Loading...
HomeMy WebLinkAbout395 Weir Road - Septic Design 4MEMMM TOP OF FOUNDATION ELEV. _ 100.00� (ASSUMED) ;�l A 10 FT i 20 FT. MINIMUM FROM CELLAR SOIL. TEST 001 INIMUM 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE SOILETTEST DONE BY �'ti'EETS OF SOIL TEST R ENGINEERING CLEAN SAND CONCRETE WITNESSED BY A. VONHONE COVERS INSPECTION PORT a = 1a3a OBSERVATION HOLE 1 ELEV.- = 4" SCHEDULE 40 PVC PIPE LOAM AND SEED OBSERVATION HOLE 2 ELEV.= 100.30 MIN. PITCH 1/8" PER FT, 2" LAYER OF PERCOLATION RATE < 2 MIN.ANCH AT 69 INCHES PERCOLATION RATE :9 2 MIN./INCH IN C1,& C2 HORIZON. DEPTH HORIZ TEXTURE COLOR 1/8" TO 1/2- OTHER 0 4' CAST IRON PIPE X 10YR2/1 X MAX WAS' ED TONE. VENT (OR EQUAL) MINIMUM 81 LOAMY SAND 10YR5/8 20% NOT REQUIRED PITCH 1/4" PER FT. 82 LOAMY SAND 7.5YR5/8 z 1 CU. FT. OF 46-120 Cl COURSE SAND 2.5Y7/3 m CONCRETE C2 FLOW LINE 2.5Y6/2 xo ANCHOR ELEV. - 9700— U 10" MiN. LOCATION MAP SHEET 1 OF -1 ELEV. 98-45 _ 20' LEVEL = s 10� ° ELEV. _ _$QIQ_ GAS ELEV. = 6 " SUMP X ELEV: _ _ o _ ° - - -� ELEV. _ X BAFFLE DISTRIBUTION 1QUID OUTLET ELEV. _ V 4 HIGH CAPACITY INFILTRATORS WITH �EPTH TEE FI (TO BE PLACED ON FIRM BASE) BOX — x STONE IN AN Z FEET 14 INCHES TO BE WATER TESTED cr if DEPTH HORIZ TEXTURE COLOR A DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-14 A LOAMY SAND 10YR2/1 NO ROOTS 14-32 81 LOAMY SAND 10YR5/8 20% COBBLES 32-46 82 LOAMY SAND 7.5YR5/8 207. COBBLES 46-120 Cl COURSE SAND 2.5Y7/3 JOB N0, 5,13---00 54-120 DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-12 AI LOAMY SAND IOYR2/2 NO ROOTS 12-25 81 LOAMY SAND 10YR5/8 ROOTS 25-54 Cl MEDIUM SAND 10Y R6/6 JOB N0, 5,13---00 54-120 C2 MEDIUM SAND 2.5Y6/2 t,. 1500 GALLON IF MORE THAN ONE OUTLET it x o6- x tv IKLNt,'H tUHMAIION I . -- I - > NO WATER ENCOUNTERED AT 170_ ELEV. = 91 NO WATER ENCOUNTERED AT 120 ELEV. _ _90,30 J SEPTIC TANK (TO BE PLACED ON FIRM BASE)-SOILLCABSORPTION ZONE N/A 3/4" TO 1 1 /2" CLEAN SYSTEM J�li� /SAS INDEX DOUBLE WASHED STONE \ ADJUST FREE OF FINES & SILT LEGEND: DESIGN CALCULATIONS SEWAGE DISPOSAL SYSTEM PROFILE OBSERVED PROBABLE WATER TABLE ELEV: = - EXISTING SPOT ELEVATION 00„0 NUMBER OF BEDROOMS 3 _ NOT TO SCALE OBSERVED WATER TABLE ( / / ) ELEV. +_ EXISTING CONTOUR ----00---- GARBAGE DISPOSAL UNIT BOTTOM OF TEST HOLE ELEV. _ x FINAL SPOT ELEVATION TOTAL ESTIMATED FLOW FINAL CONTOUR-- Q ( 110 GAL/BR./DAY X _.i_ BR.) __MQ_ GAL/DAY SOIL TEST LOCATION REQUIRED SEPTIC TANK CAPACITY -J-5Q— GAL UTILITY POLE ACTUAL SIZE OF SEPTIC TANK 1500 GAL TOWN WATER —W—W SOIL CLASSIFICATION =j— CATCH BASIN fig\ DESIGN PERCOLATION RATE ��— MIN./IN. GAS UNE EFFLUENT LOADING RATE GAL/DAY/S.F. CLEAN OUT CS LEACHING AREA 3 SQ. FT, CESSPOOL C.P. O (11X36}4(47X2X10/12) LEACHING CAPACITY (AREA X RATE) 1"=12 GAL/DAY 474.33 X 0.74 +_-- -- RESERVE LEACHINGCAPACITY *IMQQ GAL./DAY .-.- - _ -- --- NOTES: ----" -�� 1. ALL WORKMANSHIPAND MATERIALS SHALL CONFORM TO D.E.P. -- --- ercvuvTW8Mr / _ _ _ TITLE 5 AND THE TOWN OF __,Y>MOUTH RULES AND {nttsra).ROAD` REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. YVL _ 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO AVEMENT__ -- WITHIN 6 OF FINISHED GRADE. _ ---' 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF +�~WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN STONf WALL 10 "FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE 80.95' USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. L- 5. �� tOL = 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL AREA=76,1941 SF. - BE MORTARED IN PLACE. - /. _ - 5. NO DETERMINA11ON HAS BEEN MADE AS TO COMPLIANCE WITH' - pRDID �? DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO ` L OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 00' 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR 11. .� DRIVE \ p I pr 11 T1� IS TO CALL "DIG -SAFE' AT 1-888-344-7233 AT LEAST 72 HOURS YF`. '[E AO! P 1 I PRIOR TO COMMENCING WORK ON SITE. HOLE 1 T01�h,f�.I I, (K 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS �V _ SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER 26.00 IMMEDIATELY. 3 r ° 2112 MI 27 AM I',0 23 B. PARCEL IS IN FLOOD ZONE C 9. LOT IS SHOWN ON ASSESSORS MAP 126 PARCEL 38 - . _ AS 20.96' _.. I -' HDL£ 2 o - _6X34 FORC GRAVEL WAY °J ` 0 'All PROPOSED x 3 BEDROOM DWELLING tytH OF44�Yn .. R ` - 1500 GALLON APPROVED: BOARD OF HEALTH TANK SEP AC DATE AGENT C.• �S8yPROJl5413-00 �dwg�5413-OO.DWG ppF�r�Vr'ti ve-r1 UTt3tn,st9iT` c OY.k1ft�a� SWEETSER ENGINEER NG PROPOSED SEPTIC DESIGN ' FOR - TOM GRET PROJECT LOCATION A LOT VEER ROAD, YARMOUTH aSVEMM? 235 GREAT WESTERN ROAD 508— P. 0. BOX 713 398-3922 SOUTH DENNIS, MASS. 02660 DATE JUNE 3, 2002 scALE 1 » = 20' JOB N0, 5,13---00 REVISED LOCATION MAP 7sED SHEET 1 OF -1 C.• �S8yPROJl5413-00 �dwg�5413-OO.DWG 02002 SWEETSER ENGINEER NG