HomeMy WebLinkAbout362 Willow Street General Plan 320"0 CLEANOUT
(TYP.)
FINISHED GRADE
6'-2"( 4"0 PVC FROM
' BUILDING
4'-10"
6" f
24"0 CAST IRON FRAME
AND COVER WITH PRE -CAST
CONCRETE RISER (H20 LOADING).
SET FLUSH WITH GRADE. (TYP. OF 2)
BIOTUBE EFFLUENT
FILTER
GAS BAFFLE
I 12" AIR (GB1 BY TUF-TITE
i SPACE r OR EQUAL)
3/4" CRUSHED
STONE BED
TANK INTERIOR IS 5'-0" WIDE
TANK EXTERIOR IS 6'-0" WIDE
1,500 GALLON SEPTIC TANK (H20
SCALE: 1/2' -l' -O"
4"0 PVC
INLET TEE
B" MIN.
6" 1
PLAN VIEW
4'-7"
7"
NOTES
1. D -BOX OUTLET LINES SHALL BE LEVEL FOR A
MINIMUM OF THE FIRST TWO FEET OF THEIR
LENGTH AND SHALL THEREAFTER HAVE A MINIMUM
SLOPE OF 0.005.
2. D -BOX SHALL BE SET LEVEL ON 3/4" STONE
BASE. CHECK BY FILLING D -BOX WITH WATER AND
VERIFYING THAT ALL OUTLETS ARE AT THE SAME
4" WALL ELEVATION. ADJUST AS NECESSARY.
THICKNESS 3. D -BOX SHALL BE PRODUCT #DB -7-20 OR
DB -9-20 BY CaASE PRECAST CORP.
NORTHBROOKFIELD MA, OR APPROVED EQUAL.
4. PROVIDE SPEED LEVELERS SL -4 (BY TUF-TITE
OR EQUAL) ON ALL D -BOX OUTLET PIPES.
(7) OUTLET W/
4" DIA. PVC SEAL
7 -OUTLET D -BOX (1-120)
SCALE: 1"=l' -O"
WATERTIGHT COVER
-'J
7"
SECTION A -A
SCALE: 1 "=1'-0" K-2
4"0 PVC
OUTLET LINE
(TYP. FOR 2)
2'-4"
3/4" CRUSHED
STONE BED
EL. 96.20'
EL. 88.12'
EL. 82.20'
GW EL. 76.20'
EL. 95.00'
EL. 86.08'
EL. 79.67'
GW EL. 75.00'
NOTES:
1. SOIL EVALUATION WAS CONDUCTED ON 09/18/01 BY DAN SAULNIER, SEA CONSULTANTS.
2. THE PERCOLATION RATE IS EQUAL TO 2 MINUTES PER INCH.
3. THE EFFLUENT LOADING RATE PER 310 CMR 15.242 IS EQUAL TO 0.74 GPD/SF.
4. WITNESS FOR THE DEPARTMENT OF ENVIRONMENTAL PROTECTION WAS MR. BRIAN DUDLEY.
DEEP OBSERVATION HOLE LOG 2
DEEP OBSERVATION
HOLE LOG 1
Depth from
Sail Horizon
Soil Texture
Soil Color
Soil Mottling
Other
Surface (inches)
(Mune ll)
(USDA)
(Munsell)
(Structure, Stones, Boulders, Consistency, X
FLEXIBLE MANHOLE SLEEVE (TYP.)
THICKNESSSlt
Gravel)
0 to 83
Gravel)
0 to 74
Fill
Med. Sand
Some Cobbles
Some color
Some Boulders
12" MIN OF 3/4"
Cbserved
around organics
A
74 to 78
A
Loamy Sand
5YR 2.5/1
None
Massive, firm
Loamy Sand
IOYR 5/6
Observed
Massive, very friable, no gravel
Observed
Ci
78 to 97
B
Loamy Sand
10YR 5/6
None
Massive, very friable, no gravel
Med. Sand
2 5Y 5/4
None
Observed
Massive, loose, trace silt, trace gravel
Observed
C3
97 to 168
C
Medium-
IOYR 6/6
None
Massive) structureless, 4% fine gravel,
Coarse Sand
Observed
trace silt, pockets of fine -medium sand
Percolation Hole Shelf at 97"
Percolation Rate < 2 MPI
ESTIMATED SEASONAL HIGH GROUND WATER
TADLE AT 240" BASED ON MONITORING WELL DATA.
NOTES:
1. SOIL EVALUATION WAS CONDUCTED ON 09/18/01 BY DAN SAULNIER, SEA CONSULTANTS.
2. THE PERCOLATION RATE IS EQUAL TO 2 MINUTES PER INCH.
3. THE EFFLUENT LOADING RATE PER 310 CMR 15.242 IS EQUAL TO 0.74 GPD/SF.
4. WITNESS FOR THE DEPARTMENT OF ENVIRONMENTAL PROTECTION WAS MR. BRIAN DUDLEY.
DEEP OBSERVATION HOLE LOG 2
Depth from
Soil Horizon
Soil Texture
Soil Calor
Sol Mottling
Other
Surface (inches)
(USDA)
(Mune ll)
(Structure, Stones, Boulders, Consistency, X
'
FLEXIBLE MANHOLE SLEEVE (TYP.)
THICKNESSSlt
Gravel)
0 to 83
Fill
Med. Sand
None
Some Cobbles
;'
12" MIN OF 3/4"
Cbserved
83 to 93
A
Loamy Sand
5YR 2.5/1
NoneObserved
Massive, firm
93 to 107
B
Loamy Sand
IOYR 5/6
Observed
Massive, very friable, no gravel
107 to 133
Ci
Medium-
Coarse Sand
2 5Y 5 4
/
None
Observed
Massive, loose, 4% fine ravel
g
133 to 159
C2
Med. Sand
2 5Y 5/4
None
Observed
Massive, loose, trace silt, trace gravel
159 to 184
C3
Medium-
Coarse Sand
2,5Y 6 6
/
None
Observed
Massive, loose, 4% fine ravel
A
ESTIMATED SEASONAL HIGH GROUND WATER TABLE AT 240" BASED ON MONITORING WELL DATA.
NOTES:
1. SOIL EVALUATION WAS CONDUCTED ON 09/18/01 BY DAN SAULNIER, SEA CONSULTANTS.
2. THE PERCOLATION RATE IS EQUAL TO 2 MINUTES PER INCH.
3. THE EFFLUENT LOADING RATE PER 310 CMR 15.242 IS EQUAL TO 0.74 GPD/SF.
4. WITNESS FOR THE DEPARTMENT OF ENVIRONMENTAL PROTECTION WAS MR. BRIAN DUDLEY.
I certify that on April 1999 (date) I have passed the soil evaluator
examination approved by the Department of Environmental Protection and that
the above analysis was performed by me consistent with the required training
expertise and experience described in 310 CMR -15.017.
a
Signature &4
PLACE JOINT OR COUPLING
PVC GRAVITY SEK
(SIZE VARIES)
POLYPROPYLENE COATED
STEPS SAFETY TYPE
STANDARD 30"0 M
FRAME & COVER
TYPICAL MANHOLE (PLAN)
INVERT
FLEXIBLE MANHOLE
SLEEVE (TYP.)
SMOOTH ROUNDED
FOR ALL SIDE
JCE PIPES
YARMOUTH
MAINTENANCE FACILITY
Design Criteria STATE FEDAID PROJ.NO. FISCAL SHEET TOTAL
FED.
AID Building 15 employees YEAR NO. SHEETS
(Industrial Plant without Cafeteria) 125gpd/employee gpd MASS NSA 03 16 17
Site is located within a Designated Zone 2 PROJECT FILE NO. 601571
Maximum Wastewater Loading <440 gpd/acre
Acreage of property 10 acres GENERAL PLAN
22.5 gpd/acre
Total Design Flow of System = 225 gpd
Title 5 Soil Class I Sand, LoamySand
Percolation rate 2 mpi
Title 5 Loading Rate = 0.74 gpd/sf
Sizing Septic Tank
Total required volume 450 gallons
Use minimum allowable volume 1,500 gallons
Size Leach Area
Leaching Area Design Flow 225 gpd
Required Leaching Area 304 sf
Select Leaching Trenches, Number 2 trenches
Width of Trenches 2 it
Effective Depth of Trenches 2 ft TOPSOIL
Length of Trenches 30 ft
Sidewall Area 240 sf
Bottom Area 120 sr
Total Leaching Area 360 sf COMMON FILL
Leaching Capacity Provided 266 gpd 4" MIN
1/8" TO 1/2"
Buoyancy Calculation DOUBLE -WASHED
1,500 gallon septic tank " " PEA STONE
Weight of tank 23,500 # 8 MIN. 2
Width of tank 6.00 R
Length of tank 11.00 It
.tom.
Height of tank 6.17 it
Area of tank 66 sq it
Volume of Tank 407 cu ft "X60;` 4"0 PVC WITH 3/8"0
Ground elevation 95.80 ft
Groundwater elevation 95.80 It I ORIFICES LOCATED 45'
Elevation of tank top 94.2.7 It OFF VERTICAL, ON
Elevation of tank bottom 88.10 ft
Weight, displaced water 1 25,411 # 2'-D" ALTERNATING SIDES,
12" ON CENTER.
Buoyant Weight of Soil Above Tank 5,816# EFFECTIVE
Weight of Tank & Buoyant Weight of Soil 29,316 # DEPTH 3/4" TO 1 1 /2" INCH
Additional weight needed NONE
DOUBLE -WASHED STONE
=``
7 -outlet distribution box =�FREE OF IRON, FINES AND DUST
Weight of tank 1,050 # 1 4%
Width of tank 1.67 it
Length of tank 2.67 it
Height of tank 2.33 ft
Area of tank 4.5 sq it
Volume of Tank 10.4 cu it
Ground elevation 94.60 it 2'-0"
Groundwater elevation 94.80 it WIDTH
Elevation of tank top 93.12 it
Elevation of tank bottom 90.79 ft
Weight, displaced water 6480
Buoyant Weight of Soil Above Tank 431 #
Weight of Tank & Buoyant Weight of Soil 1,481 #
Additional weight needed NONE
SET CASTING IN GROUT
AND GROUT ALL AROUND
COAT WITH (2) COATS OF
BITUMAS71C
STEEL REINFORCED TO '
A.S.T.M. & A.A.S.H.T.O.
SPECS. 0.12 SQ. IN -/LIN. FT.
BUM RUBBER JOINT (TYP.)
SEAL ALL PINHOLES WITH
HYDRAULIC CEMENT \ ,'
MANHOLE STEPS 0 12" O.C.
LEACHING TRENCH DETAIL
SCALE: 1" = 1'-0"
STANDARD MANHOLE
FRAME & COVER
SET RIM AT
FINISH GRADE
USE BRICK COURSES AS
NEEDED TO BRING MANHOLE
RIM TO REQUIRED ELEVATION
i (MAX HEIGHT 10")
SEAL INSIDE & OUTSIDE
WITH HYDRAULIC CEMENT
" MIN
STANDARD PRECAST CONE
SECTION IN 2, 3' & 4'
LENGTHS WITH FLAT OR
CONICAL TOP
5" WWII`
STANDARD PRECAST BARREL
' SECTION COMBINATIONS OF
1', 2', 3' OR 4' LENGTHS
AS NEEDED TO BRING
MANHOLE RIM TO REQUIRED
-0" MINIMUM ELEVATION
SEAL ALL JOINTS WITH
HYDRAULIC CEMENT
- -V
` p
N�
N
BRICK TABLE (SEE NOTES)
`\'i-
STANDARD PRECAST BASE
'
IN 3' LENGTH
6" MIN BOTTOM SLAB
'
FLEXIBLE MANHOLE SLEEVE (TYP.)
THICKNESSSlt
---
;'
12" MIN OF 3/4"
\ ,
NOTES:
CRUSHED STONE
`
1. INNER EDGE OF BRICK TABLE
TO BE AT ELEV OF CROWN OF
TOP OF PIPE. TABLE TO SLOPE
AT 1" PER 1' TO INSIDE_ OF
MANHOLE BASE
2- TYPICAL SANITARY MANHOLE
TYPICAL
MANHOLE (ELEVATION)
TO BE 4 FT. DIA.
IILT.&