HomeMy WebLinkAbout78 Wendward Way - Septic Design 2I ACCESS COVERS MUST BE WI 6. OF FINISH GRADE IQ3 83 FIRST 2' TO z n BE LEVEL 9• MINIMUM. 3' MAXIMUM COVER MIN 2' OF PEASTONE OR FILTER FABRIC 3/4' = 1 1/2- DIA. U \0 0 3 a1O �2' �= DOUBLE WASHED STONE BAs BAFFLE- 47 i 3 OUTLET 4-500 GAL LEACHING CHAMBERS D -BOX W/2' STONE AROUND. 8.8'r x 46'1 x 2'd 1500 GAL SEPTIC TANK 6- CRUSHED STONE OR COMPACTED BASE PROF I L E : NOT TO SCALE INVERT EL E VA T I ONS INVERT AT BUILDING: 10/.25 INVERT IN SEPTIC TANK: 100.0 INVERT OUT SEPTIC TANK: 99.75 INVERT IN DIST. BOX: 99.47 INVERT OUT DIST, BOX: 99.3 INVERT IN LEACH CHAMBER., 99.2 BOTTOM OF LEACH CHAMBER: 97.2 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE sl: 91.0 N DES I GN CR I TER I A : GENERAL NOTES: DESIGN FLOW: COLOR A LOAMY IOYR 4 BEDROOMS AT 110 G.P.D. PER I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION BEDROOM EQUALS 440 G.P.D. 9' OF'I THE SEWAGE DISPOSAL SYSTEM ONLY. NO GARBAGE GRINDER Z. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS B LOAMY SET. SEE SITE PLAN. SEPTIC TANK REQUIRED: SAND 440 G.P.O. X 200x - 880 GAL. J. ALL CONSTRUCTION METHODS AND MATERIALS AND SEPTIC TANK PROVIDED. 1500 GAL. MIN. MAINTENANCE OF THE SEPTIC SYSTEM SHALL C I MEDIUM CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL SOIL ABSORPTION SYSTEM REQUIRED: BOARD OF HEALTH REGULATIONS, DESIGN PERC RATE ( 5 MIN/INCH GRAVEL SOIL TEXTURAL CLASS - 1 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER EFFLUENT LOADING RATE - 0.74 GPD/SF AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER 440 GPD / 0.74 GPD/SF - 595 S.F. REQUIRED THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. PROVIDED: 4-500 GAL LEACHING CHAMBERS W/2' STONE AROUND. A-624 S.F, 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR 624 S.F. x 0.74 - 462 G.P.D. APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED SOIL TES T PIT DA TA & PRECAST CONCRETE OR APPROVED POLYETHYLENE. 807H SHALL BE WATERTIGHT. D -BOX SHALL BE WATER INDICATES INDICATES PERCOLATION_ OBSERVED TESTED FOR LEVEL WHEN THERE 1S MORE THAN ONE TEST GROUNDWATER OUTLET. TP •I 0- HORIZON TEXTURE COLOR A LOAMY IOYR SAND 3/4 9' B LOAMY IOYR SAND 4/6 26 -----------•-------- C I MEDIUM IOYR SAND 6/6 GRAVEL 40 126= DATE: DECEMBER 1. 2011 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: ( 2 MIN/INCH 7. BEFORE CONSTRUCTION CALL DIG -SAFE . 1 -1888 -DIG -SAFE AND THE LOCAL WATER DEPT. 101.5 FOR LOCATION OF UNDERGROUND UTILITIES. 100.8 8. SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION OF THE SYSTEM TO ALLOW FOR SCHEDULING OF THE 99.2 CONSTRUCTION INSPECTIONS. 9. EXISTING CESSPOOL TO BE PUMPED DRY AND BACKFILLED. 10. ALL UNSUITABLE MATERIAL (A 6 8 HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED W17H SAND IN ACCORDANCE I Ti4 TITLE S. RECEIVED 91.0 IM 02 N33 BUILDING DEPARTMENT ByTA3rI�'Ar 1i