Loading...
HomeMy WebLinkAbout42 Vesper Lane - Site Plan of Land 21 F c GENERAL NO TES : 1. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS NGVD. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTEMANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. r 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' 1N DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 6. SEPTIC TANK. PUMP CHAMBER AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. ALL UNSUITABLE MATERIAL (A A B HORIZONS. Cl LAYER) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. 9. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. 10. 1T SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. PUMP SYSTEM NOTES: 1. PUMP TO BE MYERS RESIDENTIAL SEWAOE PUMP MODEL SRM4 OR EQUAL. 2. THE PUMP SHALL START AND STOP AT THE ELEVATIONS SHOWN. J. THE PUMP SHALL BE INSTALLED IN STRICT CONFORMANCE WITH THE MANWFACTURFR'S SPECIFICATIONS AND TITLE V REGULATIONS. PUMP DISCHARGE SHALL BE 2 INCHES. PUMP SHOULD BE ABLE TO BE DISCONNECTED AND LIFTED OUT OF THE PUMP CHAMBER BY THE LIFTING CHAIN WITHOUT HAVING TO ENTER THE PUMP CHAMBER. 4. THE ALARM SHALL START AT THE ELEVATION SHOWN AND BE POWERED BY A CIRCUIT SEPARATE FROM THE PUMP POWER. PVC OUTLET E LEGEND EXISTING CONDITIONS 0 CONCRETE BOUND FOUND m WATER GATE -W- WATER L I NE 0 HYDRANT 9 GAS GATE i -G- 'GAS LINE ® CATCH BASIN -- OVER HEAD WIRES A�I o -P LNE TREE / SIZE S TYPE -"0.4 EXISTING ELEVATION ----26--- EXISTING CONTOUR 0 5 PROPOSED GRADE n PROPOSED CONTOUR BM HYD TAG BOLT EL -35.40 2I 23 23. "V Ln UP RED um o, h 28' OAK 0 M y so.l OF WALL ] ,+27.3 DM CB/DH EL -34.90 To EL.I✓ 12..o c� S/2q�4 9 wtTFc {Jr, G4.nUWa i7 WIk-fL'}�. l 0 ACCESS COVERS MUST BE WITHIN 6' OF FINISH GRADE 2' 615 1500 GAL PUMP CHAMBER SEPTIC TANKWATERTIGHT WATERTIGHT 6' CRUSHED STONE BASE PROFILE: Nor TO SCALE _ r 1. N 9' MINIMUM COVER FIRST 2' TO BE LEVE126.9 4' PERF PIPE TEE7 4'VENT MIN 2x 1118`- ull 25 62 4' SOLID P 3 OUTLET 15?x 42' LEACH FIELD D -BOX MIN. 2' OF PEASTONE ts' 1 3� / 3/4' - 1 1/2' DIA. EXIST WASHED STONE GRADE INVERT ELEVATIONS: DESIGN CRI TER IA: INVERT AT BUILDING: 18.7 DESIGN FLOW: INVERT IN SEPTIC TANK: 18.5 4 BEDROOMS AT 110 G.P.D. PER INVERT OUT SEPTIC TANK: 18.25 BEDROOM EQUALS 440 G.P.D. INVERT IN PUMP CHAMBER: 18.15 INVERT OUT PUMP CHAMBER: 17.9 NO GARBAGE GRINDER INVERT IN DIST. BOX: 25.9 INVERT OUT DIST. BOX: 25.73 SEPTIC TANK REQUIRED: 440 G.P.D. X 2002 - 880 GAL, INVERT IN LEACH FIELD: 25.62 SEPTIC TANK PROVIDED: 1500 GAL. MIN. INVERT END `LEACH FIELD: 25.2 0. BOTTOM LEACH FIELD: 24.7 SOIL ABSORPTION SYSTEM REQUIRED: ADJUSTED GROUND WATER: 20.7 DESIGN PERC RATE ( 6 M1N/1NCH OBSERVED GROUND WATER: 20.6 SOIL TEXTURAL CLASS - I INDEX WELL SDW 252. ZONE A 25.8 EFFLUENT LOADING RATE - 0.70 GPD/SF MAY 98 READING -46.0'. ADJ-0.1' 440 GPD / 0.70 GPD/SF - 629 S.F. REQUIRED OBSERVED GROUNDWATER AT PERC HOLE A LOAMY IOYR PROVIDED: 15'x 42' LEACH FIELD. A-630 S.F. - ELEV 20.6 USED FOR DESIGN. IOYR 630 S.F. x 0.70 GPD/SF - 441 GPD SOIL TEST P I T DA TA 78-- 96'- 8' 96 17.8 144' 14.6 DATE: MAY 29. 1998 TEST BY: STEPHEN HAAS WITNESSED BY: ANY VONHONE PERC RATE: ( 6 MIN/INCH u 4 PLA/V OF LA/VZD 42 VESPER LANE YA RMO U OR r. "A . PREPAREo FOR : �IAMES BA SL ER BOX 356 . YARMOUTHPOR T. MA . 02675' SCAL E: / " - 30 ' -/U/VE- / 0. / 998 EAGLE SURVEYING, INC 923 Route 6A Yarmouthport MA. 02675 ( 508 ) 362-8132 ( 508 ) 432-5333 INDICATES INDICATES PERCOLATION _ OBSERVED TEST GROUNDWATER TP w/ TP #2 0. HORIZON TEXTURE COLOR HORIZON TEXTURE COLOR 25.8 0' 26.6 A LOAMY IOYR A LOAMY IOYR SAND 3/4 SAND 3/4 12 .......................................... 24.8 12 ' .......................................... 25.6 B LOAMY IOYR B LOAMY 10 YR SAND 4/6 SAND 4/6 24 .......................................... 23.6 24 ' .......................................... 24.6 C I SANDY IOYR C 1 SILT IOYR LOAM 5/4 LOAM 5/4 54' .......................................... 21.3 84 19.6 C2 FINE LOAMY IOYR SAND 5/6 65 ' 96 .......................................... 18.6 C2 FINE LOAMY IOYR SAND 5/6 78-- 96'- 8' 96 17.8 144' 14.6 DATE: MAY 29. 1998 TEST BY: STEPHEN HAAS WITNESSED BY: ANY VONHONE PERC RATE: ( 6 MIN/INCH u 4 PLA/V OF LA/VZD 42 VESPER LANE YA RMO U OR r. "A . PREPAREo FOR : �IAMES BA SL ER BOX 356 . YARMOUTHPOR T. MA . 02675' SCAL E: / " - 30 ' -/U/VE- / 0. / 998 EAGLE SURVEYING, INC 923 Route 6A Yarmouthport MA. 02675 ( 508 ) 362-8132 ( 508 ) 432-5333