Loading...
HomeMy WebLinkAbout170 Wendward Way - Plot Plan 2a FIzz F LOCUS SEC❑ND RD, I LOCUS MAP NOT TO SCALE LOCUS INFORMATION RICHARD CLARKE OVERLAY DISTRICT: SARAYA CLARKE NITROGEN SENSITIVE CERT. 177253 ZONE: 19724—B, SH -1 FEMA FLOOD 29 9 R-25 FRONT 30' SIDE 15' REAR 20' 1C 0 '.0 ."'3 ttiOZ �1"�� NOTE: � SEPTIC LOCATION IS APPROXIMATE AND IS GF a BASED ON A 2005 AS -BUILT PLAN ON FILE AT THE YARMOUTH BOARD OF HEALTH. FIN Eg LOT 8 IN C4x 561'30 00"W 99.14 EXISTING SEPTIC SYSTEM i OHW z ((\ \ o O00 \ \ \ \ Q \\ W, GATE W GATE \ \ s� 1 I I 1 LOT 14 w ZONE DISTRICT: MINIMUM LOT SIZE: EXISTING LOT SIZE: FORMER LOT COVERAGE: NEW LOT COVERAGE: MAXIMUM COVERAGE ALLOWED: EXISTING DECK #170 EXISTINO ONE STORY DWELLING NEW 10'x16' FRAME OVER 5 10" SONO TUBES EXISTING DECK �a ?s a N813000"E 60.00 NONE NOT A ZONE II V, DATED 7/2/1992 PANEL #250015 0005 D 25,000 MAIN STREET 28 CURRENT OWNER: TITLE REFERENCE: 9,773± S.F. w 1,745± S.F. (17.867.) 1,720* 3 (17.60 PLAN REFERENCE: S.F. (25.005) VP PROFESSIONAL LAND SURVEYOR DATE z a QPM ASSESSORS MAP: SONO TUBE 3 AT PARCEL: as r a w FIRST RD, N ZONING DISTRICT: 0 0 3 _ I SETBACKS: FIzz F LOCUS SEC❑ND RD, I LOCUS MAP NOT TO SCALE LOCUS INFORMATION RICHARD CLARKE OVERLAY DISTRICT: SARAYA CLARKE NITROGEN SENSITIVE CERT. 177253 ZONE: 19724—B, SH -1 FEMA FLOOD 29 9 R-25 FRONT 30' SIDE 15' REAR 20' 1C 0 '.0 ."'3 ttiOZ �1"�� NOTE: � SEPTIC LOCATION IS APPROXIMATE AND IS GF a BASED ON A 2005 AS -BUILT PLAN ON FILE AT THE YARMOUTH BOARD OF HEALTH. FIN Eg LOT 8 IN C4x 561'30 00"W 99.14 EXISTING SEPTIC SYSTEM i OHW z ((\ \ o O00 \ \ \ \ Q \\ W, GATE W GATE \ \ s� 1 I I 1 LOT 14 w ZONE DISTRICT: MINIMUM LOT SIZE: EXISTING LOT SIZE: FORMER LOT COVERAGE: NEW LOT COVERAGE: MAXIMUM COVERAGE ALLOWED: EXISTING DECK #170 EXISTINO ONE STORY DWELLING NEW 10'x16' FRAME OVER 5 10" SONO TUBES EXISTING DECK �a ?s a N813000"E 60.00 NONE NOT A ZONE II V, DATED 7/2/1992 PANEL #250015 0005 D 25,000 S.F. I CERTIFY TO THE BEST OF MY 9,773± S.F. DIMENSIONS AND SETBACKS TO THE 1,745± S.F. (17.867.) 1,720* S.F. (17.60 2,443± S.F. (25.005) LOT 9 3 BIG FOOT FOOTINGS UNDER 10" SONO TUBES LOT 15 0 IS PROPOSED 36"x36' LANDING HATH A 1'_ STEP ROAD r V _ \ Foundation Location Approved 1 G _ , 17 �,t2 REVISIONS: NO. DATE DESC. I CERTIFY TO THE BEST OF MY PROFESSIONAL KNOWLEDGE, INFORMATION AND BELIEF THAT THE LOT CORNERS, DIMENSIONS AND SETBACKS TO THE STRUCTURE AS DETERMINED BY INSTRUMENT SURVEY AND AS SHOWN ON THIS PLAN ARE CORRECT. YV �OF�Oy CRAIG A �r F! tf N0.36039 PROFESSIONAL LAND SURVEYOR DATE CERTIFIED PLOT PLAN WITH NEW SONO TUBE FOUNDATION AT #170 WENDWARD WAY IN WEST YARMOUTH MASSACHUSETTS (BARNSTABLE COUNTY) APRIL 18, 2011 PREPARED FOR: PATIO ENCLOSURES, INC. Mr. RICHARD GEARY 500 MILES STANDISH BLVD. TAUNTON, MA 02780 508-822-1966 RICH.GEARY®PATIOENC.COM x BSC GROUP 349 Route 28,Unit D West Yarmouth, Massachusetts 02673 508 778 8919 © 2011 The BSC Group, Inc. SCALE: 10 - 10' 0 1.25 2.5 5 Mins 0 5 10.,.. 20 m7 PROD. MGR.: CRAIG FIELD FIELD: P. HAGIST CALC./DESIGN: K. HEALY DRAWN: K. HEALY CHECK: CRAIG FIELD LFILE:9459-ABF.DWG 6032-02SHEET 1 OF 1 4-9549.00