Loading...
HomeMy WebLinkAbout395 Weir Road - Septic Design 3TOP OF FOUNDATION ELEV. - 10275 - 10 F 4' CAST IRON PIPE -' (OR EOUAL� MINIMUM PITCH 1/4 PER FT. FLOW LINE _ 1 -ELEV. -TM p i LEV. .97.75 ' LEVOEL� ELEV. -$Q GAS ELEV. 97.6p 6' SU P ELEV. 97.43 BAFFLE DISTRIBUTION ELEV. a (TO BE PLACED ON FIRM BASE) BOX TO BE WATER TESTED 1+500 GALLON IF MORE THAN ONE OUTLET SEPTIC TANK (TO BE PLACED ON FIRM BASE) 3/4' TO 1 1/2' CLEAN -1 DOUBLE WASHED STONE FREE OF FINES do SILT SEWAGE DISPOSAL SYSTEM PROFILE NOT TO SCALE 20 'FT. MI 10 FT. MINIMUM F A CONCRETE COVERS FROM CELLAR - SdiL TEST AS OR CRAWL SPACE DATE OF SOIL TEST MAY 29,_2002 CLEAN SAND SOIL TEST DONE BY ��ER ENGINE RING INSPECTION PORT WITNESSED BY A. VONHONE 103.00 4' SCHEDULE 40 PVC PIPE LOAM AND SEED OBSERVATION HOLE 1 ELEV.- OBSERVATION HOLE 2 ELEV.- 100.30 MIN. PITCH 1/8' PER FT, , 2' LAYER OF PERCOLATION RATE < 2 MIN./INCH AT 69 INCHES PERCOLATION RATE < 2 MIN Amrw iN n A, r� unonnu 1/8' TO 1/2- D.80 MAX. WASHED STONE VENT 1EN• NOT REQUIRED 9 1 CU. FT. OF _ CONCRETE 97.80 a ANCHOR a . 10' ECFV. a 98.47 4 HIGH CAPACITY INFILTRATORS WITH STONE IN AN 1 . 0„ HORIZ TEXTURE COLOR MOTT. i 0-14 A LOAMY SAND 10YR2/1 NO ROOTS 14-32 92 LOAMY SAND 10YR5/B 20% - - 32-46 (96) m LOAMY SAND 7.5YR5/8 20% - 46-120 Cl �NM?Aa T x' 2.5Y7/3 71 u EXISTING SPOT ELEVATION 00„0 NUMBER OF BEDROOMS'' p�1 WEIR BROAD 5LY WIErLAN OBSERVED WATER TABLE ( / / ) ELEV. - A EXISTING CONTOUR ----00---- GARBAGE DISPOSAL UNIT : NQ_ BOTTOM OF TEST HOLE ELEV. - _M3Q FINAL SPOT ELEVATION TOTAL ESTIMATED FLOW FINAL CONTOUR-- ( 110 GAL/BR./DAY'X _ 3_ BR.) _MQ -GAL./DAY `,80.95'/ SOIL TEST LOCATION (9 REQUIRED SEPTIC TANK CAPACITY / �•` 99.2 \ I GR,1 UTILITY POLE -0- ACTUAL SIZE OF SEPTIC TANK 1500 GAL - - TOWN WATER -W-W SOIL CLASSIFICATION 97.5 i Q 7.4 DESIGN PERCOLATION RATE EFFLUENT LOADING RATE 101, 3 98.1 CLEAN OUT \ (AeB 96.7 / CESSPOOL C.P. Q N 7. V 3 1 '.7 fGp' wERAND 9u r£R .4 25.74' 6X34 P C y; N I .1¢0.8 k 103 3 I I PROPO .D � 3 SEOROO 4 t ORYWELL DNE'LLINC 1500 SfPT/C C� a o � t $ j4\ 1 99. 98 j 647 L)FFEF �iLAf � .50 i B"- (98; 98.0 1. S/L T FEN E y8 \ MRK uM/r q \ I A 95.4 100.00 6RAM WAY 1 G " 94.5 f-9 41 l94 . .g / - f41 - DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-14 A LOAMY SAND 10YR2/1 NO ROOTS 14-32 81 LOAMY SAND 10YR5/B 20% COBBLES 32-46 82 LOAMY SAND 7.5YR5/8 20% COBBLES 46-120 Cl COURSE SAND 2.5Y7/3 USGS PROBABLE WATER TABLE ELEV. a DEPTH HORIZ I i TEXTURE COLOR I MOTT. OTHER 0-12 A LOAMY SAND 10YR2/2 NO ROOTS 12-25 B7 LOAMY SAND 10YR5/8 ROOTS 25-54 Cl MEDIUM SAND 10YR6/8 54-120 C2 MEDIUM SAND 2.5Y6/2 USGS PROBABLE WATER TABLE ELEV. a 1 X38 X 1 TRENCH FORMATION _ W C, a RRs ' ReeK LN. WEIR ROAD IA!iU5 PROPOSED SEPTIC DESIGN FOR JOSH GREpi SOIL ABSORPTION "' WELL N/A NO WATER ENCOUNTERED AT 120' ELEV.'- _ 9100 NO WATER ENCOUNTERED AT _190_ ELEV. - _gnm PROJECT LOCATION LOT 4 IJV 395 HEIR ROAD, YARMOUTH SYSTEM (SAS) ZONE INDEX SR DfGflVEVWG 235 ,GREAT WESTERN ROAD 508- I P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 ADJUST SCALE 1„ _ 20 REV."JULY 17, 12002 LEGEND: DESIGN CALCULATIONS USGS PROBABLE WATER TABLE ELEV. a EXISTING SPOT ELEVATION 00„0 NUMBER OF BEDROOMS'' 3 f7SHEET 1 OF 1 OBSERVED WATER TABLE ( / / ) ELEV. - EXISTING CONTOUR ----00---- GARBAGE DISPOSAL UNIT : NQ_ BOTTOM OF TEST HOLE ELEV. - _M3Q FINAL SPOT ELEVATION TOTAL ESTIMATED FLOW FINAL CONTOUR-- ( 110 GAL/BR./DAY'X _ 3_ BR.) _MQ -GAL./DAY SOIL TEST LOCATION (9 REQUIRED SEPTIC TANK CAPACITY 900_ GAL. UTILITY POLE -0- ACTUAL SIZE OF SEPTIC TANK 1500 GAL - - TOWN WATER -W-W SOIL CLASSIFICATION CATCH BASIN /®\ GAS LINE DESIGN PERCOLATION RATE EFFLUENT LOADING RATE 5.,.1?` MIN./IN. DJA GAL/DAY/S.F. CLEAN OUT LEACHING AREA i 474.33 SO. FT. / CESSPOOL C.P. Q (11X36)h(47X2X10/12) J�� � B9• ARE'A+16,1941 Sr. ` / T � OLE 1 R£S€6 00' c. / R£SfR 7 / J ,c� • / j� .705.7 ���. 105.1 1j tr • 104.2 \ \ 1654 5 � 96 2 94, 9 -,tea �• 94.6 LEACHING CAPACITY (AREA X RATE) MLOO GAL./DAY 474.33 X 0.74 RESERVE LEACHING CAPACITY IM.OQ GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN OF _Y/WQUII'L- RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6' OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. - 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH - DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR. IS TO CALL 'DIG -SAFE' AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING (WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR.ITO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. 8. PARCEL IS IN FLOOD ZONE G 9. LOT IS SHOWN ON ASSESSORS MAP 126 AS PARCEL 38 10. A SILT FENCE WORK LIMIT IS TO BE INSTALLED PRIOR TO COMMENCING ANY WORK ON SITE. 11. GUTTER, DOWNSPOUTS AND DRYWELL ARE REQUIRED. 12. ALL DISTURBED AREAS ARE TO BE REVEGETATED. 13. VARIANCES TO YARMOUTH REGULATIONS: A. SOIL ABSORBTION SYSTEM LESS THAN 100 AWAY FROM WETLAND: B. RESERVE AREA LESS THAN 100' FROM WETLAND 14. IN THE EVENT OF FAILURE OF THE PRIMARY SAS, IT IS TO BE REMOVED, RE -EXCAVATED, AND CLEANED THE REPLACED IN SAME POSITION. APPROVED: BOARD OF HEALTH DATE AGENT _ W C, a RRs ' ReeK LN. WEIR ROAD IA!iU5 PROPOSED SEPTIC DESIGN FOR JOSH GREpi PROJECT LOCATION LOT 4 IJV 395 HEIR ROAD, YARMOUTH SR DfGflVEVWG 235 ,GREAT WESTERN ROAD 508- I P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 DATE JUNE 20, I2002� SCALE 1„ _ 20 REV."JULY 17, 12002 NO. 5413-00 LOCATION MAP REV. jI f7SHEET 1 OF 1