Loading...
HomeMy WebLinkAbout16 Victory Lane - Septic Design 2DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-7 c �n cn yr LOAMY SAND 10YR3/1 NO 2 50 7-24 8 LOAMY SAND 1 1/8" TO 1/2" 24-120 C 4" CAST IRON PIPE 2.5Y7/4 35-60 C2 101.03 IA WASHED STONE VENT t (OR (OR EQUAL) MINIMUM C3 FINE SAND JOB No- 5965-00 TIGHT & 8.78 MIN. PITCH 1/4' PER FT, COMPACTED - LOCATION MAP REV. z ELEV. 97.53 ELEV.- RR 771� UN 98.03 m Q@ 20 P ELEV. ,c 98.75 SLAB ELEV. _ MN 1. p oeo 10' 0 +@3Z� ELEV. _ _93_50 LEVOEL 6' Slum o o ELEV. 96.70 _ --- i Q2 DISI 2 HIGH �ELEVj�ZSL_ (�{BUTION STONE INFIANRATORS 1 tLTpAyO�'� BOx �I��1 11' X 24' X 1W TRENCH FORVATION (TO BE PLACED ON FIRM BASE) V. 7Cp (TO BE WATER TESTED -gnll ARgnizp- ICIN b.07 L DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-7 Ap LOAMY SAND 10YR3/1 NO ROOTS 7-24 8 LOAMY SAND 10YR8/6 ROOTS 24-120 C MEDIUM SAND 2.5Y7/4 DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-6 A/'E MEDIUM SAND 10YR8/2 NO ROOTS 6-21 B LOAMY SAND 10YR6/ ROOTS 1-35 Cl - MEDIUM SAND 2.5Y8/2 35-60 C2 LOAMY SAND 2.5Y6/3. 0-12d C3 FINE SAND JOB No- 5965-00 TIGHT & COMPACTED ELEv. _ -- - --- - SINGULAR UV "THE DISINFECTOR" INC. 97.53 SYSTEM SAS i V mt LSD WATER ENCOUNTERED AT 95" ELEV. _ -M.g3 r-"' WATER ENCOUNTERED AT '- T19' ELEV. _X8993 ` PLANT (OR EQUAL) t SAMPLE CATCH AND ELEV. _ �9, 2D RECIRCULATING � A f l USGS PROBABLE WATER TABLE ELEV. _ f RECIRC�UL TING PUMP 3/4' TO 1 1/2" CLEAN OBSERVED WATER TABLE (6/24/04) ELEV. _ --"s3 WELL MIW DESIGN CALCULATIONS SEWAGE DISPOSAL, sSYSTEM PROFILE DOUBLE WASHED STONE BOTTOM OF TEST HOLE ELEV. _ �7z60 ZONE A FREE OF FINES &SILT 'INDEX 8.3_ NUMBER OF BEDROOMS �2_ NOT CALE ADJUST 1.7 GARBAGE DISPOSAL UNIT NO TOTAL ESTIMATEDLOW (110 GAL/bAY/BR. X 2 BR.) _2.20 GAL./DAY ' REQUIRED SEPTIC TANK CAPACITY 4_49- GAL. . ACTUAL SIZE OF SEPTIC TANK -M GAL SOIL CLASSIFICATION I _1 -- DESIGN PERCOLATION RATE <¢_ MIN./IN. EFFLUENT LOADING RATE -.0 j -f- GAL/DAY/S.F. LEACHING AREA -42233 SQ. FT. LEAiCHING CAPACITY (AREA X RATE) •238.2 GAL:/DAY 32233 X 0.74 14. VARIANCES TO TITLE 5 AND YARMOUTH REGULATIONS: RESERVE LEACHING CAPACITY •238.32 GAL/DAY A. SOIL ABSORPTION SYSTEM LESS THAN 10' FROM LOT LINE. B. SOIL ABSORPTION SYSTEM LESS THAN 20' FROM FOUNDATION. NOTES: C. SOIL ABSORPTION SYSTEM LESS THAN 100' FROM WETLAND: D. RESERVE AREA LESS THAN 10' FROM LOT LINE. 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. E. RESERVE AREA LESS THAN 20' FROM FOUNDATION. TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR F. RESERVE AREA LESS THAN 100' FROM WETLAND. THE SUBSURFACE DISPOSAL OF SEWAGE. G. SEPTIC TANK LESS THAN 100' FROM WETLAND. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO - WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF, THE SANITARY SYSTEM SHALL BE CAPBLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN �p 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE 63• . 97.7 USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4, ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL T - �_ L OT E� � ,....�,,. � ... _ . .....�_.:.. .. , ?ti_ut) f}O?FaAA �1DAT1f-1k HAS 4?cfN 9AAD�'.:AS TO C`l)FJPf f4Nf'!-'V�1Sr- N PLACE. oro T4FA11tENT1 '�"\ `"` DEEDED OR ZONING REGULATIONS. OWNER APPLICANT 1S TO OEL 9£CDN 1 By OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. �.\fiECIkCU1 ZINGMP { 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR \AND SA PLE, ATC 97.9 IS TO CALL 'DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS I°h 1 PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS 15:85' �I o EXISANC SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION OWEZLlNC IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER 50.00' r' 0 F�L R o 98.9 IMMEDIATELY. 112.99 ( W 1 i '` I 0 8. PARCEL IS IN FLOOD ZONES 8 & C d0. Ok- AS PARCEL 220 97. 88 9. LOT IS SHOWN ON O p 10. ALL UNSUITABLE MATERIAL SHALL BE RSMAP REMOVED FROM UNDER AND FOR I / t I`. / a p SOIL A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE REPLACED 11 / 93.7697 00' d 6.4 WETLAND o P. 5.7s 0. X WITH SAND AS SPECIFIED 1N 310 CMR 15.255:(3). o- cARA ///� 11. GUTTERS, DOWNSPOUTS, AND DRYWELLS REQUIRED. 97 D BUFFER ;N� e -- f yam. 4ZNCr •tT/ Oc,. 12. ALL DISTURBED AREAS ARE TO HE REVEGETATED. 13. ORK P J H 0 BE LACED PRIOR TO ANY EXCAVATION t /�,5� �r� otic HAYHALE W OMIT IS f ML VINYL «,C C i� �^A ON SITE. 0 `. 9U� i1P: I.. j oo, si SctJo.1C45� \ 9 - APPROVED: BOARD OF HEALTH LOT AREA I 11, 381.6 94. /1E� UPLAND 3SF 89.317,3101 DATE AGENT --L- S.F. 97.9g, I WETLAND 6,0755 f S, F. %r 1 50' • { -i �WE7LAND \ / BVW 4 BUfFER � f � 1 0 vtvArnw= rozao' 186• j/ it I 100.5 f 4k 96.5 , j 4 j / BVW s QS 96:2 / (� 4 I / BVW 6 / R LEGEND: / __(g6)--�� / iC�oi % EXISTING SPOT ELEVATION 00,0 r EXISTING CONTOUR ----00--- FINAL SPOT ELEVATION �0. +'35.7 -/ F FINAL CONTOUR- SOIL TEST LOCATION UTILITY POLE -0- ® 95.7 TOWN WATER WWW BVW J CATCH BASIN fa� GAS LINE i CLEAN OUT CESSPOOL C.P. C. `S8IPROJ{5965-00Idwpti5965-sbS.DKG 02004 SW'EETSER ENGINEERING LOCUS CLO\ z 0�� 28 30 Q PROPOSED SEPTIC DESIGN T110HASFOCOPJMLLY LOCATION 16 VICTORY LAM SOUTH' YAMAOUTH, HA 235 GREAT WESTERN ROAD 508- P. 0. SOX 713 SOTH DENNIS, MASS. U 398-3922 02660 DATESEPT. 8, 2004 SCALE _ 20' REV. OCT, 51 2004 JOB No- 5965-00 - LOCATION MAP REV. SHEET 1 OF 1 CESSPOOL C.P. C. `S8IPROJ{5965-00Idwpti5965-sbS.DKG 02004 SW'EETSER ENGINEERING