HomeMy WebLinkAbout9 Wasque Road - Septic DesignTOP OF FOUNDATION ELEV 193- 0 -\ Y 4' CAST IRON PIPE (OR EQUAL MINIMUM PITCH 1/4 PER FT. 4' SCHEDULE 40 PVC PIPE MIN. PITCH 1/8" PER FT. , SOIL TEST DATE OF SOIL TEST SEPT. 19, 1996 CLEAN SAND SOIL TEST DONE BY SWEETS R NGIN FRING WITNESSED BY P- BRYANTON LOAM AND SEED OBSERVATION HOLE 1 ELEv. Ip0 OBSERVATION HOLE 2 ELEV.- 2' LAYER OF PERCOLATION RATE G Z MIN./INCH AT (0 G INCHES PERCOLATION RATE -5 -_- MIN./INCH AT INCHES 1/8" TO 1/2- ASHED STONE °P NOTREQUIRED 1 CU. FT. OF CONCRETE / X7,5 o ANCHOR ELEV. = J u �AtiN. V. = 9 77S I_ 2 0" 10' ' J LEVEL 3 u ._ .' e ELEV. 9� i ELEV. r' BAFFLE Elft' - 57S 6' SU ELEV. _ DISTRIBUTION ELEV LIQUID OUTLET BOX 970 INFILTRATORS WITH STONE IN AN DEPTH TEE 4 FEET 14 INCHES (TO BE PLACED ON FIRM BASE) TO BE WATER TESTED DEPTH HORIZ TEXTURE COLOR MOTT. I OTHER 0-3 1914 L0�' toYwc 5�3.� 1' ' f S -2S T Logwly laYr" e� lip / JOB NO.'SLS U 3"lib1 REmSED SHEET 1 OF 1 yB�j 11 X 34 X 10 TRENCH FORMATION M 5 FEET 19 INCHES IF MORE THAN ONE OUTLET !2' 6 FEET 24 INCHES 1500 GALLON WELL /v A Aft, WATER ENCOUNTERED AT � ELEV. 7 FEET 29 INCHES (TO BE PLACED ON FIRM BASE) SOIL ABSORPTION IIT ZONE 8 FEET 34 INCHES SEPTIC TANK %\ 3/4' TO 1 1/2' SYSTEM (SAS) INDEX 41 WASHED STONE ; ADJUST r, LEGEND: USGS PROBABLE WATER TABLE ELEV. - EXISTING SPOT ELEVATION 00,0 SEWAGE DISPOSAL SYSTEM PROFILE OBSERVED WATER TABLE ( / / I) ELEV = EXISTING CONTOUR----00---- NOT TO SCALE BOTTOM OF TEST HOLE ELEV. = 1�Lr� FINAL SPOT ELEVATION 0.0 i P i C ! rn \ \ C.\ \ \ 12 v Q i i \ .� ti �\ \tib � +• X � at � \\ i ,\ \ \�\ of \ \\\ fl ct erYl 001 rN � I FINAL CONTOUR 00 SOIL TEST LOCATION UTILITY POLE . -0- TOWN WATER —WSW CATCH BASIN J GAS LINE G DEPTH HORIZ TEXTURE COLOR MOTT. OTHER Z D Lo,9," y 10y SWEETSER ENGINEERING 235 GREAT WESTERN ROAD 508— P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 I Z Z3 77 lip REVISED / L j>u JOB NO.'SLS U 3"lib1 REmSED SHEET 1 OF 1 yB�j 5,1,19 dO WATER 'ENCOUNTERED AT IZ6r ELEV a DESIGN CALCULATIONS NUMBER OF BEDROOMS_ GARBAGE DISPOSAL UNIT NO TOTAL ESTIMATED FLOW ( 110 GAL/BR./DAY X 3 SR.) 330 GAL/DAY REQUIRED SEPTIC TANK CAPACITY 660 GAL ACTUAL SIZE OF SEPTIC TANK 1500 GAL SOIL CLASSIFICATION I DESIGN PERCOLATION RATE < 5 M!N./IN. EFFLUENT LOADING RATE 0.74 GAL/DAY/S.F. LEACHING AREA 449.0 SQ. FT.- (11X34)+(45X2X10/l2) LEACHING CAPACITY (AREA X RATE) 332.26 GAL/DAY 449.0 X 0.74 RESERVE LEACHING CAPACITY 332.26 GAL/DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6' OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH OBTAIN SUCH L)MRMINAMON FROM APPRCPRIATE AUTHORITY. 6. UTILITIES SHOV,N ARE APPROtiMATT ONLY, EXCAVATION CONTRACTOR IS TO CALL 'DIG—SAFE' AT 1-800-322-4844 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. S. PARCEL IS IN FLOOD ZONE C. 9. LOT IS SHOWN ON ASSESSORS MAP 77 AS PARCEL J181 10. SEPTIC TANK AND DISTRIBUTION BOX ARE TO BE ON A 6" BED OF 3/4' TO 1 1/2 STONE OR ON MECHANICALLY COMPACTED NATURALLY OCCURRING SAND. APPROVED: BOARD OF HEALTH /1�cls DATE AGENT BEAcoN s�E p0Ly0CK 1tl? ROAO LOCUS TO s n Tq� o — 'GF REGIONAL a m a PROPOSED SEPTIC DESIGN .J �0�1E5 RSR,��'�t% PROJECT LOCATION LOT 181 9 WASQUE ROAD, S.Y. SWEETSER ENGINEERING 235 GREAT WESTERN ROAD 508— P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 SCALE 1 = ZO a DATE DEGt�N R �� 1598 REVISED / L j>u JOB NO.'SLS U LOCATION'. MAP REmSED SHEET 1 OF 1