HomeMy WebLinkAbout176 Union Street Proposed Septic System Upgrade 2*NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. EXCEPT THE 2" DIAM. SCH.40 FORCE MAIN *NOTE: INSTALL GAS BAFFLE OR EQUAL ON SEPTIC TANK OUTLET TEE. INLET INLET Finished grade over system=2% slope away DIST. eax Existin Grade SEPTIC TANK m `n E d gyp. ewer ¢� iNthain'�B- d tiniaM1ad 9 °" o Liquid Pump Chamber cover must be wMiecery, eca Mr�rhw� a e, Win, r-i/T-tri• �• mai Existing House Septic tank covers must be to finished grade�e d 2, dov!Se eeahed .t.e _ j First FI. elev.= 108.25' 6" below finished grade •` 8'—Gw s -.o1 4'-10" ToD Pe END -SECTION 1000 GALLON I 4 PUMP CHAMBER /Im\ Shdt _ a e e c c e 2a• Nr�. INLET INLET L=4' 6" OF 3/4"-11/2" STONE c PUMP ` CHAMBER 4' 6" OF 3/4"-11/2" STONE - 2-24" DIAM. ACCESS MANHOLES STEEL REINFORCED PRECAST CONCRETE PLAN VIEW ` 2-24" REMOVABLE COVERS 3" 3" 6" max.# 12" min. inlet to outlet OUTLET OUTLET N M 12" INLET 6. OF 3le-111r STONE SYSTEM PROFILE Not to Scale LEACH TRENCH A BOTTOM OF TEST HOLE #1 ELEV=94.72' (NO GW ENCOUNTERED) ADJUSTED GW ELEV.=94.2' (top of bank at edge of wetland) VGW Elev.=92.61' (Observed standing in wetland) PUMP NOTES &- SPECIFICATIONS 1. PROVIDE 1 MEYERS SRM 4/10 H.P., 115 VOLT, SINGLE PHASE SUBMERSIBLE PUMP CAPABLE OF PASSING INLET INVERT A MINIMUM SOLID SIZE OF 2" DIAMETER OR EQUAL. ELEV.= 100.1 2. USE MEYERS CE11SW SIMPLEX ELECTRIC CONTROL PANEL INDOOR MOUNTED W/VISIBLE ALARM OR EQUAL 3. PUMP SHALL BE INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALARM SHALL CONSIST OF AUDIBLE SIGNAL & RED WARNING LIGHT TO BE INSTALLED IN BUILDING AND POWERED BY SEPARATE CIRCUIT FROM CIRCUITS TO PUMP. 5. DOSE VOLUME=4 DOSES PER DAY= 440 GAL/4 DOSES=110 GAL./DOSE 6. ELECTRICAL PERMIT REQUIRED FOR ALARM & POWER TO PUMP. 1 f0" min. 1 T EXISTING 1,000 GAL SEPTIC TANK m `n E d o 4'-0" min. o L=4' 6" OF 3/4"-11/2" STONE c PUMP ` CHAMBER 4' 6" OF 3/4"-11/2" STONE - 2-24" DIAM. ACCESS MANHOLES STEEL REINFORCED PRECAST CONCRETE PLAN VIEW ` 2-24" REMOVABLE COVERS 3" 3" 6" max.# 12" min. inlet to outlet OUTLET OUTLET N M 12" INLET 6. OF 3le-111r STONE SYSTEM PROFILE Not to Scale LEACH TRENCH A BOTTOM OF TEST HOLE #1 ELEV=94.72' (NO GW ENCOUNTERED) ADJUSTED GW ELEV.=94.2' (top of bank at edge of wetland) VGW Elev.=92.61' (Observed standing in wetland) PUMP NOTES &- SPECIFICATIONS 1. PROVIDE 1 MEYERS SRM 4/10 H.P., 115 VOLT, SINGLE PHASE SUBMERSIBLE PUMP CAPABLE OF PASSING INLET INVERT A MINIMUM SOLID SIZE OF 2" DIAMETER OR EQUAL. ELEV.= 100.1 2. USE MEYERS CE11SW SIMPLEX ELECTRIC CONTROL PANEL INDOOR MOUNTED W/VISIBLE ALARM OR EQUAL 3. PUMP SHALL BE INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALARM SHALL CONSIST OF AUDIBLE SIGNAL & RED WARNING LIGHT TO BE INSTALLED IN BUILDING AND POWERED BY SEPARATE CIRCUIT FROM CIRCUITS TO PUMP. 5. DOSE VOLUME=4 DOSES PER DAY= 440 GAL/4 DOSES=110 GAL./DOSE 6. ELECTRICAL PERMIT REQUIRED FOR ALARM & POWER TO PUMP. 1 f0" min. 1 T m `n E d o 4'-0" min. o Liquid depth 1, 4'-3- j C 4..'.. 6" 1'. Y •` 8'—Gw 4'-10" CROSS-SECTION END -SECTION 1000 GALLON H-10 SEPTIC TANK AS PUMP CHAMBER NOT TO SCALE 24" DIAMETER COVER TO FINISHED GRADE LIFT OUT CHAIN a1 I OUTLET INVERT ELEV =99.92' 3/8" WEEP HOLE ABOVE CHECK VALVE 26" OR 440 GALS. (FREEZE PROTECTION) 24 HR. Reserve Storage 2" SWING CHECK VALVE-P.V.C. HIGH WATER ALARM ELEV.-98.17' 50" 2" PUMP ON ELEV.-98.00- 7" PUMP OFF ELEV.=97.42' e 16" e.. FLOOR PUMP CHAMBER ELEV.-95.92' A . of 3/4" — 11/2" Stone PUMP DETAIL Not t4. Scale Nd63:13:6901£319- l ]OVd l 1300N SHVI_nIMHSVO-.-,