL NOTES: 2' O.C.) WITH 3/4' HARDWARE EXISTING 3'X10' CAP FLOOD ZONE Al2 (EL 12) AS SHOWN ON LGRADE(2) (VARIES) HE PLANTTOP FEMA FIRM PANEL #250015 0006D OF WALL EL 6.5' N.G.V.D. iND REG REVISED JULY 2, 1992 2. THE EXISTING TIMBER BULKHEAD IS PERMITTED UNDER CHAPTER 91 WATERWAYS'UCENSE (#6075) FROM THE 6'x 6' GREENHEART ANCHOR WALE i EiiSTING TIE BACK TO BE, . i?0 3. SUPPLY MATERIAL, EQUIPMENT AND LABOR TO INSTALL THE PROPOSED WORK ALONG THE SHOREFRONT AS Bf:OKEN AT INTERSECTION OF':PROPOSED,TIE BACK . DESCRIBED AND SHOWN ON THE PLAN AND DETAILS. ELEVATIONS SHOWN HEREON ARE BASED AMD WELDED TOGETHER WIT -1 IN 1' WELD ON THE NATIONAL GEODETIC VERTICAL 4. PERFORMANCE OF THE WORK SHALL BE IN COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND ORDER OF DATUM 1929 (NGVD 1929) RM CONDITIONS ISSUED BY THE YARMOUTH CONSERVATION COMMISSION FOR THE REFERENCED PROJECT AND AS DESCRIBED BELOW. z , MUOUNE -2.6 MHW EL 1.8 6'x 6' - GREENHEART BOTTOM WALE MLW -1.1 REMAIN) V MIN. EMBEDMENT FOR PROPOSED 1' THICK x P U WELD `H;x6. GREENHEART MIDDLE WALE . TI a .. IIF CL -9000 VINYL EETING 18' MIN. LENGTH PROPOSED 3'x W PT BACK WALE (THRU-BOLT 2' D.C.) WITH 3/4' HARDWARE EMBEDMENT WITH 1B' SH', RED. CONTACT ENGINEER ;H WELD CONNECTION. EACH TIE -B, DEVELOP 11 KIPS MINIMUM. R/DEADMAN SIZE AND TYPE SHALL SECTION A -A SCALE 1":2' ASSESSOR'S MAP 25 PARCEL 15 8 SWORDFISH DRIVE N LINDA M AL1 FAISAL I ALI 47 ANTHONY RD DALTON, MA 01226 6000 BUFFER _r r/ 00000 -- 0.000050�� too BUFFER �os owspoto l SWORDFISH DRIVE PLAN 10 5 0 10 1 inch a 10 fL 30 COASTAL ENGINEERING COMPANY, INC. 260 Cranberry Hwy. Orleans, MA 02653 508.255.6511 Far. 508.255.6700 m v0lp s� r NANTUCKET SOUND PLAN REFERENCES: 0 ASSESSORS MAP 25, PARCEL 14 5 8'f 3/4' THRU BOLT 0 2' O.C. FOR SHOREGUARD ANCHOR WALE (COUNTERSUNK) CL-9DD:1 VINYL SHEETING, E; FEET LONG �--- 2't O.C. --� , I 'I II 10' II II .I T u n T IP 1'X V WELD TO ATTACH PROPO! Ill ANCHOR TIE RODS 1-1/2' MIN. DIA. TIE ROD TO EXI'. I 0 8'f O.C. UIQANCHOR FORCE = 11 KIPS MM. II TO BE WELDED TO EXISTING TIE ROD II BULKHEAD DETAIL: NOT TO SCALE 10' (MIN.) EXISTING PILE (TO REMAIN) r- GREENHEART ANCHOR WALE 6'X 6' 3'X 8' BACK WALE FE9 212012 HEALTH DEPT. w W O �a w a U O a C R h SCALE AS NOTED DRAWING FILE C17657.dwg DATE 11-30-11 DRAWNBY RES CHECKEDBY 0 N V 3.. OF t SHEETS o PROJECT NO. (✓'17657.00 U FLOOD NOTE: 1 GENERAL NOTES: FLOOD ZONE Al2 (EL 12) AS SHOWN ON 1. THE PURPOSE OF THIS PROJECT IS TO RECONSTRUCT AN EXISTING FAILED TIM3E- BULKHEAD. FEMA FIRM PANEL #250015 0006D REVISED JULY 2, 1992 2. THE EXISTING TIMBER BULKHEAD IS PERMITTED UNDER CHAPTER 91 WATERWAYS'UCENSE (#6075) FROM THE DEPARTMENT OF PUBLIC WORKS. THE BULKHEAD WILL BE RECONSTRUCTED IN THE EXISTING FOOTPRINT. DATUM NOTE: 3. SUPPLY MATERIAL, EQUIPMENT AND LABOR TO INSTALL THE PROPOSED WORK ALONG THE SHOREFRONT AS DESCRIBED AND SHOWN ON THE PLAN AND DETAILS. ELEVATIONS SHOWN HEREON ARE BASED ON THE NATIONAL GEODETIC VERTICAL 4. PERFORMANCE OF THE WORK SHALL BE IN COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND ORDER OF DATUM 1929 (NGVD 1929) CONDITIONS ISSUED BY THE YARMOUTH CONSERVATION COMMISSION FOR THE REFERENCED PROJECT AND AS DESCRIBED BELOW. a 5. ACCESS TO BE FROM THE UPLAND OF THE APPLICANT'S PROPERTY. STAGING AREA FOR MATERIALS TO BE IN DRIVEWAY. z 6. METAL TO BE HOT DIPPED GALVANIZED 'AFTER FABRICATION. SEAL 7. SHEETING MATERIAL SHALL BE SHOREGUARD CL -9000. MINIMUM SHEETING LENGTH SHALL BE 18'. i OF sgyc 8. THE EXISTING ANCHOR SYSTEM WILL BE UTILIZED. THE EXISTING TIE BACKS WI1 BE BROKEN AT A POINT / o OWSKI DETERMINED IN THE FIELD, AND THEN SHALL BE WELDED TO PROPOSED 1-1/2" DIAIIETER TIE RODS MINIMUM. THE o 145 N PROPOSED WALL REPLACEMENT IS DESIGNED FOR 8' EXPOSURE. THE ANCHOR FORCE IS 11 KIPS. ANCHORS SHALL BE b PF FFss TENSIONED TO CALCULATED ANCHOR FORCE MINIMUM THEN BACKED OFF AS NECES9RY TO STPAIGHTEN. WALL ENGINEER SHALL BE NOTIFIED IMMEDIATELY IF MINIMUM DESIGN SPECIFICATIONS CW NOT BE ATTAINED. A TORQUE LOG oNn1 E SHALL BE KEPT BY CONTRACTOR DURING INSTALLATION OF ANCHORS AND GIVEN TO 'ENGINEER AT COMMENCEMENT OF INSTALLATION. A PULL TEST SHALL ALSO BE IMPLEMENTED AND WITNESSED BY ENJINEER. 9. CONSTRUCTION DETAILS TO BE APPROVED BY ENGINEER PRIOR TO CONSTRUCTOJ. 10. DISTURBED AREAS TO BE REVEGETATED TO MATCH PRE -CONSTRUCTION CONDTIONS. x 11. CONTRACTOR TO VERIFY ALL DIMENSIONS IN THE FIELD AND NOTIFY EPIGINEEP. AFI ANY DISCREPANCIES PRIOR TO O CONSTRUCTION. 12. ANY CHANGES TO ANCHORS AND SPECIFICATIONS SHALL BE APPROVED BY THE ENGINEER IN WRITING PRIOR TO IMPLEMENTATION. ^ 0 8'f 3/4' THRU BOLT 0 2' O.C. FOR SHOREGUARD ANCHOR WALE (COUNTERSUNK) CL-9DD:1 VINYL SHEETING, E; FEET LONG �--- 2't O.C. --� , I 'I II 10' II II .I T u n T IP 1'X V WELD TO ATTACH PROPO! Ill ANCHOR TIE RODS 1-1/2' MIN. DIA. TIE ROD TO EXI'. I 0 8'f O.C. UIQANCHOR FORCE = 11 KIPS MM. II TO BE WELDED TO EXISTING TIE ROD II BULKHEAD DETAIL: NOT TO SCALE 10' (MIN.) EXISTING PILE (TO REMAIN) r- GREENHEART ANCHOR WALE 6'X 6' 3'X 8' BACK WALE FE9 212012 HEALTH DEPT. w W O �a w a U O a C R h SCALE AS NOTED DRAWING FILE C17657.dwg DATE 11-30-11 DRAWNBY RES CHECKEDBY 0 N V 3.. OF t SHEETS o PROJECT NO. (✓'17657.00 U