HomeMy WebLinkAbout78 Wendward Way - Septic Design- N - q,. g4 v ACCESS COVERS MUST BE WITHIN MINIMUM, 7 NVER T 'ELEVATIONS : DES ! GN CR I TER /A : GENERAL NOTES 6' QF,FINlSH GRADE 3 MAXIMUM CO VER DESIGN FLOW: Y FIRST 2' TO INVERT AT BUILDING: _I0!-2s 1 3 MIN 2' OF P£ASTONE INVERT IN SEPTIC TANK: Ip0-0 4 BEDROOMS AT !f0 G.P.O. PER 1. THIS PLAN f5 FOR THE DESIGN AND CONSTRUCTION o BE LEVEL OF THE SEWAGE"DISPOSAL SYSTEM ONLY. r OR FILTER FABRIC.' INVERT OUT SEPTIC TANK: oo-7S BEDROOM EQUALS 440 G.P.D. IAM ♦ 3/4' - ! 'I/?' DIA. INVERT !N DIST.' SOX: 00.47 - 2.- VERTICAL DATUM /S ASSLIbfD. FOR BENCH MARKS INVERT OUT DIST. BOX., SET. NO GARBAGE GRINDER o ? . eo DOUBLE WASHED STONE SET. Sff 5I TE PLAN. ` GAS INVERT /N LEACH CHAMBER. -99.2 SEPTIC TANK REQUIRED: 4 - BAFFL - r 4-500 GAL LEACHING CHAMBERS BOTTOM OF LEACH CHAMBER: 97.2 440.G.P.O. X ?OOx - 880 GAL. J. ALL CONSTRUCTION METHODS AND MATERIALS AND 3 OUTLET ADJUSTED GROUND WATER: N/A M4INTENANCE OF THE SEPTIC SYSTEM SHALL T 0 BOX W/2' STONE AROUND. 8.8'r x 46'1 x 2'd SEPTIC TANX PROVIDED: 1500 GAL. MIN. 1500 GAL OBSERVED GROUND WATER: N/A CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL SEPTIC TANK 6' CRUSHED STONE OR BOTTOM OF TEST JfOLf •!: 91.0 SOIL ABSORPTION SYSTEM REQUIRED: BOARD OF HEALTH REGULATIONS. ._ COMPACTED BASE DESIGN FERC RATE f 5 MIN/INCH r SOIL TEXTURAL CLASS - I 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER PROF I L E : NOT TO SCALE EFFLUENT LOADING RATE - 0.74 GPD/SF AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER 440 'GPO / 0.74 GPD/SF - 595 S.F. REQUIRED THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- 440 H-20 WHEEL LOADS, W/2VISTONE4AROUNDGAL A1624EACHS NG CHAMBERS 5. ALL SEWER PIPE SHALL 8E SCHEDULE 40 PVC OR / 624 S.F. x 0.74 - 462 G.P.D. APPROVED EQUAL: 6. SEPTIC TANK AND D-BOX SHALL BE REINFORCED SOIL TEST P1 T DA TA & Pii CONCRETE OR APPROVED POLYETHYLENE. ..< BOTH SHALL BE WATERTIGHT. D-BOX SHALL BE WATER S 89.19'50'£ S%OCKACF ii Ct < INDICATES INDICATES sL1r dA.L ante PERCOLATION — OBSERVED GROUNDWATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE' 4 r TEST OUTLET. r6'OAK. 111 91 .. `.,oma - 48 � TP •! 7 BEFORE CONSTRUCTION CALL-DlG-SAFE% k e W 1-888-DIG-SAFE AND THE LOCAL WATER DEPT. • o W O. HORIZON TEXTURE COLOR 101.5 FOR LOCATION OF UNDERGROUND UTILITIES. LOAMY IOYR -so0 wuoN D e0x ' ors i Y { 'Q SAND 3/4 8. SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE a LEACH NO CHAMBERS TP.J '{" , o - I �L ... ............. /00.8 012' STONE ARO" Z- � 9' DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION R -, / `we LOAMY IOYR 1 8 OF THE SYSTEM TO ALLOW FOR SCHEDULING OF THE _rA �L'�' SAND 4/6 e CONSTRUCTION INSPECTIONS. ls0o w11oN r 'x!4"'/'28' .................... 99.2 - a oa rs • li SEPTJC TANK Ir" ° `rte � JLMED I UM / OYR C / SAND 6/6 9. EXISTING CESSPOOL TO BE PUMPED DRY AND L , BEDROOM. BEDROOM t„� - BACKFILLED. B{cq� .�' BM-CORNER SNOr R ORA VEL EL•JOS.77 BATHi 10. ALL UNSUITABLE MATERIAL IA 6 B HORIZONS) + CESSPOOL 10: 7 r- 40 ENCOUNTERED BELOW F THE INVERT OF THE LEACHING l uvJNO s810H`fnD FACILITY TO B£ REMOVED FOR A DISTANCE OF 5' c -. .. KITCHEN / _.----=---- .:,. ... __. .. " —AROUND AND:REPLACED WITH SAND IN-ACCORDdNCE� o W_ - ,o . -.�� o _ _ Wf TH TITLE S. o o. v,5 o BEDROOM o v 126' NO WATER 91.0 W DATE: DECEMBER 1, 2011 z TEST BY: STEPHEN HAAS f1 WITNESSED BY: AMY VONHONE v<.o Ce,1•fwar PERC RATE C 2 MIN/INCH Al LOT 43 .,- 15.250' S.F. /t FILE COPY SEP T I C S YS TEM DES l GIV 41, A' i 78 WENOWARD WAY. MAP 36. PARCEL -1 23 „A iiNCE _ 1A1 �5' �7OCKADf rE TOWN OF YARMOUTH S Q9' I9'5O'E REVIEWED FOR BUILDING AND ZONING CODE COME SIT YARMOUTH. MA. ANC£. ERRORS OR OM^AISSIONS QO NOT RELIEVE APPLICANT FROM THE RESPONSIQ LITj' OF 'AS BUILT" ,- EPWR'O t r w� a¢ a �-.,,. �, � ..•> - :.. , :. ' - 'COMP r- W� RUSS CARON gI: LEGEND eul QI iclAl .� Rove s 13 :LAKELAND AVE SOUTH YARMOUTH MA 02664 _ —wW CB CONCRETE BOUND — WATER L rNE SCALE : / 20 DECEMBER 20. 20 1 1 � O HYDRANT , -G— GASL/Ns EAGLE SURVEY I NG INC OVER WAD WIRES RES OHW--^ 923 F2oute 6A CU LIGHT POST �_�_ Yarmouthport. MA. 02675 --E-- UNDERGROUND ELECTRIC UNE , ` (508) 362-8132 -T— UNDERGROUND TELEPHONE LINE \�. : (508 432-5333 —CTV— UNDERGROUND C48LEVISION LINE �1�1 4-40.4 SPOT ELEVATION J Y ........40....... EXISTING CONTOUR Gips PROPOSED CONTOUR L OCUS MAP o IO 20 40 JOB N0: '1 /-138 FIELD:CFW/D TW CALC: SAH/CFW CHECK: CFW ORN: SAH'