HomeMy WebLinkAbout353 Weir Road - Septic DesignTOP OF FOUNDATION HORIZ IV ri. minim Vin "Vin V'_" 97.00 10 FT, MINIMUM 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE ELEV. = _ LOAMY SAND 10187/2 NO COBBLES 5-18 CONCRETE LOAMY SAND 10YR7/4 NO COVERS 4" SCHEDULE 40 PVC PIPE Cl LOAMY SAND 2.5Y7/1 MIN. PITCH 1/8" PER FT. 3.70 4" CAST IRON PIPE 6 MA AX 2.5Y6/1 MUM EQUAL)1/4 OI COBBLES 120-132 C2 II CHPER PFT. 2.5Y6/1 LOCATION MAP REVISED i FLOW LINE ELEV.93.30 _ 10" -TMIN. _ i LEV. _ _9280 -. , L2E,QL� ELEV. _ _93.45_ GAS ELEV. 92.60 6" SUMP ELEV. 92_43__ BAFFLE DISTRIBUTION _ LIQUID OUTLETELEV. BOX 9� -/ QFPTH 4 FEET 14 INCHESWATER (TO BE PLACED ON FIRM BASE) TO BE TESTED 5 FEET 19 INCHESIF 1 500 GALLON MORE THAN ONE OUTLET 6 FEET 7 FEET 24 INCHES 29 INCHES SEPTIC TANK (TO BE PLACED ON FIRM BASE) 8 FEET 34 INCHES 3/4" TO 1 1/2" CLEAN -/ DOUBLE WASHED STONE FREE OF FINES & SILT CLEAN SAND INSPECTION PORT LOAM AND SEED XW,93.68 " LAYER OF " D 1/2"MAX. ASHED STONE MIN. 0 0 j H16H CAPAdTYhVRLTRA TORS NTH IN AN jjX 36' X 10 ' TRENCH FORM SOIL ABSORP11ON SYSTEM (SAS) NOTREQUIRED m ELEV. = 93_00 le e ELEV. 91.80 40 ML ?NE z VINYL 5.00 LINER WATER ENCOUNTERED AT �y0= ELEV. _ _ 85 3 ELEV. - 89.00 SOIL TEST DATE OF SOIL TEST JULY 7. 2005 SOIL TEST DONE BY SWUTSER ENGINEERING WITNESSED BY A. VQN_fflLNL 013SMA110N HOLE 1 ELEV.= 92_80 OgSMATION HOLE 2 ELEV.= 91.80 PERCOLATION RATE _5_1_ MIN./INCH AT 57 INCHES PERCOLATION RATE < _ MIN./INCH IN Cl HORIZON DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-6 A LOAMY SAND 10187/2 NO COBBLES 5-18 B LOAMY SAND 10YR7/4 NO COBBLES 18-84 Cl LOAMY SAND 2.5Y7/1 (i1X36)+(47X2X10/12) COBBLES 84-126 C2 SANDY LOAM 2.5Y6/1 RESERVE LEACHING CAPACITY COBBLES t, USGS PROBABLE WATER TABLE ELEV. _ _tl6_Q_ WELL A1W 247 SEWAGE DISPOSAL SYSTEM PROFILE OBSERVED WATER TABLE (7/7/05) ELEV. _ _85.'.0- ZONE 8 NOT TO SCALE BOTTOM OF TEST HOLE ELEV @0,812 INDEX 220 J� 49 �P 4� 1),t� 928 S01 94.3\ L •� o�P�kc /5.0 �\\ / 50' BUFF£! ADJUST 1.3__ 01 F 88.1 /ice/ Bo, 16. l 5• \ / G ' / • as.6 // .A LO --- NK " � /�Y/J p8.87.4 87.1 ell Lei 94.L / CoQ s1.7 L �oq / JJ u i 94. 0 Q C f 0 J i /88.4/ �95,1 WLF 11' 7 89.9 \ \�9�� / J 2v i I /88.2 /_ }MLF 12 J I A88 \\\ WLF �O ! I g4) 92.9 J i J116g�a 87.0 89.6 \ \ AC77V£ WLF 9490.6 /i // �, \\ // \\\ CRANBERRY --BOC WLF 8 97-8 X17.63 ACRES f \\\\ LEGEND: \\1� � i \ • 9o.4J \\ EXISTING SPOT ELEVATION 00■0 WLF \7\ 97 l 91.1 / / EXISTING CONTOUR ----00---- FINAL SPOT ELEVATION 00. FINAL CONTOUR 0 / /- SOIL TEST LOCATION \ \ / UTILITY POLE -Q p0,� \ \ TOWN WATER -WSW 091.2 7` WLF Al CATCH BASIN \®/ \ 91.4 - )O GAS LINE G - /NACi7l£ WLF 6 \ // F 1;1/ 8 2 \ \ \ •--'87.1 CESSPOOL O C.P. CRANBERRY -BOC \ / / 87�g 9.8 / CLEANOUT O.O. IVLF A2 \ L 8330 _ WLF A3 88.6 -- .89.8 --------------- \ / / � WLF 3 WV 2 OF T. A. DUMAS No. 619 DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-72 FILL _�3Q_ GAL./DAY REQUIRED SEPTIC TANK CAPACITY X80_ GAL. 72-75 A LOAMY SAND 10YR3/1 NO COBBLES 75-90 B LOAMY SAND IOYR4/4 (i1X36)+(47X2X10/12) COBBLES 90-120 Cl MEDIUM SAND 2.5Y7/4 RESERVE LEACHING CAPACITY COBBLES 120-132 C2 SANDY LOAM 2.5Y6/1 LOCATION MAP WATER ENCOUNTERED AT 78" ELEV. _ _85 30. DESIGN CALCULA11ONS NUMBER OF BEDROOMS 3 GARBAGE DISPOSAL UNIT TOTAL ESTIMATED FLOW ( 110 GAL/BR./IDAY X 3 BR.) _�3Q_ GAL./DAY REQUIRED SEPTIC TANK CAPACITY X80_ GAL. ACTUAL SIZE OF SEPTIC TANK 1500 GAL. SOIL CLASSIFICATION I DESIGN PERCOLATION RATE 5-30_ MIN./IN. EFFLUENT LOADING RATE 57.7 GAL/DAY/S.F. LEACHING AREA 474`33 SO. FT. (i1X36)+(47X2X10/12) LEACHING CAPACITY (AREA X RATE) J5tDQ GAL./DAY - 474.33 X 0.74 REVISED RESERVE LEACHING CAPACITY MIM GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWNS RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6. OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. I 8. PARCEL IS IN FLOOD ZONE 0 117 3 9. LOT IS SHOWN ON ASSESSORS MAP 126 AS PARCEL 40 , 10. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE REPLACED WITH SAND AS SPECIFIED IN 310 CMR 15.255:(3). 11. ALL DISTURBED AREAS ARE TO BE STABILIZED AND REVEGETATED. 12. VARIANCES TO TITLE 5 AND YARMOUTH REGULATIONS: A. SOIL ABSORPTION SYSTEM LESS THAN 10' FROM LOT LINE. B. SOIL ABSORPTION SYSTEM LESS THAN 20' FROM FOUNDATION. C. SOIL ABSORPTION SYSTEM LESS THAN 100' FROM WETLAND. D. RESERVE AREA LESS THAN 10' FROM LOT LINE. E. RESERVE AREA LESS THAN 100' FROM WETLAND. APPROVED: BOARD OF HEALTH DATE AGENT WOR ROAD ' � cU5 2 a � PROPOSED SEPTIC DESIGN FOR TOM GRET'T LOG. 353 W1 EIR ROAD YARMOUTH, MASS, Si MM? ERNGIN�ERING 235 GREAT WESTERN ROAD 508- P. 0. BOX 713 SOUTH DENNIS, MASS. 398-3922 02660 =JULY LY 20, 20051 SCALE 1" = 20' JOB NO. 6119-00 REVISED LOCATION MAP REVISED i SHEET 1 OF 1